Graphene-Based Highly Sensitive Refractive Index Biosensors Using C-Shaped Metasurface

被引:44
|
作者
Patel, Shobhit K. [1 ,2 ]
Parmar, Juveriya [1 ,2 ]
Kosta, Yogeshwar P. [1 ,2 ]
Charola, Shreyas [2 ]
Zakaria, Rozalina Binti [3 ]
Truong Khang Nguyen [4 ,5 ]
Dhasarathan, Vigneswaran [4 ,5 ]
机构
[1] Marwadi Univ, Dept Phys, Rajkot 360003, Gujarat, India
[2] Marwadi Univ, Dept ECE, Rajkot 360003, Gujarat, India
[3] Univ Malaya, Photon Res Ctr, Kuala Lumpur 50603, Malaysia
[4] Ton Duc Thang Univ, Inst Computat Sci, Div Computat Phys, Ho Chi Minh City 700000, Vietnam
[5] Ton Duc Thang Univ, Fac Elect & Elect Engn, Ho Chi Minh City 700000, Vietnam
关键词
Biosensors; Graphene; Absorption; Sensitivity; Molecular biophysics; Reflectivity; Sensor; graphene; metasurface; peak wavelength and sensitivity; ELECTROMAGNETICALLY INDUCED TRANSPARENCY; METAMATERIAL; OXIDE; SENSOR; ANALOG; DNA;
D O I
10.1109/JSEN.2020.2976571
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this work, graphene-based metasurface infrared biosensors are presented. The C-shaped tungsten metasurface is placed over graphene material to achieve higher sensitivity. The sensitivity of biosensors depends on how the absorption peak is shifted by the addition of biomolecules over the sensor. The wavelength shift of 900nm is achieved for the proposed biosensors with haemoglobin biomolecules. The sensitivity of 2571 nm/RIU is achieved by using this graphene-based metasurface design. The sensitivity of hemoglobin biomolecules with urine biomolecules is also investigated and it is 3846nm/RIU. The sensitivity of the proposed biosensors is varied by changing the design parameters such as C-shaped tungsten metasurface thickness, C-shaped tungsten metasurface width, SiO2 layer thickness, and tungsten bottom layer thickness. The proposed biosensors design is also compared with other published researches and showing better sensitivity than these published researches. The optimized physical parameters are achieved in this paper. The proposed highly sensitive biosensors is having great potential to become a building block for medical biosensing devices and photovoltaic devices.
引用
收藏
页码:6359 / 6366
页数:8
相关论文
共 50 条
  • [31] Plasmon induced transparency and refractive index sensing in a new type of graphene-based plasmonic waveguide
    Wu, Di
    Tian, Jinping
    Li, Lu
    Yang, Rongcao
    OPTICS COMMUNICATIONS, 2018, 412 : 41 - 48
  • [32] Highly sensitive refractive index sensor based on a D-shaped few-mode fiber with silver and graphene film
    Bai, Ge
    Li, Shuguang
    Fan, Xiaoya
    Meng, Xiaojian
    Wang, Yujun
    Gao, Zhigang
    OPTIK, 2022, 267
  • [33] Terahertz imaging using C-shaped metallic metasurface-based optics
    Ivaskeviciute-Povilauskiene, R.
    Cizas, V.
    Nacius, E.
    Grigelionis, I.
    Redeckas, K.
    Stanaitis, K.
    Orlov, S.
    Valusis, G.
    Minkevicius, L.
    TERAHERTZ PHOTONICS III, 2024, 12994
  • [34] A tunable graphene-based phase-jump inversion plasmonic sensor for ultra-sensitive refractive index sensing over THz frequency
    Li, Xing-Yue
    Zhang, Tian-Yao
    Zhang, Zhao-Hui
    Zhao, Xiao-Yan
    Zhang, Zhuo-Ya
    Tao, Lu-Qi
    Huang, Zheng-yong
    Yan, Jian-Feng
    Sun, Pu
    Zhao, Xuan
    Wu, Xian-hao
    Yuan, Yuan
    Cao, Can
    SENSORS AND ACTUATORS A-PHYSICAL, 2024, 365
  • [35] Graphene-based tunable quad-band fan-shaped split-ring metamaterial absorber and refractive index sensor for THz spectrum
    Nickpay, Mohammad-Reza
    Danaie, Mohammad
    Shahzadi, Ali
    MICRO AND NANOSTRUCTURES, 2023, 173
  • [36] Graphene-based H-shaped biosensor with high sensitivity and optimization using ML-based algorithm
    Patel, Shobhit K.
    Surve, Jaymit
    Parmar, Juveriya
    Armghan, Ammar
    Aliqab, Khaled
    Altahan, Baraa Riyadh
    Ahmed, Kawsar
    Bui, Francis M.
    Al-Zahrani, Fahad Ahmed
    ALEXANDRIA ENGINEERING JOURNAL, 2023, 68 : 15 - 28
  • [37] Highly sensitive optical biosensor based on electromagnetically induced transparency in a graphene-dielectric metasurface
    Mohsen Bagheritabar
    Mahdi Molaei Zarasvand
    Afsoon Yazdani
    Melika Molaei Zarasvand
    Mohammad Salemizadeh Parizi
    Shahram Bahadori-Haghighi
    Optical and Quantum Electronics, 57 (4)
  • [38] Numerical analysis of a highly sensitive SOI MRR refractive index sensor with performance enhancement using graphene and gold
    Intisar, Tasin
    Alam, Ahmed Shadman
    Hoque, Ishtiaqul
    Faruque, Md Omar
    HELIYON, 2024, 10 (04)
  • [39] A Highly Sensitive Graphene-based Field Effect Transistor for the Detection of Myoglobin
    Krsihna, B. Vamsi
    Gangadhar, A.
    Ravi, S.
    Mohan, D.
    Panigrahy, Asisa Kumar
    Rajeswari, V. Raja
    Prakash, M. Durga
    SILICON, 2022, 14 (17) : 11741 - 11748
  • [40] A Highly Sensitive Plasmonic Graphene-Based Structure for Deoxyribonucleic Acid Detection
    Salehnezhad, Zohre
    Soroosh, Mohammad
    Mondal, Haraprasad
    PHOTONICS, 2024, 11 (06)