Development and optimization of ultra-high performance supercritical fluid chromatography mass spectrometry method for high-throughput determination of tocopherols and tocotrienols in human serum

被引:22
|
作者
Pilarova, Veronika [1 ]
Gottvald, Tomas [1 ]
Svoboda, Pavel [1 ]
Novak, Ondrej [2 ,3 ]
Benesova, Karolina [4 ]
Belakova, Sylvie [4 ]
Novakova, Lucie [1 ]
机构
[1] Charles Univ Prague, Fac Pharm, Dept Analyt Chem, Heyrovskeho 1203, Hradec Kralove 50005, Czech Republic
[2] Palacky Univ, Inst Expt Bot CAS, Ctr Reg Hana Biotechnol & Agr Res, Lab Growth Regulators, Slechtitelu 27, Olomouc 78371, Czech Republic
[3] Palacky Univ, Fac Sci, Slechtitelu 27, Olomouc 78371, Czech Republic
[4] Malting Inst Brno, Res Inst Brewing & Malting, Mostecka 7, Brno 61400, Czech Republic
关键词
Ultra-high performance supercritical fluid chromatography; Mass spectrometry; Liquid liquid extraction; Tocopherols; Tocotrienols; Human serum; FAT-SOLUBLE VITAMINS; LIQUID-LIQUID MICROEXTRACTION; ALPHA-TOCOPHEROL; SOYBEAN OIL; PHASE; QUANTIFICATION; FLUORESCENCE; ANTIOXIDANT; EXTRACTION; VEGETABLES;
D O I
10.1016/j.aca.2016.06.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The goal of this study was to develop an effective supercritical fluid chromatography method using single quadrupole MS for analysis of all isomeric forms of vitamin E. Finally, two fast and effective methods, the high resolution one and the high speed one, for the determination of 8 vitamin E isomers in human serum were developed. Rapid high-throughput liquid-liquid extraction was selected as a sample preparation step. Sample pretreatment of 100 mu L human serum was consisted of protein precipitation with 200 mL ethanol and liquid-liquid extraction by 400 mu L hexane/dichloromethane (80/20, v/v). The separation was performed on BEH 2-EP (3.0 x 100 mu m, 1.7 mu m) stationary phase, using isocratic elution with carbon dioxide and 10 mu M ammonium formate in methanol in the ratio 98: 2 for high resolution method with run time 4.5 min and in the ratio 95: 5 for high speed method, where the run time was 2.5 min. The method development included optimization of key parameters: the choice of the suitable stationary phase and the composition of mobile phase, where an influence of various modifiers, their ratio and additives were tested, and optimization of fine tunning parameters including BPR pressure, flow-rate and column temperature. Quantification of all isomeric forms was performed using SIM (single ion monitoring) experiments in ESI positive ion mode. Both high speed and high resolution chromatographic methods were validated in terms of precision, accuracy, range, linearity, LOD, LOQ and matrix effects using the same LLE procedure. The high resolution method provided more sensitive results (LOD: 0.017-0.083 mu g mL(-1)) and better linearity (r(2) > 0.9930) than the high speed one (LOD: 0.083-0.25 mg mL(-1), r(2) > 0.9877) at the cost of double time of analysis. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:252 / 265
页数:14
相关论文
共 50 条
  • [41] High-throughput determination of pesticide residues in food commodities by use of ultra-performance liquid chromatography-tandem mass spectrometry
    Garrido Frenich, A.
    Martinez Vidal, J. L.
    Pastor-Montoro, E.
    Romero-Gonzalez, R.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (03) : 947 - 959
  • [42] High throughput identification and quantification of 16 antipsychotics and 8 major metabolites in serum using ultra-high performance liquid chromatography-tandem mass spectrometry
    Patteet, Lisbeth
    Maudens, Kristof E.
    Sabbe, Bernard
    Morrens, Manuel
    De Doncker, Mireille
    Neels, Hugo
    CLINICA CHIMICA ACTA, 2014, 429 : 51 - 58
  • [43] Determination of 16 polycyclic aromatic hydrocarbons in tire rubber by ultra-high performance supercritical fluid chromatography combined with atmospheric pressure photoionization-tandem mass spectrometry
    Tang, Yan
    Sun, Shuqi
    Zhang, Linyu
    Du, Zhenxia
    Zhuang, Jingcong
    Pan, Jinheng
    ANALYTICAL METHODS, 2018, 10 (40) : 4902 - 4908
  • [44] Determination of eight polyphenols and pantothenic acid in extra-virgin olive oil samples by a simple, fast, high-throughput and sensitive ultra high performance liquid chromatography with tandem mass spectrometry method
    Gosetti, Fabio
    Bolfi, Bianca
    Manfredi, Marcello
    Calabrese, Giorgio
    Marengo, Emilio
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (18) : 3130 - 3136
  • [45] Development of a Sensitive and High-Throughput Assay for Simultaneous Quantification of 5 Tyrosine Kinase Inhibitors and 2 Active Metabolites in Human Plasma Using Ultra-high Performance Liquid Chromatography Coupled to Tandem Mass Spectrometry
    Sumimoto, Takahiro
    Nakahara, Ryosuke
    Suzuki, Yosuke
    Tanaka, Ryota
    Yoshida, Natsumi
    Ogata, Masao
    Itoh, Hiroki
    THERAPEUTIC DRUG MONITORING, 2022, 44 (03) : 419 - 429
  • [46] Ultra-sensitive determination of formoterol in human serum by high performance liquid chromatography and electrospray tandem mass spectrometry
    Mascher, DG
    Zech, K
    Nave, R
    Kubesch, KM
    Mascher, HJ
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 830 (01): : 25 - 34
  • [47] A rapid method for the determination of mycotoxins in edible vegetable oils by ultra-high performance liquid chromatography-tandem mass spectrometry
    Hidalgo-Ruiz, Jose L.
    Romero-Gonzalez, Roberto
    Martinez Vidal, Jose Luis
    Garrido Frenich, Antonia
    FOOD CHEMISTRY, 2019, 288 (22-28) : 22 - 28
  • [48] Modified QuEChERS method combined with ultra-high performance liquid chromatography tandem mass spectrometry for the simultaneous determination of 26 mycotoxins in sesame butter
    Liu, Ying
    Han, Shen
    Lu, Meiling
    Wang, Peiyue
    Han, Jing
    Wang, Jinhua
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 970 : 68 - 76
  • [49] A green and rapid analytical method for determination of kitasamycin in animal feedstuffs by ultra-high performance liquid chromatography tandem mass spectrometry
    Xu, Feng
    Yu, Jiayong
    Zhang, Rongrong
    Zhang, Zeming
    Sun, Aili
    Shi, Xizhi
    Wu, Yinliang
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1676
  • [50] A high-throughput liquid chromatography-tandem mass spectrometry method for simultaneous determination of direct oral anticoagulants in human plasma
    Zidekova, Nela
    Prso, Kristian
    Brisudova, Kristina
    Babalova, Lucia
    Bolek, Tomas
    Sivak, Stefan
    Kurca, Egon
    Mokry, Juraj
    Samos, Matej
    Nosal, Vladimir
    Kertys, Martin
    JOURNAL OF SEPARATION SCIENCE, 2023, 46 (13)