3T MRI of the knee with optimised isotropic 3D sequences: Accurate delineation of intra-articular pathology without prolonged acquisition times

被引:14
作者
Abdulaal, Osamah M. [1 ]
Rainford, Louise [1 ]
MacMahon, Peter [2 ,4 ]
Kavanagh, Eoin [2 ,4 ]
Galligan, Marie [1 ]
Cashman, James [3 ,4 ]
McGee, Allison [1 ]
机构
[1] Univ Coll Dublin, Sch Med, Radiog & Diagnost Imaging, Dublin 4, Ireland
[2] Mater Misericordiae Univ Hosp, Dept Radiol, Dublin, Ireland
[3] Mater Misericordiae Univ Hosp, Dept Orthopaed, Dublin, Ireland
[4] Univ Coll Dublin, Sch Med, Dublin, Ireland
关键词
Magnetic resonance imaging; Knee joint; Cartilage; Articular; Evidence-based practice; FAST SPIN-ECHO; ARTICULAR-CARTILAGE; IMAGING TECHNIQUES; TRUE FISP; STANDARD;
D O I
10.1007/s00330-017-4816-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To investigate optimised isotropic 3D turbo spin echo (TSE) and gradient echo (GRE)-based pulse sequences for visualisation of articular cartilage lesions within the knee joint. Methods Optimisation of experimental imaging sequences was completed using healthy volunteers (n=16) with a 3-Tesla (3T) MRI scanner. Imaging of patients with knee cartilage abnormalities (n=57) was then performed. Acquired sequences included 3D proton density-weighted (PDW) TSE (SPACE) with and without fat-suppression (FS), and T2*W GRE (TrueFISP) sequences, with acquisition times of 6: 51, 6:32 and 5:35 min, respectively. Results One hundred sixty-one confirmed cartilage lesions were detected and categorised (Grade II n=90, Grade III n=71). The highest sensitivity and specificity for detecting cartilage lesions were obtained with TrueFISP with values of 84.7% and 92%, respectively. Cartilage SNR mean for PDW SPACE-FS was the highest at 72.2. TrueFISP attained the highest CNR means for joint fluid/cartilage (101.5) and joint fluid/ligament (156.5), and the lowest CNR for cartilage/meniscus (48.5). Significant differences were identified across the three sequences for all anatomical structures with respect to SNR and CNR findings (p-value <0.05). Conclusion Isotropic TrueFISP at 3T, optimised for acquisition time, accurately detects cartilage defects, although it demonstrated the lowest contrast between cartilage and meniscus.
引用
收藏
页码:4563 / 4570
页数:8
相关论文
共 27 条
[1]   An update on risk factors for cartilage loss in knee osteoarthritis assessed using MRI-based semiquantitative grading methods [J].
Alizai, Hamza ;
Roemer, Frank W. ;
Hayashi, Daichi ;
Crema, Michel D. ;
Felson, David T. ;
Guermazi, Ali .
EUROPEAN RADIOLOGY, 2015, 25 (03) :883-893
[2]   Ambient lighting: Effect of illumination on soft-copy viewing of radiographs of the wrist [J].
Brennan, Patrick C. ;
McEntee, Mark ;
Evanoff, Michael ;
Phillips, Peter ;
O'Connor, William T. ;
Manning, David J. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (02) :W177-W180
[3]   Multiecho IDEAL Gradient-Echo Water-Fat Separation for Rapid Assessment of Cartilage Volume at 1.5 T: Initial Experience [J].
Chen, Christina A. ;
Lu, Wenmiao ;
John, Chand T. ;
Hargreaves, Brian A. ;
Reeder, Scott B. ;
Delp, Scott L. ;
Siston, Robert A. ;
Gold, Garry E. .
RADIOLOGY, 2009, 252 (02) :561-567
[4]   Three-dimensional turbo spin-echo magnetic resonance imaging (MRI) and semiquantitative assessment of knee osteoarthritis: comparison with two-dimensional routine MRI [J].
Crema, M. D. ;
Nogueira-Barbosa, M. H. ;
Roemer, F. W. ;
Marra, M. D. ;
Niu, J. ;
Chagas-Neto, F. A. ;
Gregio-Junior, E. ;
Guermazi, A. .
OSTEOARTHRITIS AND CARTILAGE, 2013, 21 (03) :428-433
[5]   Articular Cartilage in the Knee: Current MR Imaging Techniques and Applications in Clinical Practice and Research [J].
Crema, Michel D. ;
Roemer, Frank W. ;
Marra, Monica D. ;
Burstein, Deborah ;
Gold, Garry E. ;
Eckstein, Felix ;
Baum, Thomas ;
Mosher, Timothy J. ;
Carrino, John A. ;
Guermazi, Ali .
RADIOGRAPHICS, 2011, 31 (01) :37-U76
[6]   IVIM diffusion-weighted imaging of the liver at 3.0 T: Comparison with 1.5 T [J].
Cui, Yong ;
Dyvorne, Hadrien ;
Besa, Cecilia ;
Cooper, Nancy ;
Taouli, Bachir .
EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2015, 2 :123-128
[7]   Internal knee derangement assessed with 3-minute three-dimensional isovoxel true FISP MR sequence: Preliminary study [J].
Duc, Sylvain R. ;
Pfirrmann, Christian W. A. ;
Koch, Peter P. ;
Zanetti, Marco ;
Hodler, Juerg .
RADIOLOGY, 2008, 246 (02) :526-535
[8]   Articular cartilage defects detected with 3D water-excitation true FISP: Prospective comparison with sequences commonly used for knee imaging [J].
Duc, Sylvain R. ;
Pfirrmann, Christian W. A. ;
Schmid, Marius R. ;
Zanetti, Marco ;
Koch, Peter P. ;
Kalberer, Fabian ;
Hodler, Juerg .
RADIOLOGY, 2007, 245 (01) :216-223
[9]   High-resolution cartilage imaging of the knee at 3 T: Basic evaluation of modern isotropic 3D MR-sequences [J].
Friedrich, Klaus M. ;
Reiter, Gert ;
Kaiser, Bernd ;
Mayerhoefer, Marius ;
Deimling, Michael ;
Jellus, Vladimir ;
Horger, Wilhelm ;
Trattnig, Siegfried ;
Schweitzer, Mark ;
Salomonowitz, Erich .
EUROPEAN JOURNAL OF RADIOLOGY, 2011, 78 (03) :398-405
[10]   Prediction of medial tibiofemoral compartment joint space loss progression using volumetric cartilage measurements: Data from the FNIH OA biomarkers consortium [J].
Hafezi-Nejad, Nima ;
Guermazi, Ali ;
Roemer, Frank W. ;
Hunter, David J. ;
Dam, Erik B. ;
Zikria, Bashir ;
Kwoh, C. Kent ;
Demehri, Shadpour .
EUROPEAN RADIOLOGY, 2017, 27 (02) :464-473