Online control of current-source-type active rectifier using transfer function approach

被引:11
作者
Graovac, D [1 ]
Katic, V [1 ]
机构
[1] Univ Novi Sad, Fac Engn, Inst Power Elect & Telecommun Engn, YU-21000 Novi Sad, Yugoslavia
关键词
AC/DC power conversion; estimation; filters; harmonic distortion; online control;
D O I
10.1109/41.925579
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Current-source topology ac/dc converters (buck converters) operated using pulsewidth modulation have significant drawbacks in lack of line current control and at-side filter damping, Also, an ac-side filter is usually overrated in order to keep harmonic distortion under imposed Limits. Discontinuous current at converter line inputs disables the use of current control techniques known from control of voltage-source converters. In order to overcome these problems, an online control method for the buck converter is presented in this paper, This method is based on the ac filter transfer function approach. Such approach enables a novel solution for line-side filter optimization in the case of hysteresis line current control, This method leads to a biter with minimal apparent power (cost) and the fast and accurate converter's control response. Furthermore, a line current estimation method was developed. It uses only one current sensor at the converter dc side in order to estimate power supply currents. Suggested methods were numerically and experimentally verified.
引用
收藏
页码:526 / 535
页数:10
相关论文
共 18 条
[1]   Single current sensor technique in the DC link of three-phase PWM-VS inverters: A review and a novel solution [J].
Blaabjerg, F ;
Pedersen, JK ;
Jaeger, U ;
Thoegersen, P .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (05) :1241-1253
[2]  
Espinoza J., 1993, ISIE'93 - Budapest. IEEE International Symposium on Industrial Electronics. Conference Proceedings (Cat.No.93TH0540-5), P674, DOI 10.1109/ISIE.1993.268723
[3]   ON MAXIMIZING GAIN AND MINIMIZING SWITCHING FREQUENCY OF DELTA-MODULATED INVERTERS [J].
JOOS, G ;
ZIOGAS, PD .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1993, 40 (04) :436-444
[4]   A Model Reference Adaptive PWM Technique [J].
Joos, Geza ;
Ziogas, Phoivos D. ;
Vincenti, Donato .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1990, 5 (04) :485-494
[5]  
KATIC V, 1990, P IEEE 1 INT C APPL, P38
[6]  
LEVINE WS, 1996, CONTROL HDB, pCH10
[7]   3-PHASE AC/DC PWM CONVERTER WITH SINUSOIDAL AC CURRENTS AND MINIMUM FILTER REQUIREMENTS [J].
MALESANI, L ;
TENTI, P .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1987, 23 (01) :71-77
[8]   Review of high-performance three-phase power-factor correction circuits [J].
Mao, HC ;
Lee, FCY ;
Boroyevich, D ;
Hiti, S .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1997, 44 (04) :437-446
[9]  
Phipps J. K., 1997, IEEE Industry Applications Magazine, V3, P68, DOI 10.1109/2943.579139
[10]  
RASTOGI M, 1993, IAS 93, PTS 1-3, P971, DOI 10.1109/IAS.1993.299016