Incidence, predictors, in-hospital, and late outcomes of coronary artery perforations

被引:69
作者
Stankovic, G
Orlic, D
Corvaja, N
Airoldi, F
Chieffo, A
Spanos, V
Montorfano, M
Carlino, M
Finci, L
Sangiorgi, G
Colombo, A
机构
[1] Columbus Hosp, Milan, Italy
[2] Hosp San Raffaele, I-20132 Milan, Italy
关键词
D O I
10.1016/j.amjcard.2003.09.042
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We sought to determine the incidence of coronary perforations, predisposing factors, and in-hospital and late outcome of patients with coronary perforations. Perforations occurred in 0.84% of treated lesions and more frequently in patients with complex lesions after atheroablative procedures and who underwent intravascular ultrasound guided lumen optimization. The incidence of adverse events, emergency coronary artery bypass grafting and death significantly decreased over time. ((C) 2004 by Excerpta Medica, Inc.
引用
收藏
页码:213 / 216
页数:4
相关论文
共 12 条
  • [1] PERFORATIONS AFTER PERCUTANEOUS CORONARY INTERVENTIONS - CLINICAL, ANGIOGRAPHIC, AND THERAPEUTIC OBSERVATIONS
    AJLUNI, SC
    GLAZIER, S
    BLANKENSHIP, L
    ONEILL, WW
    SAFIAN, RD
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, 32 (03): : 206 - 212
  • [2] Comparison of immediate and intermediate-term results of intravascular ultrasound versus angiography-guided Palmaz-Schatz stent implantation in matched lesions
    Albiero, R
    Rau, T
    Schluter, M
    DiMario, C
    Reimers, B
    Mathey, DG
    Tobis, JM
    Schofer, J
    Colombo, A
    [J]. CIRCULATION, 1997, 96 (09) : 2997 - 3005
  • [3] Mechanisms of residual lumen stenosis after high-pressure stent implantation -: A quantitative coronary angiography and intravascular ultrasound study
    Bermejo, J
    Botas, J
    García, E
    Elízaga, J
    Osende, J
    Soriano, J
    Abeytua, M
    Delcán, JL
    [J]. CIRCULATION, 1998, 98 (02) : 112 - 118
  • [4] CORONARY-ARTERY PERFORATION DURING EXCIMER LASER CORONARY ANGIOPLASTY
    BITTL, JA
    RYAN, TJ
    KEANEY, JF
    TCHENG, JE
    ELLIS, SG
    ISNER, JM
    SANBORN, TA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (05) : 1158 - 1165
  • [5] CARRO MJ, 1993, COLLECT MATH, V72, P47
  • [6] Cohen BM, 1996, CATHETER CARDIO DIAG, V38, P55
  • [7] Coronary perforation during percutaneous coronary intervention in the era of abciximab platelet glycoprotein IIb/IIIa blockade: An algorithm for percutaneous management
    Dippel, EJ
    Kereiakes, DJ
    Tramuta, DA
    Broderick, TM
    Shimshak, TM
    Roth, EM
    Hattemer, CR
    Runyon, JP
    Whang, DD
    Schneider, JF
    Abbottsmith, CW
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 52 (03) : 279 - 286
  • [8] INCREASED CORONARY PERFORATION IN THE NEW DEVICE ERA - INCIDENCE, CLASSIFICATION, MANAGEMENT, AND OUTCOME
    ELLIS, SG
    AJLUNI, S
    ARNOLD, AZ
    POPMA, JJ
    BITTL, JA
    EIGLER, NL
    COWLEY, MJ
    RAYMOND, RE
    SAFIAN, RD
    WHITLOW, PL
    [J]. CIRCULATION, 1994, 90 (06) : 2725 - 2730
  • [9] Incidence, management, and outcome of coronary artery perforation during percutaneous coronary intervention
    Gruberg, L
    Pinnow, E
    Flood, R
    Bonnet, Y
    Tebeica, M
    Waksman, R
    Satler, LF
    Pichard, AD
    Kent, KM
    Leon, MB
    Lindsay, J
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (06) : 680 - +
  • [10] Coronary artery perforation during percutaneous intervention: incidence and outcome
    Gunning, MG
    Williams, IL
    Jewitt, DE
    Shah, AM
    Wainwright, RJ
    Thomas, MR
    [J]. HEART, 2002, 88 (05) : 495 - 498