Pulsatile Lavage During Cementation of Total Knee Arthroplasty - Is Fixation Impaired? A Cadaver Study

被引:1
作者
Glowalla, Claudio [1 ,2 ]
Ertl, Max [1 ]
Lenze, Ulrich [1 ]
Lazic, Igor [1 ]
Burgkart, Rainer [1 ]
Lang, Jan J. [1 ,3 ]
Von Eisenhart-Rothe, Rudiger [1 ]
Pohlig, Florian [1 ]
机构
[1] Tech Univ Munich, Dept Orthopaed Surg, Klinikum Rechts Isar, Munich, Germany
[2] BG Unfallklin Murnau, Murnau, Germany
[3] Tech Univ Munich, Dept Mech Engn, Chair Nondestruct Testing, Munich, Germany
来源
IN VIVO | 2022年 / 36卷 / 02期
关键词
Bone cement; pulsatile lavage; total knee arthroplasty; TKA; PMMA; polymerization; GUN PRESSURIZATION; BONE; MANTLE;
D O I
10.21873/invivo.12752
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background/Aim: Increasing economic pressure in modern healthcare necessitates an increase in efficiency in total knee arthroplasty (TKA) while maintaining high-quality outcomes. Removal of debris using pulsatile lavage (PL) during cement polymerization may considerably reduce the operative duration. However, water can penetrate the interface, resulting in impaired implant fixation. The aim of the present study was to investigate the impact of early-onset PL during bone cement polymerization on implant fixation and operative duration. Materials and Methods: Cemented implantation of tibial trays was performed in 20 fresh-frozen human tibiae from 10 donors in a matched-pair study design in two groups: 1) PL during cement polymerization; and 2) PL after completion of the polymerization process. The cement penetration depth was analysed by computed tomography (CT), and the pull-out force was measured to evaluate primary implant fixation. The duration of the procedure was recorded for both groups. Results: Comparable pull-out forces were observed in the experimental (2,213 N) and control groups (2,350 N; p=0.68). The mean depth of cement penetration was similar in both groups. PL during cement polymerization could decrease the operative duration by 10 min. Conclusion: The application of PL during cement polymerization could significantly reduce operative duration and had no adverse effect on the mechanical fixation of the tibial component.
引用
收藏
页码:672 / 677
页数:6
相关论文
共 21 条
[1]  
Australian Orthopaedic Association National Joint Replacement Registry, 2018, Hip, knee and shoulder arthroplasty: 2018 annual report
[2]  
Bert JM, 1998, CLIN ORTHOP RELAT R, P73
[3]   Current Epidemiology of Revision Total Knee Arthroplasty in the United States [J].
Delanois, Ronald E. ;
Mistry, Jaydev B. ;
Gwam, Chukwuweike U. ;
Mohamed, Nequesha S. ;
Choksi, Ujval S. ;
Mont, Michael A. .
JOURNAL OF ARTHROPLASTY, 2017, 32 (09) :2663-2668
[4]   Intraoperative bacterial contamination in total hip and knee arthroplasty is associated with operative duration and peeling of the iodine-containing drape from skin [J].
Hanada, Mitsuru ;
Hotta, Kensuke ;
Furuhashi, Hiroki ;
Matsuyama, Yukihiro .
EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (05) :917-921
[5]   STUDIES OF THE MECHANISM BY WHICH THE MECHANICAL FAILURE OF POLYMETHYLMETHACRYLATE LEADS TO BONE-RESORPTION [J].
HOROWITZ, SM ;
DOTY, SB ;
LANE, JM ;
BURSTEIN, AH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (06) :802-813
[6]   An experimental comparison of different devices for pulsatile high-pressure lavage and their relevance to cement intrusion into cancellous bone [J].
Kalteis, Thomas ;
Pfoerringer, Dominik ;
Herold, Thomas ;
Handel, Martin ;
Renkawitz, Tobias ;
Plitz, Wolfgang .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2007, 127 (10) :873-877
[7]  
Kopec M, 2009, CAN J SURG, V52, P490
[8]   The Effect of Cement Gun and Cement Syringe Use on the Tibial Cement Mantle in Total Knee Arthroplasty [J].
Lutz, Michael J. ;
Pincus, Paul F. ;
Whitehouse, Sarah L. ;
Halliday, Brett R. .
JOURNAL OF ARTHROPLASTY, 2009, 24 (03) :461-467
[9]   Survey of current cementing techniques in total knee replacement [J].
Lutz, MJ ;
Halliday, BR .
ANZ JOURNAL OF SURGERY, 2002, 72 (06) :437-439
[10]   Results of Cemented vs Cementless Primary Total Knee Arthroplasty Using the Same Implant Design [J].
Miller, Adam J. ;
Stimac, Jeffrey D. ;
Smith, Langan S. ;
Feher, Anthony W. ;
Yakkanti, Madhusudhan R. ;
Malkani, Arthur L. .
JOURNAL OF ARTHROPLASTY, 2018, 33 (04) :1089-1093