Control of an Ambulatory Exoskeleton with a Brain-Machine Interface for Spinal Cord Injury Gait Rehabilitation

被引:92
|
作者
Lopez-Larraz, Eduardo [1 ,2 ]
Trincado-Alonso, Fernando [3 ]
Rajasekaran, Vijaykumar [4 ]
Perez-Nombela, Soraya [3 ]
del-Ama, Antonio J. [3 ]
Aranda, Joan [4 ]
Minguez, Javier [1 ,2 ,5 ]
Gil-Agudo, Angel [3 ]
Montesano, Luis [1 ,2 ]
机构
[1] Univ Zaragoza, Dept Informat & Ingn Sistemas, Zaragoza, Spain
[2] Inst Invest Ingn Aragon I3A, Zaragoza, Spain
[3] Natl Hosp Spinal Cord Injury, Biomech & Tech Aids Unit, Toledo, Spain
[4] Univ Politecn Cataluna, Inst Bioengn Catalunya, Barcelona, Spain
[5] Bit & Brain Technol, Zaragoza, Spain
关键词
spinal cord injury (SCI); brain machine interfaces (BMI); ambulatory exoskeletons; gait rehabilitation; movement intention decoding; electroencephalography (EEG); event related desynchronization (ERD); movement related cortical potentials (MRCP); COMPUTER INTERFACE; EEG; WALKING; RELIABILITY; MOVEMENTS; INTENTION; VALIDITY; CORTEX; SCALE;
D O I
10.3389/fnins.2016.00359
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The closed-loop control of rehabilitative technologies by neural commands has shown a great potential to improve motor recovery in patients suffering from paralysis. Brain-machine interfaces (BMI) can be used as a natural control method for such technologies. BMI provides a continuous association between the brain activity and peripheral stimulation, with the potential to induce plastic changes in the nervous system. Paraplegic patients, and especially the ones with incomplete injuries, constitute a potential target population to be rehabilitated with brain-controlled robotic systems, as they may improve their gait function after the reinforcement of their spared intact neural pathways. This paper proposes a closed-loop BMI system to control an ambulatory exoskeleton without any weight or balance support for gait rehabilitation of incomplete spinal cord injury (SCI) patients. The integrated system was validated with three healthy subjects, and its viability in a clinical scenario was tested with four SCI patients. Using a cue-guided paradigm, the electroencephalographic signals of the subjects were used to decode their gait intention and to trigger the movements of the exoskeleton. We designed a protocol with a special emphasis on safety, as patients with poor balance were required to stand and walk. We continuously monitored their fatigue and exertion level, and conducted usability and user-satisfaction tests after the experiments. The results show that, for the three healthy subjects, 84.44 +/- 14.56% of the trials were correctly decoded. Three out of four patients performed at least one successful BMI session, with an average performance of 77.6 1 +/- 14.72%. The shared control strategy implemented (i.e., the exoskeleton could only move during specific periods of time) was effective in preventing unexpected movements during periods in which patients were asked to relax. On average, 55.22 +/- 16.69% and 40.45 +/- 16.98% of the trials (for healthy subjects and patients, respectively) would have suffered from unexpected activations (i.e., false positives) without the proposed control strategy. All the patients showed low exertion and fatigue levels during the performance of the experiments. This paper constitutes a proof-of-concept study to validate the feasibility of a BMI to control an ambulatory exoskeleton by patients with incomplete paraplegia (i.e., patients with good prognosis for gait rehabilitation).
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Future developments in brain-machine interface research
    Lebedev, Mikhail A.
    Tate, Andrew J.
    Hanson, Timothy L.
    Li, Zheng
    O'Doherty, Joseph E.
    Winans, Jesse A.
    Ifft, Peter J.
    Zhuang, Katie Z.
    Fitzsimmons, Nathan A.
    Schwarz, David A.
    Fuller, Andrew M.
    An, Je Hi
    Nicolelis, Miguel A. L.
    CLINICS, 2011, 66 : 25 - 32
  • [42] Volition-adaptive control for gait training using wearable exoskeleton: preliminary tests with incomplete spinal cord injury individuals
    Rajasekaran, Vijaykumar
    Lopez-Larraz, Eduardo
    Trincado-Alonso, Fernando
    Aranda, Joan
    Montesano, Luis
    del-Ama, Antonio J.
    Pons, Jose L.
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2018, 15
  • [43] The development of brain-machine interface neuroprosthetic devices
    Parag G. Patil
    Dennis A. Turner
    Neurotherapeutics, 2008, 5 : 137 - 146
  • [44] Assistive powered exoskeleton for complete spinal cord injury: correlations between walking ability and exoskeleton control
    Guanziroli, Eleonora
    Cazzaniga, Maurizio
    Colombo, Laura
    Basilico, Sabrina
    Legnani, Giovanni
    Molteni, Franco
    EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2019, 55 (02) : 209 - 216
  • [45] The development of brain-machine interface neuroprosthetic devices
    Patil, Parag G.
    Turner, Dennis A.
    NEUROTHERAPEUTICS, 2008, 5 (01) : 137 - 146
  • [46] Patent landscape of brain-machine interface technology
    Greenberg, Anastasia
    Cohen, Alexis
    Grewal, Monica
    NATURE BIOTECHNOLOGY, 2021, 39 (10) : 1194 - 1199
  • [47] Shared Control of an Intelligent Wheelchair with Dynamic Constraints Using Brain-Machine Interface
    Li, Z.
    Yang, C.
    Zhao, S.
    Wang, N.
    Su, C. -Y.
    INTELLIGENT ROBOTICS AND APPLICATIONS (ICIRA 2015), PT II, 2015, 9245 : 260 - 271
  • [48] System Identification of Brain-Machine Interface Control Using a Cursor Jump Perturbation
    Stavisky, Sergey D.
    Kao, Jonathan C.
    Sorokin, Jordan M.
    Ryu, Stephen I.
    Shenoy, Krishna V.
    2015 7TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER), 2015, : 643 - 647
  • [49] Walking with and without a robotic exoskeleton in people with incomplete spinal cord injury compared to a typical gait pattern
    Almutairi, Sattam
    Swank, Chad
    Wang-Price, Sharon
    Gao, Fan
    Medley, Ann
    NEUROREHABILITATION, 2021, 49 (04) : 585 - 596
  • [50] Modular Control of Gait in Incomplete Spinal Cord Injury: Preliminary Results
    Perez-Nombela, Soraya
    Barroso, Filipe
    Torricelli, Diego
    Gomez Soriano, Julio
    de los Reyes-Guzman, Ana
    del-Ama, Antonio J.
    Luis Pons, Jose
    Gil-Agudo, Angel
    REPLACE, REPAIR, RESTORE, RELIEVE - BRIDGING CLINICAL AND ENGINEERING SOLUTIONS IN NEUROREHABILITATION, 2014, 7 : 601 - 610