The Transmission Line for the SPIDER experiment

被引:15
作者
Boldrin, Marco [1 ]
De Lorenzi, Antonio [1 ]
Recchia, Mauro [1 ]
Toigo, Vanni [1 ]
Bonicelli, Tullio [2 ]
Simon, Muriel [2 ]
机构
[1] Assoc EURATOM ENEA Fus, Consorzio RFX, I-35127 Padua, Italy
[2] Fus Energy, Barcelona 08019, Spain
关键词
Transmission Line; SPIDER; ITER; Neutral Beam Injector;
D O I
10.1016/j.fusengdes.2010.11.002
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The 100 key Ion Source Test facility - Source for the Production of Ions of Deuterium Extracted from RF plasma (SPIDER) - is aimed to test the full scale prototype of the Ion Source for the ITER 1 MeV Neutral Beam Injector (NB!). The SPIDER facility requires the construction of a High Voltage Deck (HVD) and of a High Voltage Transmission Line (TL) respectively to host the Ion Source Power Supplies system polarized at 100 kV and to carry the power and signal conductors to the beam accelerator. In already existing NBI systems with beam energy above 100 key, the TL is realized with the SF6 Gas Insulated Line technology. In the SPIDER TL case, the presence of a large inner conductor (half meter diameter), would make the pressurized TL a complex and costly component; therefore a free air insulated solution has been proposed. The paper focuses on the design of this TL, which has to host inside the complex high potential (100 kV) inner electrode a number of power and measuring conductors and has to minimize the Electro Magnetic Interferences (EMI) produced by the frequent grids breakdowns. Finite Element (FE) analyses have been performed to verify the configuration from the electrostatic point of view, to evaluate EMI screening effectiveness and to assess the impact of the relatively high thermal dissipation of power conductors located inside the high potential electrode. Moreover, an experimental test campaign has been carried out on a TL mockup to validate the TL electrostatic configuration under DC voltage. Finally, the paper reports on the status of procurement activities for the Transmission Line. (C) 2011 EURATOM. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:754 / 758
页数:5
相关论文
共 7 条
[1]  
[Anonymous], ITER DES REQ GUID DR
[2]  
Bigi M., 2010, 26 S FUS TECHN PORT
[3]  
Claesen R., 1986, P 14 S FUS TECHN AV, P941
[4]   The alternative design concept for the ion source power supply of the ITER neutral beam injector [J].
Gaio, E. ;
Toigo, V. ;
De Lorenzi, A. ;
Piovan, R. ;
Zanotto, L. .
FUSION ENGINEERING AND DESIGN, 2008, 83 (01) :21-29
[5]   HIGH-ENERGY NEGATIVE-ION BASED NEUTRAL BEAM INJECTION SYSTEM FOR JT-60U [J].
KURIYAMA, M ;
AKINO, N ;
ARAKI, M ;
EBISAWA, N ;
HANADA, M ;
INOUE, T ;
KAWAI, M ;
KAZAWA, M ;
KOIZUMI, J ;
KUNIEDA, T ;
MATSUOKA, M ;
MIYAMOTO, K ;
MIZUNO, M ;
MOGAKI, K ;
OHARA, Y ;
OHGA, T ;
OKUMURA, Y ;
OOHARA, H ;
SATOH, F ;
SUZUKI, T ;
TAKAHASHI, S ;
TAKAYASU, T ;
USAMI, H ;
USUI, K ;
WATANABE, K ;
YAMAMOTO, M ;
YAMAZAKI, T .
FUSION ENGINEERING AND DESIGN, 1995, 26 (1-4) :445-453
[6]  
Pesce A., 2010, 26 S FUS TECHN PORT
[7]  