An innovative building envelope with variable thermal performance for passive heating systems

被引:27
作者
Si, Pengfei [1 ,3 ]
Lv, Yuexia [2 ,4 ]
Rong, Xiangyang [3 ]
Shi, Lijun [3 ]
Yan, Jinyue [4 ]
Wang, Xin [1 ,5 ]
机构
[1] Tsinghua Univ, Dept Bldg Sci, Beijing, Peoples R China
[2] Qilu Univ Technol, Sch Mech & Automot Engn, Shandong Acad Sci, Jinan, Peoples R China
[3] China Southwest Architecture Design & Res Inst Co, Chengdu, Peoples R China
[4] Malardalen Univ, Sch Business Soc & Energy, Vasteras, Sweden
[5] Beijing Key Lab Indoor Air Qual Evaluat & Control, Beijing, Peoples R China
基金
对外科技合作项目(国际科技项目); 中国国家自然科学基金;
关键词
Passive solar building; Solar heat gain coefficient; Thermal resistance; Renewable energy; Variable thermal performance; TROMBE WALL SYSTEM; OPPORTUNITIES; DESIGN;
D O I
10.1016/j.apenergy.2020.115175
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The integration of passive solar heating strategies into the existing buildings has been considered as an innovative and effective approach to mitigate energy and environmental issues. To balance the trade-off between solar heat gain and thermal insulation in traditional passive solar systems, this paper presented an innovative envelope with variable thermal performance for passive solar buildings. Field measurement was carried out to validate the feasibility of the transparent building envelope under step control operation strategy to building comfortable indoor environment especially in cold plateau areas. The experimental results show that, even under harsh climate conditions, the application of the proposed building envelope effectively increases the heat gain and maintains indoor temperature at a relatively comfortable level in the studied case. The average indoor air temperature of the studied rooms is at 13.0-14.0 degrees C, with the highest temperature up to 21 degrees C. Numerical simulation by DesignBuilder software was further developed to exploit the efficiency of the proposed building envelope under the step control operation strategy for increasing the indoor temperature. The simulation results show the same tendency with the filed measurement results. The operation strategy of opening indoor window at 10:00 am and closing at 5:00 pm can achieve the maximization of solar gain, significantly increasing the indoor temperature. Attributed to good balance between solar heat gain coefficient and thermal resistance, the average temperature of the room with the proposed envelope mode is 2.0 degrees C (sunny day) and 1.5 degrees C (cloudy day) higher than that of another three passive solar envelope operation modes, respectively. In general, the proposed building envelope with variable thermal performance has high potential to improve the indoor thermal environment in cold plateau areas at low cost.
引用
收藏
页数:11
相关论文
共 23 条
  • [11] Design Method of Housing with Direct Solar Heat Gain by Using GIS Data in Cold Regions
    Mori, Taro
    Ogata, Kousuke
    Oosawa, Hisato
    [J]. 6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 2208 - 2213
  • [12] Experiments and simulations on the thermal performance of a sunspace attached to a room including heat-storing porous bed and water tanks
    Owrak, Mehrnaz
    Aminy, Mohammad
    Jamal-Abad, Milad Tajik
    Dehghan, Maziar
    [J]. BUILDING AND ENVIRONMENT, 2015, 92 : 142 - 151
  • [13] Heat transfer analysis of a Trombe wall with a projecting channel design
    Rabani, Mehran
    Kalantar, Vali
    Rabani, Mehrdad
    [J]. ENERGY, 2017, 134 : 943 - 950
  • [14] Experimental study of the heating performance of a Trombe wall with a new design
    Rabani, Mehran
    Kalantar, Vali
    Dehghan, Ali A.
    Faghih, Ahmadreza K.
    [J]. SOLAR ENERGY, 2015, 118 : 359 - 374
  • [15] Trombe walls: A review of opportunities and challenges in research and development
    Saadatian, Omidreza
    Sopian, K.
    Lim, C. H.
    Asim, Nilofar
    Sulaiman, M. Y.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (08) : 6340 - 6351
  • [16] An optimization method applied to active solar energy systems for buildings in cold plateau areas - The case of Lhasa
    Si, Pengfei
    Feng, Ya
    Lv, Yuexia
    Rong, Xiangyang
    Pan, Yungang
    Liu, Xichen
    Yan, Jinyue
    [J]. APPLIED ENERGY, 2017, 194 : 487 - 498
  • [17] Sichuan Province Housing and. Urban and Rural Construction Department, DB5150272019 SICH PR
  • [18] Heating and cooling energy trends and drivers in buildings
    Uerge-Vorsatz, Diana
    Cabeza, Luisa F.
    Serrano, Susana
    Barreneche, Camila
    Petrichenko, Ksenia
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 41 : 85 - 98
  • [19] Experimental monitoring of a sunspace applied to a NZEB mock-up: Assessing and comparing the energy benefits of different configurations
    Ulpiani, Giulia
    Giuliani, Diego
    Romagnoli, Alessandra
    di Perna, Costanzo
    [J]. ENERGY AND BUILDINGS, 2017, 152 : 194 - 215
  • [20] Building envelope with variable thermal performance: Opportunities and challenges
    Wang, Xin
    Sun, Xiaoyu
    Yu, Chuck W. F.
    [J]. INDOOR AND BUILT ENVIRONMENT, 2018, 27 (06) : 729 - 733