Enhanced Biosensing Activity of Bimetallic Surface Plasmon Resonance Sensor

被引:34
|
作者
Kashyap, Ritayan [1 ]
Chakraborty, Soumik [1 ]
Zeng, Shuwen [2 ]
Swarnakar, Sikha [1 ]
Kaur, Simran [3 ]
Doley, Robin [3 ]
Mondal, Biplob [1 ]
机构
[1] Tezpur Univ, Dept Elect & Commun Engn, Tezpur 784028, Assam, India
[2] Univ Limoges, CNRS, XLIM Res Inst, UMR 7252, 123 Ave Albert Thomas, F-87060 Limoges, France
[3] Tezpur Univ, Dept Mol Biol & Biotechnol, Tezpur 784028, Assam, India
基金
欧盟地平线“2020”;
关键词
full width at half maximum (FWHM); monoclonal anti-IgG; pulsed DC magnetron; sensitivity; surface plasmon resonance; IMMOBILIZATION STRATEGIES; ANTIBODY INTERACTION; GOLD NANOPARTICLES; FIELD ENHANCEMENT; GAS-DETECTION; SENSITIVITY; SILVER; FILM;
D O I
10.3390/photonics6040108
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Surface plasmon resonance (SPR) sensors present a challenge when high sensitivity and small FWHM (full width at half maximum) are required to be achieved simultaneously. FWHM is defined by the difference between the two extreme values of the independent variable at which the value of the dependent variable is equal to half of its maximum. A smaller value of FWHM indicates better accuracy of SPR measurements. Theoretically, many authors have claimed the possibility of simultaneously achieving high sensitivity and small FWHM, which in most of the cases has been limited by experimental validation. In this report, an experimental study on the improved surface plasmon resonance (SPR) characteristics of gold over silver bimetallic sensor chips of different film thicknesses is presented. A comparative study of antigen-antibody interaction of the bimetallic chip using a custom-made, low-cost, and portable SPR device based on an angular interrogation scheme of Kretschmann configuration is performed. Pulsed direct current (DC) magnetron-sputtered bimetallic films of gold over silver were used in the construction of the SPR chip. The FWHM and sensitivity of the bimetallic sensors were firstly characterized using standard solutions of known refractive index which were later immobilized with monoclonal anti-immunoglobulin G (IgG) in the construction of the SPR biochip. Spectroscopic measurements such as ultraviolet-visible light spectroscopy (UV-Vis) and Fourier-transform infrared spectroscopy (FTIR) were used for the confirmation of the immobilization of the antibody. The performance of the bimetallic SPR biochip was investigated by exposing the sensor to various concentrations of the target protein. The results indicated that the bimetallic sensors of silver/gold had a 3.5-fold reduced FWHM compared to pure gold-based sensors, indicating a higher detection accuracy. In addition, they exhibited a significant shift in resonance angle as high as 8.5 +/- 0.2 due to antigen-antibody interaction, which was similar to 1.42-fold higher than observed for pure silver-based sensors.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Surface plasmon resonance polarizator for biosensing and imaging
    Patskovsky, S.
    Meunier, M.
    Kabashin, A. V.
    OPTICS COMMUNICATIONS, 2008, 281 (21) : 5492 - 5496
  • [32] On the sensitivity and signal to noise ratio of a step-index fiber optic surface plasmon resonance sensor with bimetallic layers
    Sharma, AK
    Gupta, BD
    OPTICS COMMUNICATIONS, 2005, 245 (1-6) : 159 - 169
  • [33] Highly Stable Silver Nanoplates for Surface Plasmon Resonance Biosensing
    Gao, Chuanbo
    Lu, Zhenda
    Liu, Ying
    Zhang, Qiao
    Chi, Miaofang
    Cheng, Quan
    Yin, Yadong
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2012, 51 (23) : 5629 - 5633
  • [34] Parametric study on the bimetallic cladding silica waveguide surface plasmon resonance sensor
    Shuqing Yang
    Lanting Ji
    Shanshan Zhao
    Juan Su
    Chi Wu
    Optical and Quantum Electronics, 2023, 55
  • [35] Parametric study on the bimetallic cladding silica waveguide surface plasmon resonance sensor
    Yang, Shuqing
    Ji, Lanting
    Zhao, Shanshan
    Su, Juan
    Wu, Chi
    OPTICAL AND QUANTUM ELECTRONICS, 2023, 55 (08)
  • [36] Bimetallic silver-gold film waveguide surface plasmon resonance sensor
    Ong, Biow Hiem
    Yuan, Xiaocong
    Tjin, Swee Chuan
    INTEGRATED OPTICS: DEVICES, MATERIALS, AND TECHNOLOGIES X, 2006, 6123
  • [37] Enhanced performance of SnSe-Graphene hybrid photonic surface plasmon refractive sensor for biosensing applications
    Rahman, M. Saifur
    Rikta, K. A.
    Abdulrazak, Lway Faisal
    Anower, M. S.
    PHOTONICS AND NANOSTRUCTURES-FUNDAMENTALS AND APPLICATIONS, 2020, 39
  • [38] Enhanced Photonic Spin Hall Effect with a Bimetallic Film Surface Plasmon Resonance
    Xing Jiang
    Qingkai Wang
    Jun Guo
    Shuqing Chen
    Xiaoyu Dai
    Yuanjiang Xiang
    Plasmonics, 2018, 13 : 1467 - 1473
  • [39] Enhanced Photonic Spin Hall Effect with a Bimetallic Film Surface Plasmon Resonance
    Jiang, Xing
    Wang, Qingkai
    Guo, Jun
    Chen, Shuqing
    Dai, Xiaoyu
    Xiang, Yuanjiang
    PLASMONICS, 2018, 13 (04) : 1467 - 1473
  • [40] Bimetallic layers increase sensitivity of affinity sensors based on surface plasmon resonance
    Zynio, SA
    Samoylov, AV
    Surovtseva, ER
    Mirsky, VM
    Shirshov, YM
    SENSORS, 2002, 2 (02) : 62 - 70