The Glasgow-Maastricht foot model, evaluation of a 26 segment kinematic model of the foot

被引:15
作者
Oosterwaal, Michiel [1 ,2 ]
Carbes, Sylvain [3 ]
Telfer, Scott [4 ]
Woodburn, James [4 ]
Torholm, Soren [3 ]
Al-Munajjed, Amir A. [3 ]
van Rhijn, Lodewijk [2 ]
Meijer, Kenneth [1 ]
机构
[1] Maastricht Univ, Dept Human Movement Sci, NUTRIM, Med Ctr, PO 5800, NL-6202 AZ Maastricht, Netherlands
[2] Maastricht Univ, Med Ctr, CAPHRI, Dept Orthopaed Surg, PO 5800, NL-6202 AZ Maastricht, Netherlands
[3] AnyBody Technol AS, Niels Jernes Vej 10, DK-9220 Aalborg, Denmark
[4] Glasgow Caledonian Univ, Inst Appl Hlth Res, Cowcaddens Rd, Glasgow, Lanark, Scotland
来源
JOURNAL OF FOOT AND ANKLE RESEARCH | 2016年 / 9卷
关键词
Kinematic foot model; Multi-segment foot model; Gait analysis; STANCE PHASE; MOTION; WALKING; GAIT; REPEATABILITY; POSTERIOR; REARFOOT; FOREFOOT; DESIGN;
D O I
10.1186/s13047-016-0152-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Accurately measuring of intrinsic foot kinematics using skin mounted markers is difficult, limited in part by the physical dimensions of the foot. Existing kinematic foot models solve this problem by combining multiple bones into idealized rigid segments. This study presents a novel foot model that allows the motion of the 26 bones to be individually estimated via a combination of partial joint constraints and coupling the motion of separate joints using kinematic rhythms. Methods: Segmented CT data from one healthy subject was used to create a template Glasgow-Maastricht foot model (GM-model). Following this, the template was scaled to produce subject-specific models for five additional healthy participants using a surface scan of the foot and ankle. Forty-three skin mounted markers, mainly positioned around the foot and ankle, were used to capture the stance phase of the right foot of the six healthy participants during walking. The GM-model was then applied to calculate the intrinsic foot kinematics. Results: Distinct motion patterns where found for all joints. The variability in outcome depended on the location of the joint, with reasonable results for sagittal plane motions and poor results for transverse plane motions. Conclusions: The results of the GM-model were comparable with existing literature, including bone pin studies, with respect to the range of motion, motion pattern and timing of the motion in the studied joints. This novel model is the most complete kinematic model to date. Further evaluation of the model is warranted.
引用
收藏
页数:10
相关论文
共 22 条
  • [1] Andersen MS, 2009, SPECIAL REPORT
  • [2] A 3-DIMENSIONAL KINEMATIC AND DYNAMIC-MODEL OF THE LOWER-LIMB
    APKARIAN, J
    NAUMANN, S
    CAIRNS, B
    [J]. JOURNAL OF BIOMECHANICS, 1989, 22 (02) : 143 - 155
  • [3] A three-dimensional shank-foot model to determine the foot motion during landings
    Arampatzis, A
    Brüggemann, GP
    Klapsing, GM
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2002, 34 (01) : 130 - 138
  • [4] Buhmann M. D., RADIAL BASIS FUNCTIO
  • [5] Kinematic analysis of a multi-segment foot model for research and clinical applications: a repeatability analysis
    Carson, MC
    Harrington, ME
    Thompson, N
    O'Connor, JJ
    Theologis, TN
    [J]. JOURNAL OF BIOMECHANICS, 2001, 34 (10) : 1299 - 1307
  • [6] Davis RB, 2008, BIOMED ENG SER, P425
  • [7] A clinically applicable six-segmented foot model
    De Mits, Sophie
    Segers, Veerle
    Woodburn, Jim
    Elewaut, Dirk
    De Clercq, Dirk
    Roosen, Philip
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2012, 30 (04) : 655 - 661
  • [8] Body of evidence supporting the clinical use of 3D multisegment foot models: A systematic review
    Deschamps, Kevin
    Staes, Filip
    Roosen, Philip
    Nobels, Frank
    Desloovere, Kaat
    Bruyninckx, Herman
    Matricali, Giovanni A.
    [J]. GAIT & POSTURE, 2011, 33 (03) : 338 - 349
  • [9] Inter-segment foot motion and ground reaction forces over the stance phase of walking
    Hunt, AE
    Smith, RM
    Torode, M
    Keenan, AM
    [J]. CLINICAL BIOMECHANICS, 2001, 16 (07) : 592 - 600
  • [10] Marker-based validation of a biplane fluoroscopy system for quantifying foot kinematics
    Iaquinto, Joseph M.
    Tsai, Richard
    Haynor, David R.
    Fassbind, Michael J.
    Sangeorzan, Bruce J.
    Ledoux, William R.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2014, 36 (03) : 391 - 396