Periovulatory Follicular Volume and Vascularization Determined by 3D and Power Doppler Sonography as Pregnancy Predictors in Intrauterine Insemination Cycles

被引:7
|
作者
Engels, Virginia [1 ]
Sanfrutos, Luis [1 ]
Perez-Medina, Tirso [1 ]
Alvarez, Pilar [1 ]
Zapardiel, Ignacio [1 ]
Godoy-Tundidor, Sonia [1 ]
Salazar, Francisco J. [1 ]
Troyano, Juan [2 ]
Bajo-Arenas, Jose M. [1 ]
机构
[1] Santa Cristina Univ Hosp, Dept Gynecol, Madrid, Spain
[2] Tenerife Univ Hosp, Dept Gynecol, Canary Isl, Spain
关键词
follicular volume; 3D power Doppler; vascular indexes; intrauterine insemination; ovaries; IN-VITRO FERTILIZATION; BLOOD-FLOW; 3-DIMENSIONAL ULTRASONOGRAPHY; OVARIAN VOLUME; QUANTIFICATION; ANGIOGRAPHY; RESPONDERS; INDEXES; SIGNAL;
D O I
10.1002/jcu.20816
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Purpose. To evaluate the relationship between volume and vascularization of the periovulatory follicle and subfollicular area measured by three-dimensional power Doppler ultrasound (US), and ovulation and pregnancy in patients undergoing intrauterine insemination (IUI). Methods. We studied 79 consecutive cycles of IUI on hCG administration day. We measured the periovulatory follicle and subfollicular area by means of three-dimensional power Doppler US. The stored volumes were processed with the VOCAL image processing software to calculate the volume of the follicle and the following vascular indices: vascularization index (VI), flow index (FI), and vascularization flow index (VFI). Results. The follicular volume was higher in anovulatory cycles (7.7 +/- 3.7 cubic centimeters (CC) versus 4.1 +/- 2.0 CC; p < 0.001). There was no difference between the follicular volumes in cycles with or without subsequent pregnancy. The vascular indices of the follicle did not differ significantly between ovulatory and anovulatory cycles, and between cycles that did and did not achieve pregnancy. Periovulatory subfollicular VI and VFI were lower in women who became pregnant (VI: 2.9 +/- 2.3% versus 5.6 +/- 4.6%; p < 0.05, and VFI: 1.1 +/- 0.8 versus 2.2 +/- 2.2; p < 0.01). Conclusions. High values of follicular volume were associated with anovulatory cycles. Subfollicular VI and VFI might be used as markers of follicular quality and pregnancy predictors. (C) 2011 Wiley Periodicals, Inc. J Clin Ultrasound 39:243-247, 2011; Published online in Wiley Online Library (wileyonlinelibrary.com). DOI: 10.1002/jcu.20816
引用
收藏
页码:243 / 247
页数:5
相关论文
共 50 条
  • [1] Evaluation of Endometrial and Subendometrial Vascularization and Endometrial Volume by 3-D Power Doppler Ultrasound and Its Relationship with Age and Pregnancy in Intrauterine Insemination Cycles
    Engels, V.
    Sanfrutos, L.
    Perez-Medina, T.
    Alvarez, P.
    Zapardiel, I.
    Bueno, B.
    Godoy-Tundidor, S.
    Bajo-Arenas, J. M.
    GYNECOLOGIC AND OBSTETRIC INVESTIGATION, 2011, 72 (02) : 117 - 122
  • [2] 3D vocal power Doppler sonography for the estimation of tumor volume and vascularization in stage IB1 cervical cancer
    George Daskalakis
    Diamantis Diamantopoulos
    Mariana Theodora
    Anysia Semertzidou
    Kaliopi Pappa
    Panagiotis Antsaklis
    Mihail Sindos
    Alexandros Rodolakis
    Konstantinos Kalmantis
    Archives of Gynecology and Obstetrics, 2018, 298 : 617 - 622
  • [3] 3D vocal power Doppler sonography for the estimation of tumor volume and vascularization in stage IB1 cervical cancer
    Daskalakis, George
    Diamantopoulos, Diamantis
    Theodora, Mariana
    Semertzidou, Anysia
    Pappa, Kaliopi
    Antsaklis, Panagiotis
    Sindos, Mihail
    Rodolakis, Alexandros
    Kalmantis, Konstantinos
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2018, 298 (03) : 617 - 622
  • [4] 3D power Doppler vascularization indexes are not predictive for pregnancy outcome on IVF/ICSI patients
    Sanhueza, P.
    Donoso, P.
    Salinas, R.
    Enriquez, R.
    Saez, V.
    Carrasco, I.
    Rios, M.
    Gonzalez, P.
    HUMAN REPRODUCTION, 2011, 26 : I237 - I237
  • [5] Assessment of endometrial volume and vascularization using transvaginal 3D power Doppler angiography in women with postmenopausal bleeding
    Rossi, Alberto
    Forzano, Leonardo
    Romanello, Irene
    Fachechi, Giorgio
    Marchesoni, Diego
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2012, 119 (01) : 14 - 17
  • [6] Placental volume and vascular flow assessed by 3D power Doppler and adverse pregnancy outcomes
    Odibo, A. O.
    Goetzinger, K. R.
    Huster, K. M.
    Christiansen, J. K.
    Odibo, L.
    Tuuli, M. G.
    PLACENTA, 2011, 32 (03) : 230 - 234
  • [7] 3D power Doppler vascularization indices of the whole placenta vs placental bed in the prediction of adverse pregnancy outcomes
    Hannaford, Karen
    Goetzinger, Katherine
    Tuuli, Methodius
    Odibo, Linda
    Cahill, Alison
    Macones, George
    Odibo, Anthony
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2014, 210 (01) : S95 - S96
  • [8] Study of Intraplacental Vascularization by 3D Power Doppler Ultrasound in Pregnancies with Normal Evolution
    Mihu, Carmen Mihaela
    Mihu, Dan
    Drugan, Tudor
    Dudea, Sorin
    Ciortea, Razvan
    Oancea, Mihaela
    GINECO RO, 2010, 6 (04): : 210 - 216
  • [9] Variations of the Origin of Renal Arteries in the Fetus Identified on Power Doppler and 3D Sonography
    Degani, Shimon
    Leibovitz, Zvi
    Shapiro, Israel
    Ohel, Gonen
    JOURNAL OF CLINICAL ULTRASOUND, 2010, 38 (02) : 59 - 65
  • [10] The assessment of fetal brain morphology and circulation by transvaginal 3D sonography and power Doppler
    Pooh, RK
    Pooh, KH
    JOURNAL OF PERINATAL MEDICINE, 2002, 30 (01) : 48 - 56