Indicator and calibration material for micro calcifications in dual-energy mammography

被引:0
作者
Chen, Xi [1 ]
Men, Xuanqin [1 ]
Zhang, Lei [2 ]
机构
[1] Xi An Jiao Tong Univ, Inst Image Proc & Pattern Recognit, Xian 710049, Shaanxi, Peoples R China
[2] Hong Kong Polytech Univ, Dept Comp, Kowloon, Peoples R China
来源
MEDICAL BIOMETRICS, PROCEEDINGS | 2007年 / 4901卷
关键词
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Dual-energy mammography can suppress the contrast between adipose and glandular tissues and improve the detectability of microcalcifications (MCs). In the published papers, MCs were calibrated by aluminum and identified by their thickness. However, the variety of compositions of MCs causes the variety of attenuation differences between MCs and MC calibration material which bring about huge calculation errors. In our study, we selected calcium carbonate and calcium phosphate as the most suitable MC calibration materials and the correction coefficient was reasonably determined. Area density was used as MC indicator instead of thickness. Therefore, the calculation errors from MC calibration materials can be reduced a lot and the determination of MCs will become possible.
引用
收藏
页码:265 / +
页数:2
相关论文
共 50 条
[21]   Application of dual-energy techniques to digital mammography [J].
Taibi, A ;
Fabbri, S ;
Baldelli, P ;
di Maggio, C ;
Gennaro, G ;
Marziani, M ;
Tuffanelli, A ;
Gambaccini, M .
DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, :566-568
[22]   A study on dual-energy subtraction in digital mammography (WIP) [J].
Ramirez, V ;
Brandan, ME ;
Ruiz-Trejo, C ;
Márquez-Flores, JA ;
Villaseñor, Y .
MEDICAL PHYSICS, 2003, 30 (06) :1459-1459
[23]   DUAL-ENERGY DIGITAL MAMMOGRAPHY WITH CHEMICAL-SENSITIVITY [J].
RUIZ, JF ;
KURTZ, RL .
RADIOLOGY, 1995, 197 :291-291
[24]   Algorithmic scatter correction in dual-energy digital mammography [J].
Chen, Xi ;
Nishikawa, Robert M. ;
Chan, Suk-tak ;
Lau, Beverly A. ;
Zhang, Lei ;
Mou, Xuanqin .
MEDICAL PHYSICS, 2013, 40 (11)
[25]   Classification of breast microcalcifications using dual-energy mammography [J].
Ghammraoui, Bahaa ;
Makeev, Andrey ;
Zidan, Ahmed ;
Alayoubi, Alaadin ;
Glick, Stephen J. .
JOURNAL OF MEDICAL IMAGING, 2019, 6 (01)
[26]   Classification of breast microcalcifications using dual-energy mammography [J].
Ghammraoui, B. ;
Makeev, A. ;
Glick, S. J. .
MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
[27]   Dual-Energy CT-Based Material Decomposition for Stoichiometric Calibration of DCE CT [J].
Coolens, C. ;
Landry, G. ;
Varon, C. ;
Verhaegen, F. .
MEDICAL PHYSICS, 2013, 40 (06)
[28]   The Experimental Study on Geometric Calibration and Material Discrimination for In Vivo Dual-Energy CT Imaging [J].
Deng, Gang ;
Chen, Mianyi ;
He, Peng ;
Wang, Xing ;
Wu, Xiaochuan ;
Guo, Xiaodong ;
Li, Pengcheng ;
Wei, Biao ;
An, Kang ;
Zheng, Xiaolin ;
Feng, Peng .
BIOMED RESEARCH INTERNATIONAL, 2019, 2019
[29]   Dual-energy digital mammography: Calibration and mapping methods to estimate breast thickness, tissue composition, and/or calcification thickness [J].
Kappadath, S ;
Shaw, C .
MEDICAL PHYSICS, 2002, 29 (06) :1306-1307
[30]   Conventional mammographic image generation in dual-energy digital mammography [J].
Chen, Xi ;
Nishikawa, Robert M. ;
Mou, Xuanqin .
MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668