Mechanical behaviour of full unit masonry panels under fire action

被引:17
作者
Andreini, Marco [1 ]
Sassu, Mauro [1 ]
机构
[1] Univ Pisa, Dept Civil Engn, Struct Div, I-56126 Pisa, Italy
关键词
Masonry structures; Fire resistance; M-N domains; Strength fire models;
D O I
10.1016/j.firesaf.2011.07.004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An analytical model is presented to predict the mechanical resistance of full unit masonry panels under combined compressive and bending stress, in the presence of a nominal fire acting on one side. Transitory thermal analysis of the panels is conducted, while accounting for the convection and radiation effects produced by the fire, to determine the collapse conditions for combined compression and bending; five strain field collapse configurations are considered. The numerical analyses, based on data drawn from European regulations EN 1996-1-2, permit the determination of the M-N crushing domains for brick and lightweight aggregate concrete masonry walls, with various thicknesses and exposure times to nominal fire. A numerical example demonstrates the applicability of the model, and a comparison with a set of experimental data on masonry panels demonstrates the efficiency of the model. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:440 / 450
页数:11
相关论文
共 13 条
[1]  
ABRAMS MS, 1971, EFFECT TEMPERATURE C
[2]  
ALNAHHAS F, 2006, APPL THERM ENG
[3]  
ANDERBERG Y, 1976, I TECHNOLOGY B, V54
[4]  
[Anonymous], 1990 EN
[5]  
[Anonymous], 2004, 199112 EN
[6]  
[Anonymous], EFFECT HIGH TEMPERAT
[7]  
Dhanasekar M, 1994, P 10 INT BRICKBLOCK
[8]  
EN, 199612 EN
[9]  
Hahn C, 1998, DEV DETECTION METHOD
[10]  
Nadjai A, 2001, CIVIL AND STRUCTURAL ENGINEERING COMPUTING: 2001, P407, DOI 10.4203/csets.5.16