Multivariate data analysis for Raman imaging of a model pharmaceutical tablet

被引:168
作者
Zhang, L [1 ]
Henson, MJ [1 ]
Sekulic, SS [1 ]
机构
[1] Pfizer Global R&D, Analyt Res & Dev, Groton, CT 06340 USA
关键词
Raman imaging; PCA cluster analysis; DCLS; multivariate curve resolutions; pharmaceutical tablet;
D O I
10.1016/j.aca.2005.04.080
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Spectroscopic imaging techniques provide spatial and spectral information about a sample simultaneously and are finding ever-increasing application in the pharmaceutical industry. Effective extraction of chemical information from imaging data sets is a crucial step during the application of imaging techniques. Multivariate imaging data analysis methods have been reported but few applications of these methods for pharmaceutical samples have been demonstrated. In this study, a bilayer model tablet consisting of avicel, lactose. sodium benzoate, magnesium stearate and red dye was prepared using custom press tooling, and Raman mapping data were collected from a 400 mu m x 400 mu m area of the tablet surface. Several representative multivariate methods were selected and used in the analysis of the data, Multivariate data analysis methods investigated include principal component analysis (PCA). cluster analysis, direct classical least squares (DCLS) and multivariate curve resolution (MCR). The relative merits and drawbacks of each technique for this application were evaluated. In addition, some practical issues associated with the use of these methods were addressed including data preprocessing. determination of the optimal number of clusters in cluster analysis and the optimization of window size in second derivative calculation. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:262 / 278
页数:17
相关论文
共 50 条
  • [1] Rapid analysis of Raman image data using two-way multivariate curve resolution
    Andrew, JJ
    Hancewicz, TM
    [J]. APPLIED SPECTROSCOPY, 1998, 52 (06) : 797 - 807
  • [2] [Anonymous], 1989, MULTIVARIATE CALIBRA
  • [3] [Anonymous], Pattern Recognition With Fuzzy Objective Function Algorithms
  • [4] STANDARD NORMAL VARIATE TRANSFORMATION AND DE-TRENDING OF NEAR-INFRARED DIFFUSE REFLECTANCE SPECTRA
    BARNES, RJ
    DHANOA, MS
    LISTER, SJ
    [J]. APPLIED SPECTROSCOPY, 1989, 43 (05) : 772 - 777
  • [5] Self-modeling mixture analysis of Raman microspectrometric investigations of dust emitted by lead and zinc smelters
    Batonneau, Y
    Laureyns, J
    Merlin, JC
    Brémard, C
    [J]. ANALYTICA CHIMICA ACTA, 2001, 446 (1-2) : 23 - 37
  • [6] Bro R, 1997, J CHEMOMETR, V11, P393, DOI 10.1002/(SICI)1099-128X(199709/10)11:5<393::AID-CEM483>3.3.CO
  • [7] 2-C
  • [8] Application of Multivariate curve resolution for analysis of FT-IR microspectroscopic images of in situ plant tissue
    Budevska, BO
    Sum, ST
    Jones, TJ
    [J]. APPLIED SPECTROSCOPY, 2003, 57 (02) : 124 - 131
  • [9] *CHEM INC, 2001, CHEM 6 0 US MAN
  • [10] Determination of the information depth and sample size for the analysis of pharmaceutical materials using reflectance near-infrared microscopy
    Clarke, FC
    Hammond, SV
    Jee, RD
    Moffat, AC
    [J]. APPLIED SPECTROSCOPY, 2002, 56 (11) : 1475 - 1483