Determination of Triton X-100 and Its Critical Micelle Concentration by Using Fluorescent Conjugated Polymer

被引:0
|
作者
Hao Dan [1 ]
Sun Lilin [1 ]
Jin Yingqiong [1 ]
Zhu Changqing [1 ]
机构
[1] Anhui Normal Univ, Anhui Key Lab Chemobiosensing, Coll Chem & Mat Sci, Wuhu 241000, Peoples R China
关键词
fluorescent conjugated polymer; triton X-100; critical micelle concentration (CMC); PERFORMANCE LIQUID-CHROMATOGRAPHY; SURFACTANT COMPLEXATION; WATER; POLYELECTROLYTES; IONS; DYE; DNA;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A novel hydrophobic fluorescent conjugated polymer, i e poly[2,5-bisnonyloxy-1, 4-phenylene-ethynylene-9,10-anthrylene] (PPEA) was synthesized by a Sonogashira palladium-catalyzed cross-coupling reaction of 1,4-diethynyl-2,5-bisnonyloxy-benzene and 9,10-dibromoanthracene And their fluorescence behaviors in aqueous solution containing different surfactants were studied The fluorescence of PPEA was dramatically quenched in aqueous solution However, the fluorescence gradually enhanced with the increasing of the concentration of TX-100 Other surfactants such as CTAB, SDS and Tween had little effect on the fluorescence intensity This phenomenon may be ascribed to the fact that PPEA and TX-100 share the same long aliphatic carbon tail The hydrophobic interaction between PPEA and TX-100 might reduce the conformational disorder of PPEA and induce the PPEA chains to become more extended Also, the effects of the amount of THF, the concentration of PPEA, pH, reaction time and coexisted materials on the determination were investigated Under the optimum conditions, the fluorescence intensity was proportional to the concentration of Triton X-100 in the range of 0 similar to 200 and 200 similar to 700 mu mol/L, respectively And the concentration corresponding to the point of intersection of the two calibration graphs was found to be in good agreement with the critical micelle concentration (CMC) of Triton X-100 Therefore, a fluorescence enhancement method based on fluorescent conjugated polymer has been developed It can be used to selectively detect Triton X-100 in the presence of other surfactants and indicate the CMC of Triton X-100 Two synthetic and three real Triton X-100 samples were determined with satisfactory results
引用
收藏
页码:2215 / 2221
页数:7
相关论文
共 33 条
  • [11] DNA hybridization detection with water-soluble conjugated polymers and chromophore-labeled single-stranded DNA
    Gaylord, BS
    Heeger, AJ
    Bazan, GC
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (04) : 896 - 900
  • [12] GUAN H, 1997, CHIN J PRAC, P24
  • [13] DETERMINATION OF ALKYLPHENOL ETHOXYLATES IN ENVIRONMENTAL-SAMPLES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COUPLED TO FLUORESCENCE DETECTION
    HOLT, MS
    MCKERRELL, EH
    PERRY, J
    WATKINSON, RJ
    [J]. JOURNAL OF CHROMATOGRAPHY, 1986, 362 (03): : 419 - 424
  • [14] Solvation and aggregation of polyphenylethynylene based anionic polyelectrolytes in dilute solutions
    Kaur, Palwinder
    Yue, Hongjun
    Wu, Mingyan
    Liu, Min
    Treece, Jennifer
    Waldeck, David H.
    Xue, Cuihua
    Liu, Haiying
    [J]. JOURNAL OF PHYSICAL CHEMISTRY B, 2007, 111 (29): : 8589 - 8596
  • [15] Sensing of lead ions by a carboxylate-substituted PPE: Multivalency effects
    Kim, IB
    Dunkhorst, A
    Gilbert, J
    Bunz, UHF
    [J]. MACROMOLECULES, 2005, 38 (11) : 4560 - 4562
  • [16] Kimura M, 1998, ADV MATER, V10, P459, DOI 10.1002/(SICI)1521-4095(199804)10:6<459::AID-ADMA459>3.0.CO
  • [17] 2-A
  • [18] KUMARASWAMY, 2004, U S A, V101, P7511
  • [19] Detection of single nucleotide mismatches via fluorescent polymer superquenching
    Kushon, SA
    Bradford, K
    Marin, V
    Suhrada, C
    Armitage, BA
    McBranch, D
    Whitten, D
    [J]. LANGMUIR, 2003, 19 (16) : 6456 - 6464
  • [20] Influence of the Surfactant Chain Length on the Fluorescence Properties of a Water-Soluble Conjugated Polymer
    Laurenti, Marco
    Rubio-Retama, Jorge
    Garcia-Blanco, Francisco
    Lopez-Cabarcos, Enrique
    [J]. LANGMUIR, 2008, 24 (23) : 13321 - 13327