Development and optimization of ultra-high performance supercritical fluid chromatography mass spectrometry method for high-throughput determination of tocopherols and tocotrienols in human serum

被引:22
|
作者
Pilarova, Veronika [1 ]
Gottvald, Tomas [1 ]
Svoboda, Pavel [1 ]
Novak, Ondrej [2 ,3 ]
Benesova, Karolina [4 ]
Belakova, Sylvie [4 ]
Novakova, Lucie [1 ]
机构
[1] Charles Univ Prague, Fac Pharm, Dept Analyt Chem, Heyrovskeho 1203, Hradec Kralove 50005, Czech Republic
[2] Palacky Univ, Inst Expt Bot CAS, Ctr Reg Hana Biotechnol & Agr Res, Lab Growth Regulators, Slechtitelu 27, Olomouc 78371, Czech Republic
[3] Palacky Univ, Fac Sci, Slechtitelu 27, Olomouc 78371, Czech Republic
[4] Malting Inst Brno, Res Inst Brewing & Malting, Mostecka 7, Brno 61400, Czech Republic
关键词
Ultra-high performance supercritical fluid chromatography; Mass spectrometry; Liquid liquid extraction; Tocopherols; Tocotrienols; Human serum; FAT-SOLUBLE VITAMINS; LIQUID-LIQUID MICROEXTRACTION; ALPHA-TOCOPHEROL; SOYBEAN OIL; PHASE; QUANTIFICATION; FLUORESCENCE; ANTIOXIDANT; EXTRACTION; VEGETABLES;
D O I
10.1016/j.aca.2016.06.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The goal of this study was to develop an effective supercritical fluid chromatography method using single quadrupole MS for analysis of all isomeric forms of vitamin E. Finally, two fast and effective methods, the high resolution one and the high speed one, for the determination of 8 vitamin E isomers in human serum were developed. Rapid high-throughput liquid-liquid extraction was selected as a sample preparation step. Sample pretreatment of 100 mu L human serum was consisted of protein precipitation with 200 mL ethanol and liquid-liquid extraction by 400 mu L hexane/dichloromethane (80/20, v/v). The separation was performed on BEH 2-EP (3.0 x 100 mu m, 1.7 mu m) stationary phase, using isocratic elution with carbon dioxide and 10 mu M ammonium formate in methanol in the ratio 98: 2 for high resolution method with run time 4.5 min and in the ratio 95: 5 for high speed method, where the run time was 2.5 min. The method development included optimization of key parameters: the choice of the suitable stationary phase and the composition of mobile phase, where an influence of various modifiers, their ratio and additives were tested, and optimization of fine tunning parameters including BPR pressure, flow-rate and column temperature. Quantification of all isomeric forms was performed using SIM (single ion monitoring) experiments in ESI positive ion mode. Both high speed and high resolution chromatographic methods were validated in terms of precision, accuracy, range, linearity, LOD, LOQ and matrix effects using the same LLE procedure. The high resolution method provided more sensitive results (LOD: 0.017-0.083 mu g mL(-1)) and better linearity (r(2) > 0.9930) than the high speed one (LOD: 0.083-0.25 mg mL(-1), r(2) > 0.9877) at the cost of double time of analysis. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:252 / 265
页数:14
相关论文
共 50 条
  • [31] High-throughput method for the determination of nitroimidazoles in muscle samples by liquid chromatography coupled to mass spectrometry
    A. Rúbies
    G. Sans
    P. Kumar
    M. Granados
    R. Companyó
    F. Centrich
    Analytical and Bioanalytical Chemistry, 2015, 407 : 4411 - 4421
  • [32] Determination of sulforaphane in 32 vegetables by ultra-high performance liquid chromatography tandem mass spectrometry
    Chen, Miao
    Pu, Jie
    Xiang, Wei
    Zhao, Xuewen
    Zeng, Jing
    Chinese Journal of Analysis Laboratory, 2021, 40 (01) : 21 - 24
  • [33] High-throughput determination of pesticide residues in food commodities by use of ultra-performance liquid chromatography–tandem mass spectrometry
    A. Garrido Frenich
    J. L. Martínez Vidal
    E. Pastor-Montoro
    R. Romero-González
    Analytical and Bioanalytical Chemistry, 2008, 390 : 947 - 959
  • [34] A simple, accurate, time-saving and green method for the determination of 15 sulfonamides and metabolites in serum samples by ultra-high performance supercritical fluid chromatography
    Zhang Yuan
    Zhou Wei-E
    Li Shao-Hui
    Ren Zhi-Qin
    Li Wei-Qing
    Zhou Yu
    Feng Xue-Song
    Wu Wen-Jie
    Zhang Feng
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1432 : 132 - 139
  • [35] High-Throughput Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry Method Validation for the Estimation of Atorvastatin and Active Metabolites in Human Plasma
    Agrawal, Nikhil
    Mittal, Amit
    ASSAY AND DRUG DEVELOPMENT TECHNOLOGIES, 2023, 21 (03) : 110 - 125
  • [36] Determination of cannabinoid and synthetic cannabinoid metabolites in wastewater by liquid-liquid extraction and ultra-high performance supercritical fluid chromatography-tandem mass spectrometry
    Gonzalez-Marino, Iria
    Thomas, Kevin V.
    Reid, Malcolm J.
    DRUG TESTING AND ANALYSIS, 2018, 10 (01) : 222 - 228
  • [37] The Benefits of Ultra-High-Performance Supercritical Fluid Chromatography in Determination of Lipophilic Vitamins in Dietary Supplements
    Novakova, Lucie
    Sejkorova, Magdalena
    Smolkova, Katerina
    Plachka, Katerina
    Svec, Frantisek
    CHROMATOGRAPHIA, 2019, 82 (01) : 477 - 487
  • [38] Development of ultra-high-performance supercritical fluid chromatography-mass spectrometry assays to analyze potential biomarkers in sweat
    Herniman, Julie M.
    Worsley, Peter R.
    Greenhill, Rachel
    Bader, Dan L.
    Langley, G. John
    JOURNAL OF SEPARATION SCIENCE, 2022, 45 (02) : 542 - 550
  • [39] Development of an ultra-high-performance liquid chromatography-tandem mass spectrometry method for high throughput determination of organophosphorus flame retardants in environmental water
    Wang, Xiao-wei
    Liu, Jing-fu
    Yin, Yong-guang
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (38) : 6705 - 6711
  • [40] High-throughput phospholipid profiling system based on supercritical fluid extraction-supercritical fluid chromatography/mass spectrometry for dried plasma spot analysis
    Uchikata, Takato
    Matsubara, Atsuki
    Fukusaki, Eiichiro
    Bamba, Takeshi
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1250 : 69 - 75