Comparison of the MOS capacitor hydrogen sensors with different SiO2 film thicknesses and a Ni-gate film in a 4% hydrogen-nitrogen mixture

被引:19
作者
Aval, L. Fekri [1 ]
Elahi, S. M. [1 ]
Darabi, E. [1 ]
Sebt, S. A. [1 ]
机构
[1] Islamic Azad Univ, Sci & Res Branch, Plasma Phys Res Ctr, Tehran, Iran
关键词
Hydrogen sensor; H-2; -N-2; mixture; Flat band voltage; BTS technique; Response; GAS SENSORS; RELIABILITY; PALLADIUM;
D O I
10.1016/j.snb.2015.04.039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study a MOS capacitive-type hydrogen gas sensor with the Ni/SiO2 /Si structure has been fabricated. The influence of SiO2 film thickness on the sensor response speed, response (R%), and Flat-Band-Voltage (V-FB) has been investigated at 140 degrees C and 100 kHz frequency. Devices were fabricated on (0.22 SZ cm) 400 n-type Si and oxide layer has been characterized using Scanning electron microscopy (SEM) and Atomic force microscopy (AFM). Four sensors are reported at different SiO2 film thickness (28 nm, 40 nm, 46 nm and 53 nm) and results are compared. The VFB for films with 28 nm and 53 nm thicknesses was measured in pure N-2 and 4% H-2-N-2 mixtures. In the former case, results were obtained at 1 V and 2 V and in the later case the VFB shift was 0.3 V and 0.05V. Using MOS C-V measurement under the Bias Thermal Stress (BTS) technique, the trapped charges were measured. Results indicate an increase in trapped charge which is due to an increase in the oxide film thickness. The highest response observed at the bias voltage of (0 V) for a 28 nm SiO2 film thickness is 87.5%. The response decreases with the increase of SiO2 film thickness. The shortest H-2 response/recovery time observed is in the Ni/SiO2/Si sensor with 28 nm SiO2 film thickness. Experimental results demonstrate that the sensor is highly sensitive to SiO2 film thickness, which can be used for response, response/recovery time and VFB studies of MOS capacitive gas sensors and low-cost hydrogen detectors with 4% hydrogen concentration responses. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:367 / 373
页数:7
相关论文
共 32 条
[11]   The influence of the insulator surface properties on the hydrogen response of field-effect gas sensors -: art. no. 034903 [J].
Eriksson, M ;
Salomonsson, A ;
Lundström, I ;
Briand, D ;
Åbom, AE .
JOURNAL OF APPLIED PHYSICS, 2005, 98 (03)
[12]   Low-power gas sensors based on work-function measurement in low-cost hybrid flip-chip technology [J].
Fleischer, M ;
Ostrick, B ;
Pohle, R ;
Simon, E ;
Meixner, H ;
Bilger, C ;
Daeche, F .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 80 (03) :169-173
[13]   THE EFFECT OF HYDROGEN AND CARBON-MONOXIDE ON THE INTERFACE STATE DENSITY IN MOS GAS SENSORS WITH ULTRA-THIN PALLADIUM GATES [J].
FORMOSO, MA ;
MACLAY, GJ .
SENSORS AND ACTUATORS B-CHEMICAL, 1990, 2 (01) :11-22
[14]  
Gray PaulR., 2009, ANAL DESIGN ANALOG I, V5th, P40
[15]  
Haynes W.M., 2008, CRC HDB CHEM PHYS, P12
[16]   Hydrogen sensors - A review [J].
Huebert, T. ;
Boon-Brett, L. ;
Black, G. ;
Banach, U. .
SENSORS AND ACTUATORS B-CHEMICAL, 2011, 157 (02) :329-352
[17]   On the Voltage and Frequency Distribution of Dielectric Properties and ac Electrical Conductivity in Al/SiO2/p-Si (MOS) Capacitors [J].
Kaya, Ahmet ;
Altindal, Semsettin ;
Asar, Yasemin Safak ;
Sonmez, Zekayi .
CHINESE PHYSICS LETTERS, 2013, 30 (01)
[18]   Fabrication and characterization of gridded Pt/SiO2/Si MOS structure for hydrogen and hydrogen sulphide sensing [J].
Kumar, Vinod ;
Sunny ;
Rawal, Ishpal ;
Mishra, V. N. ;
Dwivedi, R. ;
Das, R. R. .
MATERIALS CHEMISTRY AND PHYSICS, 2014, 146 (03) :418-424
[19]   Pd-Ni hydrogen sponge for highly sensitive nanogap-based hydrogen sensors [J].
Lee, Eunyeong ;
Lee, Junmin ;
Noh, Jin-Seo ;
Kim, Wonkyung ;
Lee, Taeyoon ;
Maeng, Sunglyul ;
Lee, Wooyoung .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2012, 37 (19) :14702-14706
[20]   Low energy hydrogen sensor [J].
Linke, S. ;
Dallmer, M. ;
Werner, R. ;
Moritz, W. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2012, 37 (22) :17523-17528