A novel approach for intra-operative shape acquisition of the tibio-femoral joints using 3D laser scanning in computer assisted orthopaedic surgery

被引:3
作者
Joshi, Shailesh V. [1 ]
Rowe, Philip J. [1 ]
机构
[1] Univ Strathclyde, Dept Biomed Engn, 106 Rottenrow, Glasgow G4 0TD, Lanark, Scotland
关键词
cartilage; image registration; intra-operative 3D imaging; knee arthoplasty; ARTICULAR-CARTILAGE; REGISTRATION; ACCURACY; OSTEOARTHRITIS; MORPHOLOGY; SYSTEM; KNEE; MRI;
D O I
10.1002/rcs.1855
中图分类号
R61 [外科手术学];
学科分类号
摘要
BackgroundImage registration (IR) is an important process of developing a spatial relationship between pre-operative data and the physical patient in the operation theatre. Current IR techniques for Computer Assisted Orthopaedic Surgery (CAOS) are time consuming and costly. There is a need to automate and accelerate this process. MethodsBespoke quick, cost effective, contactless and automated 3D laser scanning techniques based on the DAVID Laserscanner method were designed. 10 cadaveric knee joints were intra-operatively laser scanned and were registered with the pre-operative MRI scans. The results are supported with a concurrent validity study. ResultsThe average absolute errors between scan models were systematically less than 1 mm. Errors on femoral surfaces were higher than tibial surfaces (P<0.05). Additionally, scans acquired through the large exposure produced higher errors than the smaller exposure (P<0.05). ConclusionThis study has provided proof of concept for a novel automated shape acquisition and registration technique for CAOS.
引用
收藏
页数:10
相关论文
共 41 条
[1]  
[Anonymous], 2006, FEATURE BASED REGIST
[2]  
[Anonymous], 2011, RES METHODS DESIGN S
[3]   An algorithmic overview of surface registration techniques for medical imaging [J].
Audette, MA ;
Ferrie, FP ;
Peters, TM .
MEDICAL IMAGE ANALYSIS, 2000, 4 (03) :201-217
[4]  
Banger M., 2013, ANN M INT SOC COMPUT
[5]   Analysis and prediction of edge effects in laser bending [J].
Bao, JC ;
Yao, YL .
JOURNAL OF MANUFACTURING SCIENCE AND ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (01) :53-61
[6]  
Bell A, 2003, J Orthod, V30, P219, DOI 10.1093/ortho/30.3.219
[7]   A METHOD FOR REGISTRATION OF 3-D SHAPES [J].
BESL, PJ ;
MCKAY, ND .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :239-256
[8]  
Bohler W, 2003, INT ARCH PHOTOGRAMME, VXXXIV, pC15
[9]   Quantitative MR imaging using "LiveWire" to measure tibiofemoral articular cartilage thickness [J].
Bowers, M. E. ;
Trinh, N. ;
Tung, G. A. ;
Crisco, J. J. ;
Kimia, B. B. ;
Fleming, B. C. .
OSTEOARTHRITIS AND CARTILAGE, 2008, 16 (10) :1167-1173
[10]   Magnetic resonance imaging (MRI) of articular cartilage in knee osteoarthritis (OA): morphological assessment [J].
Eckstein, F. ;
Cicuttini, Flavia M. ;
Raynauld, J. -P. ;
Waterton, J. C. ;
Peterfy, C. .
OSTEOARTHRITIS AND CARTILAGE, 2006, 14 :A46-A75