Feasibility and Accuracy of Thoracolumbar Minimally Invasive Pedicle Screw Placement With Augmented Reality Navigation Technology

被引:92
作者
Elmi-Terander, Adrian [1 ]
Nachabe, Rami [2 ]
Skulason, Halldor [1 ]
Pedersen, Kyrre [1 ]
Soderman, Michael [1 ]
Racadio, John [2 ]
Babic, Drazenko [3 ]
Gerdhem, Paul [4 ]
Edstrom, Erik [1 ]
机构
[1] Karolinska Hosp, Dept Neuroradiol, Stockholm, Sweden
[2] Philips Healthcare, Image Guided Therapy Syst, Best, Netherlands
[3] Cincinnati Childrens Hosp, Dept Radiol, Cincinnati, OH USA
[4] Karolinska Hosp, Dept Orthoped, Stockholm, Sweden
基金
欧盟地平线“2020”;
关键词
accuracy; augmented reality; hybrid operating room; integrated navigation; minimally invasive pedicle screw; occupational radiation dose; SURGICAL NAVIGATION; RADIATION-EXPOSURE; LUMBAR SPINE; SURGERY; FUSION;
D O I
10.1097/BRS.0000000000002502
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Cadaveric laboratory study. Objective. To assess the feasibility and accuracy of minimally invasive thoracolumbar pedicle screw placement using augmented reality (AR) surgical navigation. Summary of Background Data. Minimally invasive spine (MIS) surgery has increasingly become the method of choice for a wide variety of spine pathologies. Navigation technology based on AR has been shown to be feasible, accurate, and safe in open procedures. AR technology may also be used for MIS surgery. Methods. The AR surgical navigation was installed in a hybrid operating room (OR). The hybrid OR includes a surgical table, a motorized flat detector C-arm with intraoperative 2D/3D imaging capabilities, integrated optical cameras for AR navigation, and patient motion tracking using optical markers on the skin. Navigation and screw placement was without any x-ray guidance. Two neurosurgeons placed 66 Jamshidi needles (two cadavers) and 18 cannulated pedicle screws (one cadaver) in the thoracolumbar spine. Technical accuracy was evaluated by measuring the distance between the tip of the actual needle position and the corresponding planned path as well as the angles between the needle and the desired path. Time needed for navigation along the virtual planned path was measured. An independent reviewer assessed the postoperative scans for the pedicle screws' clinical accuracy. Results. Navigation time per insertion was 90 +/- 53 seconds with an accuracy of 2.2 +/- 1.3 mm. Accuracy was not dependent on operator. There was no correlation between navigation time and accuracy. The mean error angle between the Jamshidi needles and planned paths was 0.98 +/- 0.88. No screw was misplaced outside the pedicle. Two screws breached 2 to 4mm yielding an overall accuracy of 89% (16/18). Conclusion. MIS screw placement directed by AR with intraoperative 3D imaging in a hybrid OR is accurate and efficient, without any fluoroscopy or x-ray imaging during the procedure.
引用
收藏
页码:1018 / 1023
页数:6
相关论文
共 21 条
[1]   Improved Accuracy of Minimally Invasive Transpedicular Screw Placement in the Lumbar Spine With 3-Dimensional Stereotactic Image Guidance A Comparative Meta-Analysis [J].
Bourgeois, Austin C. ;
Faulkner, Austin R. ;
Bradley, Yong C. ;
Pasciak, Alexander S. ;
Barlow, Patrick B. ;
Gash, Judson R. ;
Reid, William S. .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2015, 28 (09) :324-329
[2]   Comparison between percutaneous and traditional fixation of lumbar spine fracture: Intraoperative radiation exposure levels and outcomes [J].
Bronsard, N. ;
Boli, T. ;
Challali, M. ;
de Dompsure, R. ;
Amoretti, N. ;
Padovani, B. ;
Bruneton, G. ;
Fuchs, A. ;
de Peretti, F. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2013, 99 (02) :162-168
[3]   Economic evaluation comparing intraoperative cone beam CT-based navigation and conventional fluoroscopy for the placement of spinal pedicle screws: a patient-level data cost-effectiveness analysis [J].
Dea, Nicolas ;
Fisher, Charles G. ;
Batke, Juliet ;
Strelzow, Jason ;
Mendelsohn, Daniel ;
Paquette, Scott J. ;
Kwon, Brian K. ;
Boyd, Michael D. ;
Dvorak, Marcel F. S. ;
Street, John T. .
SPINE JOURNAL, 2016, 16 (01) :23-31
[4]   Surgical Navigation Technology Based on Augmented Reality and Integrated 3D Intraoperative Imaging: A Spine Cadaveric Feasibility and Accuracy Study [J].
Elmi-Terander, Adrian ;
Skulason, Halldor ;
Soderman, Michael ;
Racadio, John ;
Homan, Robert ;
Babic, Drazenko ;
van der Vaart, Nijs ;
Nachabe, Rami .
SPINE, 2016, 41 (21) :E1303-E1311
[5]   ACCURACY OF PEDICULAR SCREW PLACEMENT INVIVO [J].
GERTZBEIN, SD ;
ROBBINS, SE .
SPINE, 1990, 15 (01) :11-14
[6]   Perioperative outcomes and adverse events of minimally invasive versus open posterior lumbar fusion: meta-analysis and systematic review [J].
Goldstein, Christina L. ;
Macwan, Kevin ;
Sundararajan, Kala ;
Rampersaud, Y. Raja .
JOURNAL OF NEUROSURGERY-SPINE, 2016, 24 (03) :416-427
[7]   Spinal intraoperative three-dimensional navigation: correlation between clinical and absolute engineering accuracy [J].
Guha, Daipayan ;
Jakubovic, Raphael ;
Gupta, Shaurya ;
Alotaibi, Naif M. ;
Cadotte, David ;
da Costa, Leodante B. ;
George, Rajeesh ;
Heyn, Chris ;
Howard, Peter ;
Kapadia, Anish ;
Klostranec, Jesse M. ;
Phan, Nicolas ;
Tan, Gamaliel ;
Mainprize, Todd G. ;
Yee, Albert ;
Yang, Victor X. D. .
SPINE JOURNAL, 2017, 17 (04) :489-498
[8]   Factors affecting the accurate placement of percutaneous pedicle screws during minimally invasive transforaminal lumbar interbody fusion [J].
Kim, Moon-Chan ;
Chung, Hung-Tae ;
Cho, Jae-Lim ;
Kim, Dong-Jun ;
Chung, Nam-Su .
EUROPEAN SPINE JOURNAL, 2011, 20 (10) :1635-1643
[9]   A new 3-dimensional method for measuring precision in surgical navigation and methods to optimize navigation accuracy [J].
Kleck, Christopher J. ;
Cullilmore, Ian ;
LaFleur, Matthew ;
Lindley, Emily ;
Rentschler, Mark E. ;
Burger, Evalina L. ;
Cain, Christopher M. J. ;
Patel, Vikas V. .
EUROPEAN SPINE JOURNAL, 2016, 25 (06) :1764-1774
[10]   Total 3D Airo® Navigation for Minimally Invasive Transforaminal Lumbar Interbody Fusion [J].
Lian, Xiaofeng ;
Navarro-Ramirez, Rodrigo ;
Berlin, Connor ;
Jada, Ajit ;
Moriguchi, Yu ;
Zhang, Qiwei ;
Hartl, Roger .
BIOMED RESEARCH INTERNATIONAL, 2016, 2016