Experimental investigation of the response of an amorphous silicon EPID to intensity modulated radiotherapy beams

被引:57
作者
Greer, Peter B. [1 ]
Vial, Philip
Oliver, Lyn
Baldock, Clive
机构
[1] Calvary Mater Newcastle Hosp, Newcastle, NSW, Australia
[2] Univ Newcastle, Newcastle, NSW 2308, Australia
[3] Univ Sydney, Inst Med Phys, Sydney, NSW 2006, Australia
[4] Royal N Shore Hosp, Sydney, NSW, Australia
关键词
amorphous silicon; EPID dosimetry; energy response; intensity modulated;
D O I
10.1118/1.2789406
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this work was to experimentally determine the difference in response of an amorphous silicon (a-Si) electronic portal imaging device (EPID) to the open and multileaf collimator (MLC) transmitted beam components of intensity modulated radiation therapy (IMRT) beams. EPID dose response curves were measured for open and MLC transmitted (MLCtr) 10 X 10 cm(2) beams at central axis and with off axis distance using a shifting field technique. The EPID signal was obtained by replacing the flood-field correction with a pixel sensitivity variation matrix correction. This signal, which includes energy-dependent response, was then compared to ion-chamber measurements. An EPID calibration method to remove the effect of beam energy variations on EPID response was developed for IMRT beams. This method uses the component of open and MLCtr fluence to an EPID pixel calculated from the MLC delivery file and applies separate radially dependent calibration factors for each component. The calibration procedure does not correct for scatter differences between ion chamber in water measurements and EPID response; these must be accounted for separately with a kernel-based approach or similar method. The EPID response at central axis for the open beam was found to be 1.28 +/- 0.03 of the response for the MLCtr beam, with the ratio increasing to 1.39 at 12.5 cm off axis. The EPID response to MLCtr radiation did not change with off-axis distance. Filtering the beam with copper plates to reduce the beam energy difference between open and MLCtr beams was investigated; however, these were not effective at reducing EPID response differences. The change in EPID response for uniform sliding window IMRT beams with MLCtr dose components from 0.3% to 69% was predicted to within 2.3% using the separate EPID response calibration factors for each dose component. A clinical IMRT image calibrated with this method differed by nearly 30% in high MLCtr regions from an image calibrated with an open beam calibration factor only. Accounting for the difference in EPID response to open and MLC,r radiation should improve IMRT dosimetry with a-Si EPIDs. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:4389 / 4398
页数:10
相关论文
共 23 条
[1]   Improving IMRT quality control efficiency using an amorphous silicon electronic portal imager [J].
Budgell, GJ ;
Zhang, Q ;
Trouncer, RJ ;
Mackay, RI .
MEDICAL PHYSICS, 2005, 32 (11) :3267-3278
[2]  
Chang J, 2003, J Appl Clin Med Phys, V4, P287, DOI 10.1120/1.1615071
[3]   Relative dosimetry using active matrix flat-panel imager (AMFPI) technology [J].
El-Mohri, Y ;
Antonuk, LE ;
Yorkston, J ;
Jee, KW ;
Maolinbay, M ;
Lam, KL ;
Siewerdsen, JH .
MEDICAL PHYSICS, 1999, 26 (08) :1530-1541
[4]   Correction of pixel sensitivity variation and off-axis response for amorphous silicon EPID dosimetry [J].
Greer, PB .
MEDICAL PHYSICS, 2005, 32 (12) :3558-3568
[5]   Dosimetric properties of an amorphous silicon electronic portal imaging device for verification of dynamic intensity modulated radiation therapy [J].
Greer, PB ;
Popescu, CC .
MEDICAL PHYSICS, 2003, 30 (07) :1618-1627
[6]   Consequences of the spectral response of an a-Si EPID and implications for dosimetric calibration [J].
Kirkby, C ;
Sloboda, R .
MEDICAL PHYSICS, 2005, 32 (08) :2649-2658
[7]   Investigation of the optimal backscatter for an aSi electronic portal imaging device [J].
Ko, L ;
Kim, JO ;
Siebers, JV .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (09) :1723-1738
[8]   Using fluence separation to account for energy spectra dependence in computing dosimetric a-Si EPID images for IMRT fields [J].
Li, Weidong ;
Siebers, Jeffrey V. ;
Moore, Joseph A. .
MEDICAL PHYSICS, 2006, 33 (12) :4468-4480
[9]   The long-term stability of amorphous silicon flat panel imaging devices for dosimetry purposes [J].
Louwe, RJW ;
McDermott, LN ;
Sonke, JJ ;
Tielenburg, R ;
Wendling, M ;
van Herk, MB ;
Mijnheer, BJ .
MEDICAL PHYSICS, 2004, 31 (11) :2989-2995
[10]   Dosimetric investigation and portal dose image prediction using an amorphous silicon electronic portal imaging device [J].
McCurdy, BMC ;
Luchka, K ;
Pistorius, S .
MEDICAL PHYSICS, 2001, 28 (06) :911-924