Laminated Glass Panels in Combination with Timber Frame as a Shear Wall in Earthquake Resistant Building Design

被引:6
作者
Antolinc, David [1 ]
Zarnic, Roko [1 ]
Cepon, Franci [1 ]
Rajcic, Vlatka [2 ]
Stepinac, Mislav [2 ]
机构
[1] Univ Ljubljana, Fac Civil & Geodet Engn, Ljubljana 61000, Slovenia
[2] Univ Zagreb, Fac Civil Engn, Zagreb 41000, Croatia
来源
CHALLENGING GLASS 3 | 2012年
关键词
Timber frame; laminated glass; dynamic load; seismic design; shear wall; in-plane stability;
D O I
10.3233/978-1-61499-061-1-623
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The idea of the present study is to determine the in-plane stiffness and load bearing capacity of timber frame with laminated glass infill which acts as a shear wall and finally to estimate the contribution of such wall to the overall behavior of the entire building. For this reason we conducted an in-plane cycling load-displacement experiment of above mentioned wall system. The shear wall is composed of cross laminated timber frame and heat strengthened laminated glass panels, which are connected just with friction without any adhesives. The consequence of this type of connection is that we get larger displacements at a certain applied load which means higher ductility of the whole wall. On the other hand we get the problem to achieve the serviceability limit state. The comparison of the experimental results obtained for different types of timber frame connection details is made. The numerical simulation using ABAQUS software has also been done which gave us inaccurate results due to the inadequate timber frame connection modeling. The plan for the improvement of numerical modeling is made based on the additional experimental analysis of the timber frame elements connections.
引用
收藏
页码:623 / 631
页数:9
相关论文
共 10 条
[1]  
Behr RA, 2001, 8 GLASS PROC DAYS C
[2]  
Freitag C, 2009, P GLASS PERF DAYS
[3]  
Huveners E.M.P., 2007, P 10 INT C TAMP GLAS
[4]  
McBean Peter, 2005, P ANN TECHN C AUSTR
[5]  
Memari Ali M., 2011, J ARCHITECTURAL ENG, V17
[6]  
Mocibob D, 2008, THESIS ECOLE POLYTEC
[7]  
Niedermaier P., 2003, GLASS PROC DAYS 2003
[8]   Development of a loading history for seismic testing of architectural glass in a shop-front wall system [J].
Pantelides, CP ;
Truman, KZ ;
Behr, RA ;
Belarbi, A .
ENGINEERING STRUCTURES, 1996, 18 (12) :917-935
[9]  
Sivanerupan S., 2009, P ANN TECHN C AUSTR
[10]   Behaviour of window glass panels during earthquakes [J].
Sucuoglu, H ;
Vallabhan, CVG .
ENGINEERING STRUCTURES, 1997, 19 (08) :685-694