Preparation and evaluation of hydrophobically associating polyacrylamide coated silica composite as high performance liquid chromatographic stationary phase

被引:18
作者
Si, Tiantian [1 ,2 ,3 ]
Song, Xiao [4 ]
Wang, Licheng [1 ,2 ]
Guo, Yong [1 ,2 ]
Liang, Xiaojing [1 ,2 ]
Wang, Shuai [1 ,2 ]
机构
[1] Chinese Acad Sci, Lanzhou Inst Chem Phys, CAS Key Lab Chem Northwestern Plant Resources, Lanzhou 730000, Gansu, Peoples R China
[2] Chinese Acad Sci, Lanzhou Inst Chem Phys, Key Lab Nat Med Gansu Prov, Lanzhou 730000, Gansu, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Xinjiang Oilfied Co Petrochina, Engn Technol Res Inst, Karamay 834000, Peoples R China
基金
美国国家科学基金会;
关键词
Hydrophilic interaction liquid chromatography; Hydrophilic polymer; Hydrophobically associating polyacrylamide; Stationary phase; HYDROPHILIC INTERACTION CHROMATOGRAPHY; SEPARATION; RETENTION; COLUMNS; MODEL; ACID;
D O I
10.1016/j.microc.2019.104330
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A hydrophobically associating polyacrylamide (HAPM)-coated silica packing (HAPM@silica) as a novel stationary phase was synthesized by a simple thermal immobilization to separate multiple polar compounds for the first time. The successful immobilization of HAPM on the silica support was confirmed by elemental analysis, scanning electron microscopy (SEM) and the Brunauer-Emmett-Teller (BET). The thickness of HAPM coating is crucial and the one-layer HAPM@silica stationary phase was demonstrated the highest separation efficiency. Compared with the bare silica and amino modified silica, the new stationary phase showed better separation performance for multiple polar compounds such as bases, alkaloids, carbohydrates and amino acid compounds under the experimental conditions. The chromatographic behaviors were evaluated by investigating the effects of acetonitrile content, water content, mobile phase pt-1 on separation. A typical hydrophilic interaction liquid chromatography (HILIC) retention feature of HAPM based column was observed at the low percentage of water content. The packing material also showed excellent chromatographic repeatability with intraday RSDs of the retention time of five bases less than 0.46% (n = 10) and interday RSDs less than 1.45% (n - 5). In summary, the new chromatographic material can be used for a feasible option for analysis of polar compounds.
引用
收藏
页数:5
相关论文
共 38 条
  • [1] Zwitterionic Poly(amino acid methacrylate) Brushes
    Alswieleh, Abdullah M.
    Cheng, Nan
    Canton, Irene
    Ustbas, Burcin
    Xue, Xuan
    Ladmiral, Vincent
    Xia, Sijing
    Ducker, Robert E.
    El Zubir, Osama
    Cartron, Michael L.
    Hunter, C. Neil
    Leggett, Graham J.
    Armes, Steven P.
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2014, 136 (26) : 9404 - 9413
  • [2] [Anonymous], [No title captured]
  • [3] Hydrophilic interaction chromatography/electrospray mass spectrometry analysis of carbohydrate-related metabolites from Arabidopsis thaliana leaf tissue
    Antonio, Carla
    Larson, Tony
    Gilday, Alison
    Graham, Ian
    Bergstroem, Ed
    Thomas-Oates, Jane
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (09) : 1399 - 1407
  • [4] Polyethyleneimine-functionalized carbon dots and their precursor co-immobilized on silica for hydrophilic interaction chromatography
    Cai, Tianpei
    Zhang, Haijuan
    Chen, Jia
    Li, Zhan
    Qiu, Hongdeng
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2019, 1597 : 142 - 148
  • [5] Fifty years of alkaloid biosynthesis in Phytochemistry
    Cordell, Geoffrey A.
    [J]. PHYTOCHEMISTRY, 2013, 91 : 29 - 51
  • [6] Hydrophilic interaction chromatography for mass spectrometric metabonomic studies of urine
    Cubbon, Simon
    Bradbury, Timothy
    Wilson, Julie
    Thomas-Oates, Jane
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (23) : 8911 - 8918
  • [7] Stationary phases based on poly(methyloctadecylsiloxane) thermally immobilized onto titanized silica for high-performance liquid chromatography
    da Silva, Carla G. A.
    Collins, Carol H.
    [J]. MICROCHEMICAL JOURNAL, 2013, 109 : 150 - 157
  • [8] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC COMPUTER-SIMULATION BASED ON A RESTRICTED MULTIPARAMETER APPROACH .1. THEORY AND VERIFICATION
    DOLAN, JW
    LOMMEN, DC
    SNYDER, LR
    [J]. JOURNAL OF CHROMATOGRAPHY, 1990, 535 (1-2): : 55 - 74
  • [9] Elucidation of carotenoid patterns in citrus products by means of comprehensive normal-phase x reversed-phase liquid chromatography
    Dugo, Paola
    Skerikova, Veronika
    Kumm, Tiina
    Trozzi, Alessandra
    Jandera, Pavel
    Mondello, Luigi
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (22) : 7743 - 7750
  • [10] Orthogonal separation on one beta-cyclodextrin column by switching reversed-phase liquid chromatography and hydrophilic interaction chromatography
    Feng, Jia-tao
    Guo, Zhi-mou
    Shi, Hui
    Gu, Jiang-ping
    Jin, Yu
    Liang, Xin-miao
    [J]. TALANTA, 2010, 81 (4-5) : 1870 - 1876