Therapeutic monitoring of imipramine and desipramine by micellar liquid chromatography with direct injection and electrochemical detection

被引:24
作者
Bose, D
Martinavarro-Domínguez, A
Gil-Agustí, M
Carda-Broch, S
Durgbanshi, A
Capella-Peiró, ME
Esteve-Romero, J
机构
[1] Univ Jaume 1, Area Quim Anal, Castellon de La Plana 12071, Spain
[2] Hosp Verge Lliris, Serv Anal Clin, Alcoy 03804, Alacant, Spain
关键词
micellar liquid chromatography (MLC); imipramine; desipramine; serum; monitoring;
D O I
10.1002/bmc.455
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A micellar liquid chromatographic (MLC) procedure was developed for the clinical monitoring of imipramine and its active metabolite, desipramine. The determination of these highly hydrophobic substances was carried out after direct injection of the serum samples using a mobile phase composed of 0.15 m SDS-6% (v/v) pentanol buffered at pH 7, pumped at 1.5 mL/min into a C-18 column (250 x 4.6 mm), and electrochemical detection at 650 mV. Using this MLC method, calibration was linear (r > 0.995) and the limits of detection (ng/mL) were 0.34 and 0.24 for imipramine and desipramine, respectively. Repeatabilities and intermediate precision were tested at three different concentrations in the calibration range and a CV (%) below 2.2 was obtained. In this MLC procedure, the serum is determined without treatment, thus allowing repeated serial injections without changes in retention factors, and reducing the time and consumables required to carry out the pretreatment process. The assay method can be applied to the routine determination of serum imipramine and its metabolite in therapeutic drug monitoring. Copyright (c) 2004 John Wiley & Sons, Ltd.
引用
收藏
页码:343 / 349
页数:7
相关论文
共 27 条
[1]  
*AHFS, 1998, AM HOSP FORM SERV
[2]   PARTITIONING BEHAVIOR OF SOLUTES ELUTED WITH MICELLAR MOBILE PHASES IN LIQUID-CHROMATOGRAPHY [J].
ARMSTRONG, DW ;
NOME, F .
ANALYTICAL CHEMISTRY, 1981, 53 (11) :1662-1666
[3]   Causes and remediation of reduced efficiency in micellar liquid chromatography [J].
Berthod, A .
JOURNAL OF CHROMATOGRAPHY A, 1997, 780 (1-2) :191-206
[4]   SENSITIVE DETERMINATION IN PLASMA OF IMIPRAMINE AND DESIPRAMINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING ELECTROCHEMICAL DETECTION [J].
BOUQUET, S ;
GUYON, S ;
CHAPELLE, G ;
PERAULT, MC ;
BARTHES, D .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (11) :1993-2004
[5]   Direct injection micellar liquid chromatographic determination of benzodiazepines in serum [J].
Capella-Peiró, ME ;
Bose, D ;
Martinavarro-Domínguez, A ;
Gil-Agustí, M ;
Esteve-Romero, J .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 780 (02) :241-249
[6]   Determination in serum of some barbiturates using micellar liquid chromatography with direct injection [J].
Capella-Peiró, ME ;
Gil-Agustí, M ;
Martinavarro-Domínguez, A ;
Esteve-Romero, J .
ANALYTICAL BIOCHEMISTRY, 2002, 309 (02) :261-268
[7]   Analysis of urine samples containing cardiovascular drugs by micellar liquid chromatography with fluorimetric detection [J].
Carda-Broch, S ;
Rapado-Martínez, I ;
Esteve-Romero, O ;
García-Alvarez-Coque, MC .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1999, 37 (04) :93-102
[8]  
Chen Y, 2002, WAT STUD SER, V10, P153
[9]  
Chen ZL, 1997, ANAL LETT, V30, P2315
[10]  
FOGLIA JP, 1991, J CHROMATOGR B, V110, P247