Development and optimization of ultra-high performance supercritical fluid chromatography mass spectrometry method for high-throughput determination of tocopherols and tocotrienols in human serum

被引:22
|
作者
Pilarova, Veronika [1 ]
Gottvald, Tomas [1 ]
Svoboda, Pavel [1 ]
Novak, Ondrej [2 ,3 ]
Benesova, Karolina [4 ]
Belakova, Sylvie [4 ]
Novakova, Lucie [1 ]
机构
[1] Charles Univ Prague, Fac Pharm, Dept Analyt Chem, Heyrovskeho 1203, Hradec Kralove 50005, Czech Republic
[2] Palacky Univ, Inst Expt Bot CAS, Ctr Reg Hana Biotechnol & Agr Res, Lab Growth Regulators, Slechtitelu 27, Olomouc 78371, Czech Republic
[3] Palacky Univ, Fac Sci, Slechtitelu 27, Olomouc 78371, Czech Republic
[4] Malting Inst Brno, Res Inst Brewing & Malting, Mostecka 7, Brno 61400, Czech Republic
关键词
Ultra-high performance supercritical fluid chromatography; Mass spectrometry; Liquid liquid extraction; Tocopherols; Tocotrienols; Human serum; FAT-SOLUBLE VITAMINS; LIQUID-LIQUID MICROEXTRACTION; ALPHA-TOCOPHEROL; SOYBEAN OIL; PHASE; QUANTIFICATION; FLUORESCENCE; ANTIOXIDANT; EXTRACTION; VEGETABLES;
D O I
10.1016/j.aca.2016.06.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The goal of this study was to develop an effective supercritical fluid chromatography method using single quadrupole MS for analysis of all isomeric forms of vitamin E. Finally, two fast and effective methods, the high resolution one and the high speed one, for the determination of 8 vitamin E isomers in human serum were developed. Rapid high-throughput liquid-liquid extraction was selected as a sample preparation step. Sample pretreatment of 100 mu L human serum was consisted of protein precipitation with 200 mL ethanol and liquid-liquid extraction by 400 mu L hexane/dichloromethane (80/20, v/v). The separation was performed on BEH 2-EP (3.0 x 100 mu m, 1.7 mu m) stationary phase, using isocratic elution with carbon dioxide and 10 mu M ammonium formate in methanol in the ratio 98: 2 for high resolution method with run time 4.5 min and in the ratio 95: 5 for high speed method, where the run time was 2.5 min. The method development included optimization of key parameters: the choice of the suitable stationary phase and the composition of mobile phase, where an influence of various modifiers, their ratio and additives were tested, and optimization of fine tunning parameters including BPR pressure, flow-rate and column temperature. Quantification of all isomeric forms was performed using SIM (single ion monitoring) experiments in ESI positive ion mode. Both high speed and high resolution chromatographic methods were validated in terms of precision, accuracy, range, linearity, LOD, LOQ and matrix effects using the same LLE procedure. The high resolution method provided more sensitive results (LOD: 0.017-0.083 mu g mL(-1)) and better linearity (r(2) > 0.9930) than the high speed one (LOD: 0.083-0.25 mg mL(-1), r(2) > 0.9877) at the cost of double time of analysis. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:252 / 265
页数:14
相关论文
共 50 条
  • [21] Determination of amphetamine enantiomers in urine by conductive vial electromembrane extraction and ultra-high performance supercritical fluid chromatography tandem mass spectrometry
    Skaalvik, Tonje Gottenberg
    Oiestad, Elisabeth Leere
    Pedersen-Bjergaard, Stig
    Hegstad, Solfrid
    DRUG TESTING AND ANALYSIS, 2023, 15 (08) : 909 - 918
  • [22] High-Throughput Simultaneous Analysis of Pesticides by Supercritical Fluid Chromatography Coupled with High-Resolution Mass Spectrometry
    Ishibashi, Megumi
    Izumi, Yoshihiro
    Sakai, Miho
    Ando, Takashi
    Fukusaki, Eiichiro
    Bamba, Takeshi
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2015, 63 (18) : 4457 - 4463
  • [23] Development of an untargeted DNA adductomics method by ultra-high performance liquid chromatography coupled to high-resolution mass spectrometry
    La Barbera, Giorgia
    Shuler, Marshal Spenser
    Beck, Soren Hammershoj
    Ibsen, Per Holger
    Lindberg, Lars Joachim
    Karstensen, John Gasdal
    Dragsted, Lars Ove
    TALANTA, 2025, 282
  • [24] Determination of Five Retinol Isomers in Animal Livers Using Ultra-High Performance Supercritical Fluid Chromatography
    Zhao, Haiyan
    Li, Bing
    Zhao, Rong
    Tu, Ruiying
    CHROMATOGRAPHIA, 2018, 81 (08) : 1173 - 1180
  • [25] Ultra-high performance supercritical fluid chromatography in impurity control II: Method validation
    Plachka, Katerina
    Khalikova, Maria
    Babicova, Barbora
    Nemcova, Zdenka
    Roubickova, Lucie
    Svec, Frantisek
    Novakova, Lucie
    ANALYTICA CHIMICA ACTA, 2020, 1117 : 48 - 59
  • [26] A sensitive, high-throughput, and ecofriendly method for the determination of lumefantrine, artemether, and its active metabolite dihydroartemisinin by supercritical fluid chromatography and tandem mass spectrometry
    Yang, Yinxian
    Gao, Hailing
    Hou, Shanshan
    Sue, Ruijuan
    Liu, Hongzhuo
    Sun, Jin
    JOURNAL OF SEPARATION SCIENCE, 2018, 41 (12) : 2688 - 2696
  • [27] Determination of vitamins A, D and E in a small volume of human plasma by a high-throughput method based on liquid chromatography/tandem mass spectrometry
    Midttun, Oivind
    Ueland, Per M.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (14) : 1942 - 1948
  • [28] Ultra-high performance supercritical fluid chromatography-mass spectrometry procedure for analysis of monosaccharides from plant gum binders
    Pauk, Volodymyr
    Pluhacek, Tomas
    Havlicek, Vladimir
    Lemr, Karel
    ANALYTICA CHIMICA ACTA, 2017, 989 : 112 - 120
  • [29] Simultaneous determination of parabens, bisphenols and alkylphenols in human placenta by ultra-high performance liquid chromatography-tandem mass spectrometry
    Van Overmeire, Ilse
    Vrijens, Karen
    Nawrot, Tim
    Van Nieuwenhuyse, An
    Van Loco, Joris
    Reyns, Tim
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1121 : 96 - 102
  • [30] High-throughput method for the determination of nitroimidazoles in muscle samples by liquid chromatography coupled to mass spectrometry
    A. Rúbies
    G. Sans
    P. Kumar
    M. Granados
    R. Companyó
    F. Centrich
    Analytical and Bioanalytical Chemistry, 2015, 407 : 4411 - 4421