Lung at thin-section CT: Influence of multiple-segment reconstruction on image quality

被引:5
作者
Arac, M [1 ]
Oner, AY [1 ]
Celik, H [1 ]
Akpek, S [1 ]
Isik, S [1 ]
机构
[1] Gazi Univ, Sch Med, Dept Radiol, Ankara, Turkey
关键词
computed tomography (CT); artifact; image processing; lung; CT;
D O I
10.1148/radiol.2291020642
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate multiple-segment reconstruction to reduce cardiac-motion artifacts on thin-section computed tomographic (CT) images in the lung. MATERIALS AND METHODS: Fifty patients were enrolled in the study. All images were obtained with a scanner capable of 1-second revolution time. Routine lung thin-section CT examination was performed with images reconstructed with bone algorithm. Multiple-segment images reconstructed with lung algorithm were obtained for three levels in the left paracardiac region. Segment images were reconstructed retrospectively with data for 225degrees rotation rather than the 360degrees rotation used for a complete scan. To minimize differences resulting from reconstruction algorithms, additional nonsegmented reconstruction was performed with lung algorithm. Three radiologists reviewed each set of images and assigned a quality score. Multiway analysis of variance was performed to compare motion artifact reduction with 225degrees and 360degrees reconstructions. RESULTS: Differences were not significant (P > .05) between scores for images reconstructed with bone or lung algorithms. Differences were significant between scores for reconstructed images obtained with the combination of 360degrees bone and 225degrees segment algorithms (P < .001) and for those obtained with the combination of 360degrees lung and 225degrees segment algorithms (P < .001). CONCLUSION: Multiple-segment reconstruction of lung thin-section CT images is an effective technique for reducing cardiac-motion artifacts without increasing patient dose. (C) RSNA, 2003.
引用
收藏
页码:195 / 199
页数:5
相关论文
共 11 条
[1]   EVALUATION OF ULTRAFAST CT SCANNING OF THE ADULT ABDOMEN [J].
GOLDBERG, HI ;
GOULD, RG ;
FEUERSTEIN, IM ;
SIGETI, JS ;
LIPTON, MJ .
INVESTIGATIVE RADIOLOGY, 1989, 24 (07) :537-543
[2]  
GUTIERREZ FR, 1998, COMPUTED BODY TOMOGR, P183
[3]  
HEENON O, 1989, RADIOLOGY, V171, P572
[4]   CHRONIC INFILTRATIVE LUNG-DISEASE - COMPARISON OF DIAGNOSTIC ACCURACIES OF RADIOGRAPHY AND LOW-AND CONVENTIONAL-DOSE THIN-SECTION CT [J].
LEE, KS ;
PRIMACK, SL ;
STAPLES, CA ;
MAYO, JR ;
ALDRICH, JE ;
MULLER, NL .
RADIOLOGY, 1994, 191 (03) :669-673
[5]   Thin-section CT of the lung:: influence of 0.5-s gantry rotation and ECG triggering on image quality [J].
Montaudon, M ;
Berger, P ;
Blachère, H ;
De Boucaud, L ;
Latrabe, V ;
Laurent, F .
EUROPEAN RADIOLOGY, 2001, 11 (09) :1681-1687
[6]   PROSPECTIVELY GATED CARDIAC COMPUTED-TOMOGRAPHY [J].
MOORE, SC ;
JUDY, PF ;
GARNIC, JD ;
KAMBIC, GX ;
BONK, F ;
COCHRAN, G ;
MARGOSIAN, P ;
MCCROSKEY, W ;
FOOTE, F .
MEDICAL PHYSICS, 1983, 10 (06) :846-855
[7]   CT OF THE CHEST AND ABDOMEN IN PATIENTS ON MECHANICAL PULMONARY VENTILATORS - QUALITY OF IMAGES MADE AT 0.6-SEC VS 1.0-SEC [J].
POSNIAK, HV ;
OLSON, MC ;
DEMOS, TC ;
PIERCE, KL ;
KALBHEN, CL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (05) :1073-1077
[8]   Thoracic helical CT:: influence of subsecond scan time and thin collimation on evaluation of peripheral pulmonary arteries [J].
Rémy-Jardin, M ;
Baghaie, F ;
Bonnel, F ;
Masson, P ;
Duhamel, A ;
Rémy, J .
EUROPEAN RADIOLOGY, 2000, 10 (08) :1297-1303
[9]   MINIMUM SCAN SPEEDS FOR SUPPRESSION OF MOTION ARTIFACTS IN CT [J].
RITCHIE, CJ ;
GODWIN, JD ;
CRAWFORD, CR ;
STANFORD, W ;
ANNO, H ;
KIM, Y .
RADIOLOGY, 1992, 185 (01) :37-42
[10]   Thoracic spiral CT: Influence of subsecond gantry rotation on image quality [J].
Rubin, GD ;
Leung, AN ;
Robertson, VJ ;
Stark, P .
RADIOLOGY, 1998, 208 (03) :771-776