Comparison of two instruments measuring carotid-femoral pulse wave velocity: Vicorder versus SphygmoCor

被引:39
作者
van Leeuwen-Segarceanu, Elena M. [1 ]
Tromp, Wilma F. [2 ]
Bos, Willem-Jan W. [1 ]
Vogels, Oscar J. M. [4 ]
Groothoff, Jaap W. [2 ]
van der Lee, Johanna H. [3 ]
机构
[1] St Antonius Hosp, Dept Internal Med, NL-3435 CM Nieuwegein, Netherlands
[2] AMC Amsterdam, Dept Pediat Nephrol, Emma Childrens Hosp, Amsterdam, Netherlands
[3] AMC Amsterdam, Dept Pediat Clin Epidemiol, Amsterdam, Netherlands
[4] St Antonius Hosp Nieuwegein, Dept Neurol & Neurophysiol, Nieuwegein, Netherlands
关键词
carotid-femoral pulse wave velocity; reproducibility of results; SphygmoCor; Vicorder; STAGE RENAL-DISEASE; ARTERIAL STIFFNESS; REPRODUCIBILITY; REFLECTION; MORTALITY; INDEX;
D O I
10.1097/HJH.0b013e32833a8b83
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background The carotid-femoral pulse wave velocity (PWVcf) is used as an indicator of arterial stiffness. It is often measured using applanation tonometry, for instance with the SphygmoCor. In young children, this method is difficult to perform. Therefore, techniques are needed that are less dependent on patient compliance. The Vicorder device uses the oscillometric technique to measure the PWVcf and is thought to be less time consuming and less dependent on operator skills. Objective To compare the PWVcf measured by an extensively used device (SphygmoCor) and the Vicorder in adults initially. Methods Thirty-eight healthy volunteers (20 men, mean age 48 +/- 13.1 years) participated in this cross-sectional study. The PWVcf was assessed twice using the SphygmoCor and the Vicorder by a single investigator during one visit. Intra-rater reproducibility of each instrument and comparison between the two instruments were assessed by the Bland-Altman method. Results The mean difference (95% confidence interval) between repeated measurements was 0.09 (-0.20 to 0.38) m/s and 0.24 (-0.55 to 1.03) m/s, for the SphygmoCor and Vicorder, respectively. The Limits of Agreement (LoA) were -1.53 to 1.71 m/s and -4.24 to 4.72 m/s, for the SphygmoCor and Vicorder, respectively. The mean PWVcf measured by the Vicorder was 0.58 (-0.20 to 1.35) m/s higher than the PWVcf measured by the SphygmoCor. The LoA between the two instruments were -3.50 to 4.66 m/s. Conclusion The LoA of both instruments exceed a value of 1.5 m/s. The LoA of the Vicorder PWVcf measurements are considered too wide for using this technique reliably in adults or in children. J Hypertens 28: 1687-1691 (c) 2010 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:1687 / 1691
页数:5
相关论文
共 16 条
  • [1] ASSESSMENT OF ARTERIAL DISTENSIBILITY BY AUTOMATIC PULSE-WAVE VELOCITY-MEASUREMENT - VALIDATION AND CLINICAL-APPLICATION STUDIES
    ASMAR, R
    BENETOS, A
    TOPOUCHIAN, J
    LAURENT, P
    PANNIER, B
    BRISAC, AM
    TARGET, R
    LEVY, BI
    [J]. HYPERTENSION, 1995, 26 (03) : 485 - 490
  • [2] A new oscillometric method for assessment of arterial stiffness:: comparison with tonometric and piezo-electronic methods
    Baulmann, Johannes
    Schillings, Ulrich
    Rickert, Susanna
    Uen, Sakir
    Duesing, Rainer
    Illyes, Miklos
    Cziraki, Attila
    Nickering, Georg
    Mengden, Thomas
    [J]. JOURNAL OF HYPERTENSION, 2008, 26 (03) : 523 - 528
  • [3] Impact of aortic stiffness on survival in end-stage renal disease
    Blacher, J
    Guerin, AP
    Pannier, B
    Marchais, SJ
    Safar, ME
    London, GM
    [J]. CIRCULATION, 1999, 99 (18) : 2434 - 2439
  • [4] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [5] Aortic pulse-wave velocity and its relationship to mortality in diabetes and glucose intolerance - An integrated index of vascular function?
    Cruickshank, K
    Riste, L
    Anderson, SG
    Wright, JS
    Dunn, G
    Gosling, RG
    [J]. CIRCULATION, 2002, 106 (16) : 2085 - 2090
  • [6] Reproducibility of pulse-wave analysis and pulse-wave velocity determination in chronic kidney disease
    Frimodt-Moller, Marie
    Nielsen, Arne Hoj
    Kamper, Anne-Lise
    Strandgaard, Svend
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2008, 23 (02) : 594 - 600
  • [7] Simultaneous Measurement of Beat-to-Beat Carotid Diameter and Pressure Changes to Assess Arterial Mechanical Properties
    Giannattasio, Cristina
    Salvi, Paolo
    Valbusa, Filippo
    Kearney-Schwartz, Anna
    Capra, Anna
    Amigoni, Maria
    Failla, Monica
    Boffi, Lucia
    Madotto, Fabiana
    Benetos, Athanasios
    Mancia, Giuseppe
    [J]. HYPERTENSION, 2008, 52 (05) : 896 - 902
  • [8] Mortality and causes of death of end-stage renal disease in children: A Dutch cohort study
    Groothoff, JW
    Gruppen, MP
    Offringa, M
    Hutten, J
    Lilien, MR
    van de Kar, NJ
    Wolff, ED
    Davin, JC
    Heymans, HSA
    [J]. KIDNEY INTERNATIONAL, 2002, 61 (02) : 621 - 629
  • [9] Expert consensus document on arterial stiffness: methodological issues and clinical applications
    Laurent, Stephane
    Cockcroft, John
    Van Bortel, Luc
    Boutouyrie, Pierre
    Giannattasio, Cristina
    Hayoz, Daniel
    Pannier, Bruno
    Vlachopoulos, Charalambos
    Wilkinson, Ian
    Struijker-Boudier, Harry
    [J]. EUROPEAN HEART JOURNAL, 2006, 27 (21) : 2588 - 2605
  • [10] Relation between number of cardiovascular risk factors/events and noninvasive Doppler ultrasound assessments of aortic compliance
    Lehmann, ED
    Hopkins, KD
    Rawesh, A
    Joseph, RC
    Kongola, K
    Coppack, SW
    Gosling, RG
    [J]. HYPERTENSION, 1998, 32 (03) : 565 - 569