Gadolinium Enhances Dual-energy Computed Tomography Scan of Pulmonary Artery

被引:1
|
作者
Xie, An [1 ]
Sun, Wen-Jie [1 ]
Zeng, Yan-Feng [2 ]
Liu, Peng [1 ]
Liu, Jian-Bin [1 ]
Huang, Feng [1 ]
机构
[1] Hunan Normal Univ, Hunan Prov Peoples Hosp, Dept Radiol, Affiliated Hosp 1, Changsha 410005, Peoples R China
[2] Hunan Chest Hosp, Dept Radiol, Changsha 410013, Peoples R China
关键词
gadopentetate dimeglumine; computed tomography pulmonary angiography; dual-energy scan; turbo flash scan; virtual monoenergetic imaging; TO-NOISE RATIO; CONTRAST-MEDIA; CT ANGIOGRAPHY; GADOPENTETATE DIMEGLUMINE; ADVERSE-REACTIONS; IMAGE QUALITY; DEPOSITION; SAFETY; AGENT; BRAIN;
D O I
10.1007/s11596-022-2621-5
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: To evaluate the feasibility of using gadopentetate dimeglumine (Gd-DTPA) for dual-energy computed tomography pulmonary angiography (CTPA). Methods: Sixty-six patients were randomly divided into three groups and underwent CTPA. Group A had a turbo flash scan using an iohexol injection, Group B had a turbo flash scan using Gd-DTPA, and Group C had a dual-energy scan using Gd-DTPA. The original images of Group C were linearly blended with a blending factor of 0.5 or reconstructed at 40, 50, 60, 70, 80, 90, 100, and 110 keV, respectively. The groups were compared in terms of pulmonary artery CT value, image quality, and radiation dose. Results: The pulmonary artery CT values were significantly higher in Group C-40 keV than in Groups B and C, but lower than in Group A. There was no significant difference in the image noise of Groups C-40 keV, B, and C. Moreover, Group A had the largest beam hardening artifacts of the superior vena cava (SVC), followed by Groups B and C. Group C-40 keV showed better vascular branching than the other three groups, among which Group B was superior to Group A. The subjective score of the image quality of Groups A, B, and C showed no significant difference, but the score was significantly higher in Group C-40 keV than in Groups A and B. The radiation dose was significantly lower in Group B than in Groups A and C. Conclusion: Gd-CTPA is recommended to patients who are unsuitable for receiving an iodine-based CTPA. Furthermore, a turbo flash scan could surpass a dual-energy scan without consideration for virtual monoenergetic imaging.
引用
收藏
页码:1310 / 1318
页数:9
相关论文
共 50 条
  • [1] Gadolinium Enhances Dual-energy Computed Tomography Scan of Pulmonary Artery
    An Xie
    Wen-jie Sun
    Yan-feng Zeng
    Peng Liu
    Jian-bin Liu
    Feng Huang
    Current Medical Science, 2022, 42 (6) : 1310 - 1318
  • [2] Navigating the Pulmonary Perfusion Map: Dual-Energy Computed Tomography in Acute Pulmonary Embolism
    Alis, Jonathan
    Latson, Larry A., Jr.
    Haramati, Linda B.
    Shmukler, Anna
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 840 - 849
  • [3] Dual-energy Computed Tomography in Coronary Artery Calcium Scoring
    Abhijith, S.
    Jaseemudheen, M. M.
    HEART VIEWS, 2024, 25 (02): : 74 - 79
  • [4] Dual-energy Computed Tomography Characterization of Solitary Pulmonary Nodules
    Chae, Eun Jin
    Song, Jae-Woo
    Krauss, Bernhard
    Song, Koun-Sik
    Lee, Choong Wook
    Lee, Hyun Joo
    Seo, Joon Beom
    JOURNAL OF THORACIC IMAGING, 2010, 25 (04) : 301 - 310
  • [5] Should Dual-Energy Computed Tomography Pulmonary Angiography Replace Single-Energy Computed Tomography Pulmonary Angiography in Pregnant and Postpartum Patients?
    McDermott, Shaunagh
    Otrakji, Alexi
    Flores, Efren J.
    Kalra, Mannudeep K.
    Shepard, Jo-Anne O.
    Digumarthy, Subba R.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (01) : 25 - 32
  • [6] Vascular Applications of Dual-Energy Computed Tomography
    Rajiah, Prabhakar S.
    Kambadakone, Avinash
    Ananthakrishnan, Lakshmi
    Sutphin, Patrick
    Kalva, Sanjeeva P.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2023, 61 (06) : 1011 - 1029
  • [7] Dual-Energy Computed Tomography in Cardiothoracic Vascular Imaging
    De Santis, Domenico
    Eid, Marwen
    De Cecco, Carlo N.
    Jacobs, Brian E.
    Albrecht, Moritz H.
    Varga-Szemes, Akos
    Tesche, Christian
    Caruso, Damiano
    Laghi, Andrea
    Schoepf, Uwe Joseph
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (04) : 521 - +
  • [8] Dual-Energy Computed Tomography Dose Reduction, Series Reduction, and Contrast Load Reduction in Dual-Energy Computed Tomography
    Parakh, Anushri
    Macri, Francesco
    Sahani, Dushyant
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (04) : 601 - +
  • [9] Dual-Energy Computed Tomography : Technological Considerations
    Chung, Ryan
    Dane, Bari
    Yeh, Benjamin M.
    Morgan, Desiree E.
    Sahani, Dushyant V.
    Kambadakone, Avinash
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2023, 61 (06) : 945 - 961
  • [10] Pediatric Applications of Dual-Energy Computed Tomography
    Pena-Trujillo, Valeria
    Gallo-Bernal, Sebastian
    Tung, Erik L.
    Gee, Michael S.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2023, 61 (06) : 1069 - 1083