New Fault Detection Method for Single-Phase Autoreclosing

被引:18
作者
de Mattos, Leonardo M. N.
Tavares, Maria C. [1 ]
Mendes, Aniela Maria P. [2 ]
机构
[1] Univ Estadual Campinas, BR-13083970 Campinas, SP, Brazil
[2] Eletrobras Eletronorte, BR-70716901 Brasilia, DF, Brazil
基金
巴西圣保罗研究基金会;
关键词
Adaptive single-phase reclosing; open phase voltage prediction; unbalanced power flow; alternative transients program (ATP); EMTP simulation; TRANSMISSION-LINES; VOLTAGE; ALGORITHM; TIME;
D O I
10.1109/TPWRD.2018.2855105
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Single-phase autoreclosing (SPAR) is among the alternatives for mitigating the many harmful effects that a line-to-ground fault in a transmission line (TL) may cause. This procedure basically consists of opening the compromised phase, waiting a preset time span (dead time), and recomposing the previously isolated phase. In the vast majority of SPAR implementations, the open phase switching proceeds with no guarantee of whether the TL is still faulted. Switching the open phase into a fault might represent a more severe threat to the system than simply disconnecting the TL in the first place. Hence, in an effort to ensure higher levels of operational reliability to SPAR, the present paper offers a new methodology to check the soundness of the open phase during the dead time before its reclosing. First, the method's fundamental concepts are exposed. Second, a huge number of steady-state tests are presented, for which both the system topology and its operative condition were varied. To conclude, the SPAR is simulated in the time-domain with the most critical condition found in the steady-state analysis. The proposed strategy was capable of correctly identifying whether the system was faulted in every performed simulation.
引用
收藏
页码:2874 / 2883
页数:10
相关论文
共 31 条
[1]   An alternative approach to adaptive single pole auto-reclosing in high voltage transmission systems based on variable dead time control [J].
Ahn, SP ;
Kim, CH ;
Aggarwal, RK ;
Johns, AT .
IEEE TRANSACTIONS ON POWER DELIVERY, 2001, 16 (04) :676-686
[2]  
[Anonymous], 1964, IEEE T POWER AP SYST
[3]  
Ban G., 2001, 2001 IEEE Porto Power Tech Proceedings (Cat. No.01EX502), DOI 10.1109/PTC.2001.964819
[4]   New concept in transmission line reclosure using high-frequency fault transients [J].
Bo, ZQ ;
Aggarwal, RK ;
Johns, AT ;
Zhang, BH ;
Ge, YZ .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1997, 144 (04) :351-356
[5]  
Bo ZQ, 1997, FOURTH INTERNATIONAL CONFERENCE ON ADVANCES IN POWER SYSTEM CONTROL, OPERATION & MANAGEMENT, VOLS 1 AND 2, P216
[6]   Comparison between traditional single-phase auto reclosing and adaptive technique based on harmonic content measurement [J].
Dias, Ozenir ;
Tavares, Maria Cristina .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (04) :905-914
[7]   An adaptive single pole autoreclosure based on zero sequence power [J].
Elkalashy, Nagy I. ;
Darwish, Hatem A. ;
Taalab, Abdel-Maksoud I. ;
Izzularab, Mohmmad A. .
ELECTRIC POWER SYSTEMS RESEARCH, 2007, 77 (5-6) :438-446
[8]  
Elmore WalterA., 2004, Protective Relaying Theory and Applications, V2nd
[9]   SINGLE-PHASE TRIPPING AND AUTO RECLOSING OF TRANSMISSION-LINES IEEE COMMITTEE REPORT [J].
ESZTERGALYOS, J ;
ANDRICHAK, J ;
COLWELL, DH ;
DAWSON, DC ;
JODICE, JA ;
MURRAY, TJ ;
MUSTAPHI, KK ;
NAIL, GR ;
POLITIS, A ;
POPE, JW ;
ROCKEFELLER, GD ;
STRANNE, GP ;
TZIOUVARAS, D ;
SCHWEITZER, EO .
IEEE TRANSACTIONS ON POWER DELIVERY, 1992, 7 (01) :182-192
[10]  
Ferreira CMM, 1998, IEEE CONF R, P950, DOI 10.1109/MELCON.1998.699368