The retention behaviour of polar compounds on zirconia based stationary phases under hydrophilic interaction liquid chromatography conditions

被引:26
作者
Kucera, R. [1 ]
Kovarikova, P. [1 ]
Klivicky, M. [1 ]
Klimes, J. [1 ]
机构
[1] Charles Univ Prague, Fac Pharm Hradec Kralove, Dept Pharmaceut Chem & Drug Anal, CZ-50005 Hradec Kralove, Czech Republic
关键词
Polybutadiene-coated zirconia; Zirconia; Silica; Hydrophilic interaction liquid chromatography; HILIC; POLYBUTADIENE-COATED ZIRCONIA; SILANE BONDED SILICA; REVERSED-PHASE; EXCHANGE CHROMATOGRAPHY; ELEVATED-TEMPERATURES; MOBILE-PHASE; SEPARATION; SELECTIVITY; OXIDE; COLUMN;
D O I
10.1016/j.chroma.2011.07.100
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The most separations in HILIC mode are performed on silica-based supports. Nevertheless, recently published results have indicated that the metal oxides stationary phases also possess the ability to interact with hydrophilic compounds under HILIC conditions. This paper primarily describes the retention behaviour of model hydrophilic analytes (4-aminobenzene sulfonic acid, 4-aminobenzoic acid, 4-hydroxybenzoic acid, 3,4-diaminobenzoic acid, 3-aminophenol and 3-nitrophenol) on the polybutadine modified zirconia in HILIC. The results were simultaneously compared with a bare zirconia and a silica-based HILIC phase. The mobile phase strength, pH and the column temperature were systematically modified to assess their impact on the retention of model compounds. It was found that the retention of our model hydrophilic analytes on both zirconia phases was mainly governed by adsorption while on the silica-based HILIC phase partitioning was primarily involved. The ability of ligand-exchange interactions of zirconia surface with a carboxylic moiety influenced substantially the response of carboxylic acids on the elevated temperature as well as to the change of the mobile phase pH in contrast to the silica phase. However, no or negligible ligand-exchange interactions were observed for sulfanilic acid. The results of this study clearly demonstrated the ability of modified zirconia phase to retain polar acidic compounds under HILIC conditions, which might substantially enlarge the application area of the zirconia-based stationary phases. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:6981 / 6986
页数:6
相关论文
共 50 条
  • [31] Evaluating the Adsorbed Water Layer on Polar Stationary Phases for Hydrophilic Interaction Chromatography (HILIC)
    Guo, Yong
    Bhalodia, Nidhi
    Fattal, Bassel
    Serris, Ioannis
    SEPARATIONS, 2019, 6 (02)
  • [32] Evaluation of thermally pretreated silica stationary phases under hydrophilic interaction chromatography conditions
    Mignot, Melanie
    Periat, Aurelie
    Peulon-Agasse, Valerie
    Cardinael, Pascal
    Veuthey, Jean-Luc
    Guillarme, Davy
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (09) : 1611 - 1618
  • [33] Evaluation of hydrophilic interaction liquid chromatography stationary phases for analysis of opium alkaloids
    Bagheri, Mohsen
    Taheri, Mohammadreza
    Farhadpour, Mohsen
    Rezadoost, Hassan
    Ghassempour, Alireza
    Aboul-Enein, Hassan Y.
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1511 : 77 - 84
  • [34] Preparation and comparison of three zwitterionic stationary phases for hydrophilic interaction liquid chromatography
    Qiao, Lizhen
    Yu, Chunmei
    Sun, Ruiting
    JOURNAL OF SEPARATION SCIENCE, 2020, 43 (06) : 1071 - 1079
  • [35] Retention of the N-nitrosodiethanolamine by hydrophilic interaction liquid chromatography on different polar columns: mechanism study and optimization
    Abedi, Ghazaleh
    Talebpour, Zahra
    Hosseiny, Arezu
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2024, 21 (09) : 2477 - 2487
  • [36] Stationary and mobile phases in hydrophilic interaction chromatography: a review
    Jandera, Pavel
    ANALYTICA CHIMICA ACTA, 2011, 692 (1-2) : 1 - 25
  • [37] Silica based click amino stationary phase for ion chromatography and hydrophilic interaction liquid chromatography
    Liu, Yajing
    Du, Qing
    Yang, Bingcheng
    Zhang, Feifang
    Chu, Changhu
    Liang, Xinmiao
    ANALYST, 2012, 137 (07) : 1624 - 1628
  • [38] Zirconia based monoliths used in hydrophilic-interaction chromatography for original selectivity of xanthines
    Randon, Jerome
    Huguet, Samuel
    Demesmay, Claire
    Berthod, Alain
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (09) : 1496 - 1500
  • [39] Rapid quantification of imidazolium-based ionic liquids by hydrophilic interaction liquid chromatography: Methodology and an investigation of the retention mechanisms
    Hawkins, Cory A.
    Rud, Anna
    Guthrie, Margaret L.
    Dietz, Mark L.
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1400 : 54 - 64
  • [40] Development and evaluation of new imidazolium-based zwitterionic stationary phases for hydrophilic interaction chromatography
    Qiao, Lizhen
    Dou, Abo
    Shi, Xianzhe
    Li, Hua
    Shan, Yuanhong
    Lu, Xin
    Xu, Guowang
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1286 : 137 - 145