Control of an Ambulatory Exoskeleton with a Brain-Machine Interface for Spinal Cord Injury Gait Rehabilitation

被引:92
|
作者
Lopez-Larraz, Eduardo [1 ,2 ]
Trincado-Alonso, Fernando [3 ]
Rajasekaran, Vijaykumar [4 ]
Perez-Nombela, Soraya [3 ]
del-Ama, Antonio J. [3 ]
Aranda, Joan [4 ]
Minguez, Javier [1 ,2 ,5 ]
Gil-Agudo, Angel [3 ]
Montesano, Luis [1 ,2 ]
机构
[1] Univ Zaragoza, Dept Informat & Ingn Sistemas, Zaragoza, Spain
[2] Inst Invest Ingn Aragon I3A, Zaragoza, Spain
[3] Natl Hosp Spinal Cord Injury, Biomech & Tech Aids Unit, Toledo, Spain
[4] Univ Politecn Cataluna, Inst Bioengn Catalunya, Barcelona, Spain
[5] Bit & Brain Technol, Zaragoza, Spain
关键词
spinal cord injury (SCI); brain machine interfaces (BMI); ambulatory exoskeletons; gait rehabilitation; movement intention decoding; electroencephalography (EEG); event related desynchronization (ERD); movement related cortical potentials (MRCP); COMPUTER INTERFACE; EEG; WALKING; RELIABILITY; MOVEMENTS; INTENTION; VALIDITY; CORTEX; SCALE;
D O I
10.3389/fnins.2016.00359
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The closed-loop control of rehabilitative technologies by neural commands has shown a great potential to improve motor recovery in patients suffering from paralysis. Brain-machine interfaces (BMI) can be used as a natural control method for such technologies. BMI provides a continuous association between the brain activity and peripheral stimulation, with the potential to induce plastic changes in the nervous system. Paraplegic patients, and especially the ones with incomplete injuries, constitute a potential target population to be rehabilitated with brain-controlled robotic systems, as they may improve their gait function after the reinforcement of their spared intact neural pathways. This paper proposes a closed-loop BMI system to control an ambulatory exoskeleton without any weight or balance support for gait rehabilitation of incomplete spinal cord injury (SCI) patients. The integrated system was validated with three healthy subjects, and its viability in a clinical scenario was tested with four SCI patients. Using a cue-guided paradigm, the electroencephalographic signals of the subjects were used to decode their gait intention and to trigger the movements of the exoskeleton. We designed a protocol with a special emphasis on safety, as patients with poor balance were required to stand and walk. We continuously monitored their fatigue and exertion level, and conducted usability and user-satisfaction tests after the experiments. The results show that, for the three healthy subjects, 84.44 +/- 14.56% of the trials were correctly decoded. Three out of four patients performed at least one successful BMI session, with an average performance of 77.6 1 +/- 14.72%. The shared control strategy implemented (i.e., the exoskeleton could only move during specific periods of time) was effective in preventing unexpected movements during periods in which patients were asked to relax. On average, 55.22 +/- 16.69% and 40.45 +/- 16.98% of the trials (for healthy subjects and patients, respectively) would have suffered from unexpected activations (i.e., false positives) without the proposed control strategy. All the patients showed low exertion and fatigue levels during the performance of the experiments. This paper constitutes a proof-of-concept study to validate the feasibility of a BMI to control an ambulatory exoskeleton by patients with incomplete paraplegia (i.e., patients with good prognosis for gait rehabilitation).
