Examination of Human Meibum Collection and Extraction Techniques

被引:13
作者
Haworth, Kristina M. [1 ]
Nichols, Jason J. [1 ]
Thangavelu, Mirunalni [1 ]
Sinnott, Loraine T. [1 ]
Nichols, Kelly K. [1 ]
机构
[1] Ohio State Univ, Coll Optometry, Columbus, OH 43210 USA
关键词
lipids; dry eye; meibomian gland; collection devices; evaluation methods; MEIBOMIAN GLAND SECRETIONS; MASS-SPECTROMETRIC ANALYSIS; ENZYMATIC DETERMINATION; LIPIDS; CHROMATOGRAPHY; PHOSPHOLIPIDS; POLAR; EYE; IDENTIFICATION; CHOLESTEROL;
D O I
10.1097/OPX.0b013e318214ac0f
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To compare various meibum collection methods and extraction techniques. Methods. Sixty subjects, all successful contact lens wearers, were seen on two visits. Meibum was collected from the lower lid of the right eye with a glass microcapillary tube, and with a Dacron swab, cytology microbrush, or spatula from the left eye. Extraction with 2: 1 chloroform: methanol was done either immediately or after data collection was complete. Individual samples were divided into four equal aliquots for analysis of total lipids, cholesterol, and inorganic phosphates by assay-based techniques. Effects of collection method, extraction, and dry eye status were examined using repeated measures analysis of variance and logistic regression. Results. Total lipids showed significance for collection device (p < 0.0001) but not for extraction technique (p = 0.13) or dry eye status (p = 0.97). Dacron swab collection was associated with more total lipid on average than each other collection device (p < 0.0001). The cholesterol assay showed significance of collection device (p < 0.0001) and extraction technique (p = 0.0002) but not dry eye status (p = 0.55). Spatula collection was associated with more cholesterol on average than each other collection device (p < 0.0001). For inorganic phosphates, immediate extraction (p < 0.0001), cytology microbrush collection (p < 0.0001), and non-dry eye status (p = 0.03) were associated with the greater likelihood of detection. Conclusions. Dacron swab collection was associated with the highest average amount of total lipid detected, whereas spatula collection and immediate extraction was associated with the highest average amount of cholesterol detected. Cytology microbrush collection with immediate extraction on non-dry eye subjects was associated with the highest probability of detection of inorganic phosphates. (Optom Vis Sci 2011; 88: 525-533)
引用
收藏
页码:525 / 533
页数:9
相关论文
共 38 条
  • [1] ALLAIN CC, 1974, CLIN CHEM, V20, P470
  • [2] Manual tunnel incision extracapsular cataract extraction using the sandwich technique
    Bayramlar, H
    Çekiç, O
    Totan, Y
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (03) : 312 - 315
  • [3] BAZAN HEP, 1985, INVEST OPHTH VIS SCI, V26, P474
  • [4] Spectroscopic evaluation of human tear lipids
    Borchman, Douglas
    Foulks, Gary N.
    Yappert, Marta C.
    Tang, Daxin
    Ho, Donghai V.
    [J]. CHEMISTRY AND PHYSICS OF LIPIDS, 2007, 147 (02) : 87 - 102
  • [5] Understanding and analyzing meibomian lipids - A review
    Butovich, Igor A.
    Millar, Thomas J.
    Ham, Bryan M.
    [J]. CURRENT EYE RESEARCH, 2008, 33 (5-6) : 405 - 420
  • [6] Lipids of human meibum: mass-spectrometric analysis and structural elucidation
    Butovich, Igor A.
    Uchiyama, Eduardo
    McCulley, James P.
    [J]. JOURNAL OF LIPID RESEARCH, 2007, 48 (10) : 2220 - 2235
  • [7] Liquid chromatography-mass spectrometric analysis of lipids present in human meibomian gland secretions
    Butovich, Igor A.
    Uchiyama, Eduardo
    Di Pascuale, Mario A.
    McCulley, James P.
    [J]. LIPIDS, 2007, 42 (08) : 765 - 776
  • [8] Gonçalves PF, 2008, J PERIODONTOL, V79, P323, DOI [10.1902/jop.2008.070327, 10.1902/jop.2008.070327 ]
  • [9] Green-Church KB, 2008, MOL VIS, V14, P456
  • [10] Phospholipids in meibomian gland secretion
    Greiner, JV
    Glonek, T
    Korb, DR
    Booth, R
    Leahy, CD
    [J]. OPHTHALMIC RESEARCH, 1996, 28 (01) : 44 - 49