Effect of CT scan protocols on x-ray-induced DNA double-strand breaks in blood lymphocytes of patients undergoing coronary CT angiography

被引:68
作者
Kuefner, M. A. [1 ]
Grudzenski, S. [2 ]
Hamann, J. [1 ]
Achenbach, S. [3 ]
Lell, Michael [1 ]
Anders, K. [1 ]
Schwab, S. A. [1 ]
Haeberle, L. [4 ]
Loebrich, M. [2 ]
Uder, M. [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Radiol, D-91054 Erlangen, Germany
[2] Tech Univ Darmstadt, Radiat Biol & DNA Repair, D-64287 Darmstadt, Germany
[3] Univ Erlangen Nurnberg, Dept Cardiol, D-91054 Erlangen, Germany
[4] Univ Erlangen Nurnberg, Dept Med Informat Biometry & Epidemiol, D-91054 Erlangen, Germany
关键词
Dual-source CT; CoronaryCTangiography; Biological dose; DNA double-strand breaks; gamma-H2AX; DUAL-SOURCE CT; MULTISLICE COMPUTED-TOMOGRAPHY; LEVEL RADIATION-EXPOSURE; IMAGE QUALITY; REPAIR; PERFORMANCE; REDUCTION;
D O I
10.1007/s00330-010-1873-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare in vivo DNA lesions induced during helical and sequential coronary computed tomography angiography (CTA) and to evaluate the effect of CT parameters on double-strand break (DSB) levels. Thirty-six patients were examined with various CT protocols and modes (helical scan, n = 27; sequential scan, n = 9) either using a 64-slice dual-source or a 128-slice CT system. Blood samples were obtained before and 30 min after CT. Lymphocytes were isolated, stained against the phosphorylated histone variant gamma-H2AX, and DSBs were visualised by using fluorescence microscopy. DSB yields 30 min after CTA ranged from 0.04 to 0.71 per cell and showed a significant correlation to DLP (rho = 0.81, p < 0.00001). Median DSB yield and median DLP were significantly lower after sequential compared to helical CT examinations (0.11 vs. 0.37 DSBs/cell and 249 vs. 958 mGy cm, p < 0.00001). Additional calcium scoring led to an increase in DLP (p = 0.15) and DSB levels (p = 0.04). DSB levels normalised to the DLP showed a significant correlation to the attenuation of the blood (rho = 0.53, p = 0.01) and a negative correlation to the body mass index of the patients (rho = -0.37, p = 0.06). gamma-H2AX immunofluorescence microscopy allows one to determine dose-related effects on x-ray-induced DSB levels and to consider individual factors which cannot be monitored by physical dose measurements.
引用
收藏
页码:2917 / 2924
页数:8
相关论文
共 29 条
[1]   Dual-source cardiac computed tomography: image quality and dose considerations [J].
Achenbach, Stephan ;
Anders, Katharina ;
Kalender, Willi A. .
EUROPEAN RADIOLOGY, 2008, 18 (06) :1188-1198
[2]   QUANTIFICATION OF LOW-LEVEL RADIATION EXPOSURE BY CONVENTIONAL CHROMOSOME ABERRATION ANALYSIS [J].
BAUCHINGER, M .
MUTATION RESEARCH-REVIEWS IN GENETIC TOXICOLOGY, 1995, 339 (03) :177-189
[3]   Validation of a Monte Carlo tool for patient-specific dose simulations in multi-slice computed tomography [J].
Deak, Paul ;
van Straten, Marcel ;
Shrimpton, Paul C. ;
Zankl, Maria ;
Kalender, Willi A. .
EUROPEAN RADIOLOGY, 2008, 18 (04) :759-772
[4]   Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: Improved image quality and reduced radiation dose [J].
Earls, James P. ;
Berman, Elise L. ;
Urban, Bruce A. ;
Curry, Charlene A. ;
Lane, Judith L. ;
Jennings, Robert S. ;
McCulloch, Colin C. ;
Hsieh, Jiang ;
Londt, John H. .
RADIOLOGY, 2008, 246 (03) :742-753
[5]   Review of translocations detected by FISH for retrospective biological dosimetry applications [J].
Edwards, AA ;
Lindholm, C ;
Darroudi, F ;
Stephan, G ;
Romm, H ;
Barquincro, J ;
Barrios, L ;
Caballin, MR ;
Roy, L ;
Whitehouse, CA ;
Tawn, EJ ;
Moquet, J ;
Lloyd, DC ;
Voisin, R .
RADIATION PROTECTION DOSIMETRY, 2005, 113 (04) :396-402
[6]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[7]   Contrast Medium-enhanced Radiation Damage Caused by CT Examinations [J].
Grudzenski, Saskia ;
Kuefner, Michael A. ;
Heckmann, Martina B. ;
Uder, Michael ;
Loebrich, Markus .
RADIOLOGY, 2009, 253 (03) :706-714
[8]  
Gutstein Ariel, 2008, J Cardiovasc Comput Tomogr, V2, P311, DOI 10.1016/j.jcct.2008.07.003
[9]   Assessment of Multiple Ordinal Endpoints [J].
Haeberle, Lothar ;
Pfahlberg, Annette ;
Gefeller, Olaf .
BIOMETRICAL JOURNAL, 2009, 51 (01) :217-226
[10]   Radiation dose estimates from cardiac multislice computed tomography in daily practice -: Impact of different scanning protocols on effective dose estimates [J].
Hausleiter, J ;
Meyer, T ;
Hadamitzky, M ;
Huber, E ;
Zankl, M ;
Martinoff, S ;
Kastrati, A ;
Schömig, A .
CIRCULATION, 2006, 113 (10) :1305-1310