Design and Fabrication of Quartz Micro-Electro-Mechanical System-Based Double-Ended Tuning Fork with Variable Sections

被引:7
作者
Liang, Jinxing [1 ]
Li, Xuefeng [2 ]
Li, Hongsheng [1 ]
Ni, Yunfang [1 ]
Li, Kunyu [1 ]
Huang, Libin [1 ]
Ueda, Toshitsugu [2 ]
机构
[1] Southeast Univ, Sch Instrument Sci & Engn, Minist Educ, Key Lab Microinertial Instrument & Adv Nav Techno, Nanjing 210096, Peoples R China
[2] Waseda Univ, Grad Sch Informat Prod & Syst, Kitakyushu, Fukuoka 8080135, Japan
关键词
RESONATOR; SENSITIVITY;
D O I
10.1143/JJAP.50.06GM06
中图分类号
O59 [应用物理学];
学科分类号
摘要
In this paper, we report a novel double-ended tuning fork (DETF) with variable sections. The DETF is fabricated using a quartz micro-electromechanical system (MEMS) technique and packaged using the flip chip technique. The central part of the vibration beam is thinned to enhance the force-frequency sensitivity but not decrease the vibration frequency. The mechanical quality factor (Q value) can also be maintained, which determines the mechanical noise performance. Three types of DETF are designed and fabricated with a fixed beam length of 4 mm. The vibration characteristics (vibration frequency, Q value, and equivalent circuit parameters) are evaluated using an impedance analyzer 4294A. The finite element method (FEM) is used to simulate the natural frequency and force-frequency sensitivity. For the natural frequencies, the experimental results agreed well with the simulation results. High Q values are achieved for all the DETFs, which are 9924, 7083, and 6335. By multiplying the force-frequency sensitivity (Delta F) by the measured Q values, the performance of the new DETF structure can be improved by 1.9 times. (c) 2011 The Japan Society of Applied Physics
引用
收藏
页数:4
相关论文
共 25 条
[1]   A Study on Increasing Sensitivity of Rectangular Microcantilevers Used in Biosensors [J].
Ansari, Mohd. Zahid ;
Cho, Chongdu .
SENSORS, 2008, 8 (11) :7530-7544
[2]   New force sensor based on a double ended tuning fork [J].
Barthod, C ;
Gehin, C .
PROCEEDINGS OF THE 2000 IEEE/EIA INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM & EXHIBITION, 2000, :74-78
[3]   Design and performance characteristics of an integrated high-capacity DETF-based force sensor [J].
Cheshmehdoost, A ;
Jones, BE .
SENSORS AND ACTUATORS A-PHYSICAL, 1996, 52 (1-3) :99-102
[4]   CHARACTERISTICS OF A FORCE TRANSDUCER INCORPORATING A MECHANICAL DETF RESONATOR [J].
CHESHMEHDOOST, A ;
JONES, BE ;
OCONNOR, B .
SENSORS AND ACTUATORS A-PHYSICAL, 1991, 26 (1-3) :307-312
[5]   MINIATURE CRYSTALLINE QUARTZ ELECTROMECHANICAL STRUCTURES [J].
CLAYTON, LD ;
EERNISSE, EP ;
WARD, RW ;
WIGGINS, RB .
SENSORS AND ACTUATORS, 1989, 20 (1-2) :171-177
[6]   SURVEY OF QUARTZ BULK RESONATOR SENSOR TECHNOLOGIES [J].
EERNISSE, EP ;
WARD, RW ;
WIGGINS, RB .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1988, 35 (03) :323-330
[7]   Improved cantilever profiles for sensor elements [J].
Fernando, Sanchitha ;
Austin, Michael ;
Chaffey, Jason .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2007, 40 (24) :7652-7655
[8]   Monolithically fabricated double-ended tuning-fork-based force sensor [J].
Fukuzawa, K ;
Ando, T ;
Shibamoto, M ;
Mitsuya, Y ;
Zhang, HD .
JOURNAL OF APPLIED PHYSICS, 2006, 99 (09)
[9]   Simultaneously Measuring Lateral and Vertical Forces with Accurate Gap Control for Clarifying Lubrication Phenomena at Nanometer Gap [J].
Fukuzawa, Kenji ;
Hayakawa, Kosei ;
Matsumura, Noriki ;
Itoh, Shintaro ;
Zhang, Hedong .
TRIBOLOGY LETTERS, 2010, 37 (03) :497-505
[10]   Development of Self-vibration/detection AFM Probe Using Quartz Tuning fork [J].
Hida, Hirotaka ;
Shikida, Mitsuhiro ;
Fukuzawa, Kenji ;
Murakami, Shirou ;
Sato, Kenji ;
Asaumi, Kazuo ;
Iriye, Yasuroh ;
Sato, Kazuo .
IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2009, 4 (03) :378-385