H2O2 Biosensor Based on Poly(thionine) and Layer-by-Layer Self-assembly of Carbon Nanotubes and HRP

被引:0
作者
Yang Shaoming [1 ]
Huang Aihua [1 ]
Zha Wenling [1 ]
Wei Zhipeng [1 ]
Zheng Longzhen [1 ]
机构
[1] E China Jiaotong Univ, Sch Basic Sci, Dept Chem & Chem Engn, Nanchang 330013, Peoples R China
关键词
poly(thionine); electro-polymerization; layer-by-layer self-assembly; biosensor; H2O2; HYDROGEN-PEROXIDE; HORSERADISH-PEROXIDASE; AMPEROMETRIC BIOSENSOR; IMMOBILIZATION; NANOPARTICLES;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Carbon nanotubes (CNTs)/horseradish peroxidase (HRP) multilayer reagentless H2O2 biosensor based on poly(thionine) (PTH) mediator was fabricated by the combination of electro-polymerization and layer-by-layer self-assembly method. Electrochemical impedance spectroscopy was used to monitor the layer-by-layer self-assembly process of CNTs/HRP multilayer. The electrochemical behavior of the HRP biosensor was studied by the cyclic voltammetry (CV) and chronoamperometry (I-t). The effect of the number of assembled enzyme layers, work potential, pH value and CNTs were investigated on the response of HRP electrode. The biosensor shows a good linear range of 2.0 X 10(-6)similar to 6.29 X 10(-3) mol/L for H2O2, R=0.998, with a detection limit of 1.0 X 10(-6) mol/L.
引用
收藏
页码:2143 / 2147
页数:5
相关论文
共 25 条
[1]   PHOTOVOLTAIC DETERMINATION OF HYDROGEN-PEROXIDE WITH A BIOPHOTODIODE [J].
AIZAWA, M ;
IKARIYAMA, Y ;
KUNO, H .
ANALYTICAL LETTERS PART B-CLINICAL AND BIOCHEMICAL ANALYSIS, 1984, 17 (07) :555-564
[2]   Amperometric third-generation hydrogen peroxide biosensor based on the immobilization of hemoglobin on multiwall carbon nanotubes and gold colloidal nanoparticles [J].
Chen, Shihong ;
Yuan, Ruo ;
Chai, Yaqin ;
Zhang, Lingyan ;
Wang, Na ;
Li, Xuelian .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (07) :1268-1274
[3]   Electrocatalytic oxidation and sensitive detection of cysteine at layer-by-layer assembled carbon nanotube-modified electrode [J].
Chen, X ;
Yang, Y ;
Ding, MY .
ANALYTICA CHIMICA ACTA, 2006, 557 (1-2) :52-56
[4]   Electrochemical immunoassay for based on polythionine and gold glassy carbon electrodes carbohydrate antigen-125 hollow microspheres modified [J].
Fu, Xiao-Hong .
ELECTROANALYSIS, 2007, 19 (17) :1831-1839
[5]   Electro-oxidative polymerization of phenothiazine dyes into a multilayer-containing carbon nanotube on a glassy carbon electrode for the sensitive and low-potential detection of NADH [J].
Gao, Qiang ;
Sun, Meng ;
Peng, Ping ;
Qi, Honglan ;
Zhang, Chengxiao .
MICROCHIMICA ACTA, 2010, 168 (3-4) :299-307
[6]   ACCURACY OF DETERMINATION OF HYDROGEN PEROXIDE BY CERATE OXIDIMETRY [J].
HURDIS, EC ;
ROMEYN, H .
ANALYTICAL CHEMISTRY, 1954, 26 (02) :320-325
[7]   HELICAL MICROTUBULES OF GRAPHITIC CARBON [J].
IIJIMA, S .
NATURE, 1991, 354 (6348) :56-58
[8]   Chronopotentiometry and Faradaic impedance spectroscopy as methods for signal transduction in immunosensors [J].
Katz, E ;
Alfonta, L ;
Willner, I .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 76 (1-3) :134-141
[9]   Amperometric hydrogen peroxide biosensor based on the immobilization of horseradish peroxidase by carbon-coated iron nanoparticles in combination with chitosan and cross-linking of glutaraldehyde [J].
Lai, Guo-Song ;
Zhang, Hai-Li ;
Han, De-Yan .
MICROCHIMICA ACTA, 2009, 165 (1-2) :159-165
[10]   Electrocatalytic oxidation of the reduced nicotinamide adenine dinucleotide at carbon ionic liquid electrode modified with polythionine/multi-walled carbon nanotubes composite [J].
Mai, Nannan ;
Liu, Xiaoying ;
Zeng, Xiandong ;
Xing, Liang ;
Wei, Wanzhi ;
Luo, Shenglian .
MICROCHIMICA ACTA, 2010, 168 (3-4) :215-220