Innovations in Quality Improvement of Intravascular Catheter-Related Bloodstream Infections

被引:1
作者
Karnatak, Rajendra [1 ]
Rupp, Mark E. [1 ]
Cawcutt, Kelly [1 ]
机构
[1] Univ Nebraska Med Ctr, Div Infect Dis, 985400 Nebraska Med Ctr, Omaha, NE 68198 USA
关键词
Catheter-related bloodstream infection; Central line-associated bloodstream infection; Central venous catheter; Bacteremia; Healthcare-associated infection; Antimicrobial lock therapy; CENTRAL VENOUS CATHETER; CARE-ASSOCIATED INFECTIONS; ANTIBIOTIC-LOCK THERAPY; DIFFERENTIAL TIME; CHANGING EPIDEMIOLOGY; DIAGNOSIS; CHLORHEXIDINE; CULTURES; PREVENTION; METAANALYSIS;
D O I
10.1007/s40506-019-0180-5
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Purpose of reviewSignificant reductions in catheter-related bloodstream infections (CRBSI) have occurred in the United States. Reductions in CRBSIs are attributed to the widespread implementation of the practice-based measures and innovations in the diagnosis, treatment, and prevention of CRBSI.Recent findingsDiagnosis of CRBSI historically required removal of the central venous catheter (CVC) for catheter tip culture. Removing the CVC for CRBSI diagnosis predisposes many patients to potential life-threatening complications. Advances in diagnostic techniques such as culturing catheter hubs, catheter entry site cultures, applying differential time to positivity, molecular diagnostics, biomarkers, and innovative approaches like biosensors on the CVC lumen may provide an alternative to CVC removal. Removal of the CVC is common for the treatment of CRBSI; however, antimicrobial lock therapy is increasingly used as a CVC salvage method. Implementation of newer technology such as antimicrobial coated catheters, chlorhexidine-impregnated dressings, and antiseptic port protectors are crucial for the prevention of CRBSIs. Increasing evidence also support newer sutureless CVC securement devices prevent CRBSIs.SummaryCRBSI remains a significant clinical problem despite advances made in the diagnosis, management, and prevention. Molecular techniques are increasingly being used for pathogen identification in CRBSI, but the optimal diagnostic test remains debatable. Increasing experience is being gained with antimicrobial lock therapy for CRBSI treatment with catheter salvage. Use and adherence to practice-based measures and technological innovations has significantly reduced CRBSIs. Continued efforts are required to develop a cost-effective and targeted approach for CRBSI prevention.
引用
收藏
页码:23 / 41
页数:19
相关论文
共 108 条
[81]   Watchful waiting versus immediate catheter removal in ICU patients with suspected catheter-related infection: a randomized trial [J].
Rijnders, BJ ;
Peetermans, WE ;
Verwaest, C ;
Wilmer, A ;
Wijngaerden, EV .
INTENSIVE CARE MEDICINE, 2004, 30 (06) :1073-1080
[82]   Comparative Efficacies of Antimicrobial Catheter Lock Solutions for Fungal Biofilm Eradication in an in Vitro Model of Catheter-Related Fungemia [J].
Rosenblatt, Joel ;
Reitzel, Ruth A. ;
Vargas-Cruz, Nylev ;
Chaftari, Anne-Marie ;
Hachem, Ray ;
Raad, Issam I. .
JOURNAL OF FUNGI, 2017, 3 (01)
[83]   Central Line-Associated Bloodstream Infections in Limited-Resource Countries: A Review of the Literature [J].
Rosenthal, Victor D. .
CLINICAL INFECTIOUS DISEASES, 2009, 49 (12) :1899-1907
[84]   Outbreak of bloodstream infection temporally associated with the use of an intravascular needleless valve [J].
Rupp, Mark E. ;
Sholtz, Lee A. ;
Jourdan, Dawn R. ;
Marion, Nedra D. ;
Tyner, Laura K. ;
Fey, Paul D. ;
Iwen, Peter C. ;
Anderson, James R. .
CLINICAL INFECTIOUS DISEASES, 2007, 44 (11) :1408-1414
[85]   Adequate Disinfection of a Split-Septum Needleless Intravascular Connector with a 5-Second Alcohol Scrub [J].
Rupp, Mark E. ;
Yu, Stephanie ;
Huerta, Tomas ;
Cavalieri, R. Jennifer ;
Alter, Roxanne ;
Fey, Paul D. ;
Van Schooneveld, Trevor ;
Anderson, James R. .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2012, 33 (07) :661-665
[86]  
Rupp ME, 2005, ANN INTERN MED, V143, pI36, DOI 10.7326/0003-4819-143-8-200510180-00007
[87]   Meta-analysis: Methods for diagnosing intravascular device-related bloodstream infection [J].
Safdar, N ;
Fine, JP ;
Maki, DG .
ANNALS OF INTERNAL MEDICINE, 2005, 142 (06) :451-466
[88]   Chlorhexidine-Impregnated Dressing for Prevention of Catheter-Related Bloodstream Infection: A Meta-Analysis [J].
Safdar, Nasia ;
O'Horo, John C. ;
Ghufran, Aiman ;
Bearden, Allison ;
Didier, Maria Eugenia ;
Chateau, Dan ;
Maki, Dennis G. .
CRITICAL CARE MEDICINE, 2014, 42 (07) :1703-1713
[89]   Individual versus pooled multiple-lumen blood cultures for the diagnosis of intravascular catheter-related infections [J].
Samara Herrera-Guerra, Alexis ;
Garza-Gonzalez, Elvira ;
Fernando Martinez-Resendez, Michel ;
Martin Llaca-Diaz, Jorge ;
Camacho-Ortiz, Adrian .
AMERICAN JOURNAL OF INFECTION CONTROL, 2015, 43 (07) :715-718
[90]  
Sathiyamurthy Sundar, 2016, World J Clin Pediatr, V5, P159, DOI 10.5409/wjcp.v5.i2.159