Chromium(III) Potentiometric Sensor Based on Para-Tertiary-Butyl Calix[4]arene

被引:3
|
作者
Sadeghi, Hayedeh Bagheri [1 ]
Tamaddon, Atefeh [1 ]
Afifinia, Hadi [1 ]
Almasian, Nasim [1 ]
Bozorgvar, Fatemeh [1 ]
Mollaei, Somayeh [1 ]
机构
[1] Islamic Azad Univ, Dept Chem, Tehran Cent Branch, Tehran, Iran
关键词
p-tert-butyl calix[4]arene; Chromium(III); Ion selective electrodes; ION-SELECTIVE ELECTRODES; WATER; PRECONCENTRATION; SPECIATION; CR(III); CR(VI);
D O I
10.1002/elan.201100220
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new chromium(III) PVC membrane sensor incorporating p-tertiary-butyl calix[4]arene as ionophore, potassium tetrakis as additive and dibutyl phthalate (DBP) as plasticizer was constructed. The electrode exhibited an excellent potentiometric response over a wide concentration range of 1.0x10(-7)-1.0x10(-1) M with a Nernstian slope of 20 +/- 0.5 mV per decade. The detection limit was 5.0x10(-8) M. The electrode showed a better performance over a pH range of 3.0-8.0, and had a short response time of about <15 s. The electrode was successfully applied to potentiometric titration of Cr (III) with EDTA and for direct determination of chromium(III) in waste water.
引用
收藏
页码:2472 / 2478
页数:7
相关论文
共 50 条
  • [1] URANYL MICROSENSOR: AN ASYMMETRIC POTENTIOMETRIC MEMBRANE SENSOR BASED ON A NEW CALIX[4]ARENE
    Ganjali, Mohammad Reza
    Memari, Zahra
    Norouzi, Parviz
    Shaabani, Behrouz
    Emamalizadeh, Mehdi
    Hanifehpour, Younes
    Faridbod, Farnoush
    ANALYTICAL LETTERS, 2010, 43 (14) : 2220 - 2233
  • [2] Cadmium (II) ion sensing through p-tert-butyl calix[6]arene based potentiometric sensor
    Gupta, Vinod Kumar
    Kumar, S.
    Singh, R.
    Singh, L. P.
    Shoora, S. K.
    Sethi, B.
    JOURNAL OF MOLECULAR LIQUIDS, 2014, 195 : 65 - 68
  • [3] Allergic Contact Dermatitis against para-tertiary-Butyl Catechol in a Room Carer
    Lotz, C.
    Munzer, A.
    Berndt, K.
    Abraham, S.
    Ragaller, Spornraft P.
    Beissert, S.
    Bauer, A.
    JOURNAL DER DEUTSCHEN DERMATOLOGISCHEN GESELLSCHAFT, 2017, 15 : 95 - 95
  • [4] Azo calix[4]arene based neodymium(III)-selective PVC membrane sensor
    Menon, Shobhana K.
    Modi, Nishith R.
    Patel, Bhargav
    Patel, Manishkumar B.
    TALANTA, 2011, 83 (05) : 1329 - 1334
  • [5] Silver(I)-selective PVC membrane potentiometric sensor based on a recently synthesized calix[4]arene
    Demirel, Ayca
    Dogan, Alev
    Akkus, Gulderen
    Yilmaz, Mustafa
    Kilic, Esma
    ELECTROANALYSIS, 2006, 18 (10) : 1019 - 1027
  • [6] New structural motifs in chromium(III) calix[4 and 6]arene chemistry
    Redshaw, Carl
    Homden, Damien
    Hughes, David L.
    Wright, Joseph A.
    Elsegood, Mark R. J.
    DALTON TRANSACTIONS, 2009, (07) : 1231 - 1242
  • [7] A novel cobalt(II)-selective potentiometric sensor based on p-(4-n-butylphenylazo)calix[4]arene
    Kumar, Pankaj
    Shim, Yoon-Bo
    TALANTA, 2009, 77 (03) : 1057 - 1062
  • [8] COORDINATION CHEMISTRY OF THE CALIXARENES .2. EUROPIUM(III) AND PARA-TERT-BUTYL CALIX[6]ARENE
    ENGELHARDT, LM
    FURPHY, BM
    HARROWFIELD, JM
    KEPERT, DL
    WHITE, AH
    WILNER, FR
    AUSTRALIAN JOURNAL OF CHEMISTRY, 1988, 41 (09) : 1465 - 1476
  • [9] Silver(I)-selective membrane potentiometric sensor based on two recently synthesized ionophores containing calix[4]arene
    Aghaie, M.
    Giahi, M.
    Aghaie, H.
    Atryan, A.
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2009, 45 (07) : 804 - 809
  • [10] A new silver(I) potentiometric sensor based on a calix[4]arene substituted at the narrow rim by amide/phosphoryl groups
    Parsa, Majid
    Yaftian, Mohammad Reza
    Matt, Dominique