Periovulatory Follicular Volume and Vascularization Determined by 3D and Power Doppler Sonography as Pregnancy Predictors in Intrauterine Insemination Cycles

被引:7
|
作者
Engels, Virginia [1 ]
Sanfrutos, Luis [1 ]
Perez-Medina, Tirso [1 ]
Alvarez, Pilar [1 ]
Zapardiel, Ignacio [1 ]
Godoy-Tundidor, Sonia [1 ]
Salazar, Francisco J. [1 ]
Troyano, Juan [2 ]
Bajo-Arenas, Jose M. [1 ]
机构
[1] Santa Cristina Univ Hosp, Dept Gynecol, Madrid, Spain
[2] Tenerife Univ Hosp, Dept Gynecol, Canary Isl, Spain
关键词
follicular volume; 3D power Doppler; vascular indexes; intrauterine insemination; ovaries; IN-VITRO FERTILIZATION; BLOOD-FLOW; 3-DIMENSIONAL ULTRASONOGRAPHY; OVARIAN VOLUME; QUANTIFICATION; ANGIOGRAPHY; RESPONDERS; INDEXES; SIGNAL;
D O I
10.1002/jcu.20816
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Purpose. To evaluate the relationship between volume and vascularization of the periovulatory follicle and subfollicular area measured by three-dimensional power Doppler ultrasound (US), and ovulation and pregnancy in patients undergoing intrauterine insemination (IUI). Methods. We studied 79 consecutive cycles of IUI on hCG administration day. We measured the periovulatory follicle and subfollicular area by means of three-dimensional power Doppler US. The stored volumes were processed with the VOCAL image processing software to calculate the volume of the follicle and the following vascular indices: vascularization index (VI), flow index (FI), and vascularization flow index (VFI). Results. The follicular volume was higher in anovulatory cycles (7.7 +/- 3.7 cubic centimeters (CC) versus 4.1 +/- 2.0 CC; p < 0.001). There was no difference between the follicular volumes in cycles with or without subsequent pregnancy. The vascular indices of the follicle did not differ significantly between ovulatory and anovulatory cycles, and between cycles that did and did not achieve pregnancy. Periovulatory subfollicular VI and VFI were lower in women who became pregnant (VI: 2.9 +/- 2.3% versus 5.6 +/- 4.6%; p < 0.05, and VFI: 1.1 +/- 0.8 versus 2.2 +/- 2.2; p < 0.01). Conclusions. High values of follicular volume were associated with anovulatory cycles. Subfollicular VI and VFI might be used as markers of follicular quality and pregnancy predictors. (C) 2011 Wiley Periodicals, Inc. J Clin Ultrasound 39:243-247, 2011; Published online in Wiley Online Library (wileyonlinelibrary.com). DOI: 10.1002/jcu.20816
引用
收藏
页码:243 / 247
页数:5
相关论文
共 50 条
  • [41] Power Doppler and 3D vascular sonography of the intraprostatic blood supply: assessment criteria and value for diagnosis and staging of prostate cancer.
    Sauvain, JL
    Palascak, P
    Bourscheid, D
    Bloqueau, P
    Bremon, JM
    Jung, L
    Maniere, P
    PROGRES EN UROLOGIE, 2000, 10 (02): : 237 - 245
  • [42] Pre-surgical evaluation of ICA-stenosis using 3D power Doppler, 3D color coded Doppler sonography, 3D B-flow and contrast enhanced B-flow in correlation to CTA/MRA: First clinical results
    Pfister, K.
    Rennert, J.
    Greiner, B.
    Jung, W.
    Stehr, A.
    Goessmann, H.
    Menzel, C.
    Zorger, N.
    Prantl, L.
    Feuerbach, S.
    Kasprzak, P.
    Jung, E. M.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2009, 41 (02) : 103 - 116
  • [43] Evaluation of the relationship between renal function and renal volume-vascular indices using 3D power Doppler ultrasound
    Cansu, Aysegul
    Kupeli, Ali
    Kul, Sibel
    Eyuboglu, Ilker
    Oguz, Sukru
    Ozturk, Mehmet Halil
    DincKaradeniz, Hasan
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (07) : 1080 - 1085
  • [44] Role of first-trimester three-dimensional (3D) power Doppler of placental blood flow and 3D placental volume in early prediction of pre-eclampsia
    Abdallah, Ameer
    Khairy, Mohammed
    Tawfik, Mohamed
    Mohamed, Safaa
    Abdel-Rasheed, Mazen
    Salem, Sondos
    Khalifa, Eissa
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2021, 154 (03) : 466 - 473
  • [45] First-Trimester 3-Dimensional Power Doppler Placental Vascularization Indices From the Whole Placenta Versus the Placental Bed to Predict Preeclampsia Does Pregnancy-Associatec Plasma Protein A or Uterine Artery Doppler Sonography Help?
    Hannaford, Karen E.
    Tuuli, Methodius
    Goetzinger, Katherine R.
    Odibo, Linda
    Cahill, Alison G.
    Macones, George
    Odibo, Anthony O.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2015, 34 (06) : 965 - 970
  • [46] The Influence of Hyperoxygenation on Fetal Brain Vascularity Measured Using 3D Power Doppler Ultrasound and the Index "Fractional Moving Blood Volume"
    Issa, Evitta
    Stevenson, Gordon Niall
    Gomes De Melo Tavares Ferreira, Ana Elizabeth
    Chang, Melissa Han Yiin
    Alphonse, Jennifer
    Welsh, Alec William
    FETAL DIAGNOSIS AND THERAPY, 2021, 48 (09) : 651 - 659
  • [47] The use of 3D rendering, VCI-C, 3D power Doppler and B-flow in the evaluation of interstitial pregnancy with, arteriovenous malformation treated by selective uterine artery embolization
    Valsky, D. V.
    Hamani, Y.
    Verstandig, A.
    Yagel, S.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2007, 29 (03) : 352 - 355
  • [48] The role of sub-chorionic blood flow measured by 3D power Doppler ultrasonography in the prediction of pregnancy outcome: a preliminary study
    Huang, J.
    Cheung, W.
    Chen, X.
    Liu, Y.
    Saravelos, S.
    Li, T. C.
    HUMAN REPRODUCTION, 2018, 33 : 346 - 346
  • [49] PLACENTAL HEMODYNAMIC ASSESSMENT IN WOMEN WITH SEVERE PREECLAMPSIA IN SECOND- AND THIRD-TRIMESTER PREGNANCY BY 3D POWER QUANTITATIVE DOPPLER ULTRASOUND
    Zhou, Sufen
    An, Peng
    Lian, Kai
    Gan, Ling
    Feng, Wei
    Song, Juan
    Wang, Yu
    Liu, Xinyi
    Li, Mengxue
    Zhang, Yanting
    Zhang, Xianya
    Zhang, Shunyu
    Chen, Yuting
    Wan, Shuya
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2020, 20 (09)
  • [50] High-grade stenoses of the internal carotid artery: Comparison of high-resolution contrast enhanced 3D MRA, duplex sonography and power Doppler imaging
    Clevert, D. -A.
    Johnson, T.
    Michaely, H.
    Jung, E. M.
    Flach, P. M.
    Strautz, T. I.
    Clevert, D. -A.
    Reiser, M.
    Schoenberg, S. O.
    EUROPEAN JOURNAL OF RADIOLOGY, 2006, 60 (03) : 379 - 386