Chromium hexacyanoferrate modified biosensor based on PQQ-dependent glucose dehydrogenase

被引:2
|
作者
Tseng, Ta-Feng [1 ]
Yang, Yang-Li [1 ]
Lou, Shyh-Liang [1 ]
机构
[1] Chung Yuan Christian Univ, Dept Biomed Engn, Ctr Nanotechnol, Chungli 32023, Taiwan
来源
2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16 | 2007年
关键词
D O I
10.1109/IEMBS.2007.4352881
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A Pyrroloquinoline quinone (PQQ)-dependent glucose dehydrogenase based platinum electrode was developed to detect glucose. Chromium hexacyanoferrate was modified onto this electrode to serve as an electron transfer mediator between PQQ and the platinum electrode. This biosensor showed the optimal response of glucose measurements at pH 7 and an operation potential of +0.4 V (vs. Ag/AgCl). More importantly the lifespan of the biosensor has been last for 47 days without significant enzyme activity degradation.
引用
收藏
页码:2681 / 2684
页数:4
相关论文
共 50 条
  • [1] Effects of Electric Potential Treatment of a Chromium Hexacyanoferrate Modified Biosensor Based on PQQ-Dependent Glucose Dehydrogenase
    Tseng, Ta-Feng
    Yang, Yang-Li
    Lin, Yuh-Jiuan
    Lou, Shyh-Liang
    SENSORS, 2010, 10 (07): : 6347 - 6360
  • [2] Oxygen insensitive glucose biosensor based on PQQ-dependent glucose dehydrogenase
    Laurinavicius, V
    Kurtinaitiene, B
    Liauksminas, V
    Ramanavicius, A
    Meskys, R
    Rudomanskis, R
    Skotheim, T
    Boguslavsky, L
    ANALYTICAL LETTERS, 1999, 32 (02) : 299 - 316
  • [3] Bioelectrochemical sensor based on PQQ-dependent glucose dehydrogenase
    Malinauskas, A
    Kuzmarskyte, J
    Meskys, R
    Ramanavicius, A
    SENSORS AND ACTUATORS B-CHEMICAL, 2004, 100 (03): : 387 - 394
  • [4] Direct bioelectrocatalysis of PQQ-dependent glucose dehydrogenase
    Ivnitski, Dmitri
    Atanassov, Plamen
    Apblett, Christopher
    ELECTROANALYSIS, 2007, 19 (15) : 1562 - 1568
  • [5] Conducting redoxpolymer-based reagentless biosensors using modified PQQ-dependent glucose dehydrogenase
    Habermüller, K
    Reiter, S
    Buck, H
    Meier, T
    Staepels, J
    Schuhmann, W
    MICROCHIMICA ACTA, 2003, 143 (2-3) : 113 - 121
  • [6] Amperometric Microbiosensors Based on PQQ-Dependent Glucose Dehydrogenase towards the Development of an ATP Biosensor for in vitro Analysis
    Weber, C.
    Gauda, E.
    Hecht, E.
    Mizaikoff, B.
    Kranz, C.
    MICRO-AND NANOSYSTEMS IN MEDICINE, ACTIVE IMPLANTS, BIOSENSORS, 2009, 25 (08): : 351 - +
  • [7] FUNCTIONAL ANALYSIS OF THERMOSTABLE PQQ-DEPENDENT GLUCOSE DEHYDROGENASE
    Mikawa, Tsutomu
    Kagawa, Ako
    Kitaura, Kayo
    Kigawa, Takanori
    PROTEIN SCIENCE, 2019, 28 : 34 - 35
  • [8] Conducting Redoxpolymer-Based Reagentless Biosensors Using Modified PQQ-Dependent Glucose Dehydrogenase
    Katja Habermüller
    Sabine Reiter
    Harvey Buck
    Thomas Meier
    Johnny Staepels
    Wolfgang Schuhmann
    Microchimica Acta, 2003, 143 : 113 - 121
  • [9] Structure and mechanism of soluble glucose dehydrogenase and other PQQ-dependent enzymes
    Oubrie, A
    BIOCHIMICA ET BIOPHYSICA ACTA-PROTEINS AND PROTEOMICS, 2003, 1647 (1-2): : 143 - 151
  • [10] Chromium hexacyanoferrate based glucose biosensor
    Lin, MS
    Shih, WC
    ANALYTICA CHIMICA ACTA, 1999, 381 (2-3) : 183 - 189