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Gait robot-assisted rehabilitation in persons with spinal cord injury: A scoping review
    Stampacchia, Giulia
    Gazzotti, Valeria
    Olivieri, Matteo
    Andrenelli, Elisa
    Bonaiuti, Donatella
    Calabro, Rocco Salvatore
    Carmignano, Simona Maria
    Cassio, Anna
    Fundaro, Cira
    Companini, Isabella
    Mazzoli, David
    Cerulli, Simona
    Chisari, Carmelo
    Colombo, Valentina
    Dalise, Stefania
    Mazzoleni, Daniele
    Melegari, Corrado
    Merlo, Andrea
    Boldrini, Paolo
    Mazzoleni, Stefano
    Posteraro, Federico
    Mazzucchelli, Miriam
    Benanti, Paolo
    Castelli, Enrico
    Draicchio, Francesco
    Falabella, Vincenzo
    Galeri, Silvia
    Gimigliano, Francesca
    Grigioni, Mauro
    Mazzon, Stefano
    Molteni, Franco
    Morone, Giovanni
    Petrarca, Maurizio
    Picelli, Alessandro
    Senatore, Michele
    Turchetti, Giuseppe
    Bizzarrini, Emiliana
    NEUROREHABILITATION, 2022, 51 (04) : 609 - 647
  • [22] First report of a new exoskeleton in incomplete spinal cord injury: FreeGait®
    Sipal, Meric Selim
    Yasar, Evren
    Ozisler, Zuhal
    Adiguzel, Emre
    Yildirim, Sinem
    Deler, Omur
    Kirdis, Selin
    Celik, Halil Ibrahim
    Ulusahin, Seda Bicici
    Kayalar, Guelseren
    Karaduman, Aynur Ayse
    JOURNAL OF SPINAL CORD MEDICINE, 2024,
  • [23] Wearable robotic exoskeleton for gait reconstruction in patients with spinal cord injury: A literature review
    Tan, Koki
    Koyama, Soichiro
    Sakurai, Hiroaki
    Teranishi, Toshio
    Kanada, Yoshikiyo
    Tanabe, Shigeo
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2021, 28 : 55 - 64
  • [24] Volitional control of single cortical neurons in a brain-machine interface
    Moritz, Chet T.
    Fetz, Eberhard E.
    JOURNAL OF NEURAL ENGINEERING, 2011, 8 (02)
  • [25] Effects of lower limb exoskeleton gait orthosis compared to mechanical gait orthosis on rehabilitation of patients with spinal cord injury: A systematic review and future perspectives
    Zhang, Chaoyang
    Li, Ning
    Xue, Xiali
    Lu, Xia
    Li, Danjie
    Hong, Qiaomei
    GAIT & POSTURE, 2023, 102 : 64 - 71
  • [26] Practical Brain-Machine Interface System
    Yeom, Hong Gi
    Kim, June Sie
    Chung, Chun Kee
    2017 5TH INTERNATIONAL WINTER CONFERENCE ON BRAIN-COMPUTER INTERFACE (BCI), 2017, : 42 - 43
  • [27] An integrated gait rehabilitation training based on Functional Electrical Stimulation cycling and overground robotic exoskeleton in complete spinal cord injury patients: preliminary results
    Mazzoleni, S.
    Battini, E.
    Rustici, A.
    Stampacchia, G.
    2017 INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS (ICORR), 2017, : 289 - 293
  • [28] Various surfaces challenge gait characteristics of ambulatory patients with spinal cord injury
    Promkeaw, Donlaya
    Arrayawichanon, Preeda
    Thaweewannakij, Thiwabhorn
    Mato, Lugkana
    Amatachaya, Pipatana
    Amatachaya, Sugalya
    SPINAL CORD, 2019, 57 (09) : 805 - 813
  • [29] Is walking symmetry important for ambulatory patients with spinal cord injury?
    Kumprou, Makamas
    Amatachaya, Pipatana
    Sooknuan, Thanat
    Thaweewannakij, Thiwabhorn
    Amatachaya, Sugalya
    DISABILITY AND REHABILITATION, 2018, 40 (07) : 836 - 841
  • [30] MATCHING BRAIN-MACHINE INTERFACE PERFORMANCE, TO SPACE APPLICATIONS
    Citi, Luca
    Tonet, Oliver
    Marinelli, Martina
    BRAIN MACHINE INTERFACES FOR SPACE APPLICATIONS: ENHANCING ASTRONAUT CAPABILITIES, 2009, 86 : 199 - 212