Development and validation of highly sensitive method for determination of misoprostol free acid in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry: Application to a clinical pharmacokinetic study

被引:8
|
作者
Bharathi, D. Vijaya [1 ]
Jagadeesh, B. [1 ]
Hotha, Kishore Kumar [1 ]
Patil, Uday [1 ]
Bhushan, Indu [1 ]
机构
[1] Dr Reddys Labs Ltd, Integrated Prod Dev, Bioanalyt Dept, Hyderabad 500072, Andhra Pradesh, India
关键词
Misoprostol free acid; Human plasma; LC-MS/MS; Pharmacokinetics; PROSTAGLANDIN-E1; ANALOG; BIOANALYSIS; ABSORPTION; DRUGS;
D O I
10.1016/j.jchromb.2011.08.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly sensitive, selective and evaporation free SPE extraction, ESI-LC-MS/MS method has been developed for estimation of misoprostol free acid in human plasma using misoprostol acid-d(5) as an internal standard (IS). The analyte was separated using isocratic mobile phase on reverse phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M-H] anions, m/z 367-249 for misoprostol acid and m/z 372-249 for the IS. The total run time was 5.0 min and the elution of misoprostol acid and misoprostol acid-d5 (IS) occurred at 3.6 min. The developed method was validated in human plasma with a lower limit of quantification of 2.5 pg/mL A linear response function was established for the range of concentrations 2.5-1200 pg/mL (r>0.998) for misoprostol acid in human plasma. The intra and inter-day precision values for misoprostol acid met the acceptance as per FDA guidelines. Misoprostol acid was stable in the battery of stability studies viz., bench-top, auto-sampler and freeze/thaw cycles. The developed assay method was applied to an oral pharmacokinetic study in humans. (C) 2011 Published by Elsevier B.V.
引用
收藏
页码:2827 / 2833
页数:7
相关论文
共 50 条
  • [21] Determination of levocetirizine in human plasma by liquid chromatography-electrospray tandem mass spectrometry: Application to a bioequivalence study
    Morita, M. R.
    Berton, D.
    Boldin, R.
    Barros, F. A. P.
    Meurer, E. C.
    Amarante, A. R.
    Campos, D. R.
    Calafatti, S. A.
    Pereira, R.
    Abib, E., Jr.
    Pedrazolli, J., Jr.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 862 (1-2): : 132 - 139
  • [22] Determination of memantine in human plasma by liquid chromatography-electrospray tandem mass spectrometry: Application to a bioequivalence study
    Almeida, A. A.
    Campos, D. R.
    Bernasconi, G.
    Calafatti, S.
    Barros, F. A. P.
    Eberlin, M. N.
    Meurer, E. C.
    Paris, E. G.
    Pedrazzoli, J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 848 (02): : 311 - 316
  • [23] Determination of bevantolol in human plasma using liquid chromatography-electrospray ionization tandem mass spectrometry and its application to a bioequivalence study
    Ren, Li
    Wang, Zheng
    Lou, Yiceng
    Zheng, Lu
    Zheng, Heng
    Yin, Chunping
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 959 : 16 - 21
  • [24] Validated method for determination of bromopride in human plasma by liquid chromatography-electrospray tandem mass spectrometry: application to the bioequivalence study
    Nazare, P
    Massaroti, P
    Duarte, LF
    Campos, DR
    Marchioretto, MAM
    Bernasconi, G
    Calafatti, S
    Barros, FAP
    Meurer, EC
    Pedrazzoli, J
    Moraes, LAB
    JOURNAL OF MASS SPECTROMETRY, 2005, 40 (09): : 1197 - 1202
  • [25] Rapid and sensitive liquid chromatography-electrospray ionization-mass spectrometry method for the determination of eperisone in human plasma: Method and clinical applications
    Ding, L
    Wei, X
    Zhang, SQ
    Sheng, JP
    Zhang, YD
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2004, 42 (05) : 254 - 258
  • [26] Development of sensitive derivatization method for aldosterone in liquid chromatography-electrospray ionization tandem mass spectrometry of corticosteroids
    Yamashita, Kouwa
    Okuyama, Mitsunobu
    Nakagawa, Risa
    Honma, Seijiro
    Satoh, Fumitoshi
    Morimoto, Ryo
    Ito, Sadayoshi
    Takahashi, Madoka
    Numazawa, Mitsuteru
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1200 (02) : 114 - 121
  • [27] Determination of zaltoprofen in human plasma by liquid chromatography with electrospray tandem mass spectrometry: application to a pharmacokinetic study
    Lee, Heon-Woo
    Seo, Ji-Hyung
    Kim, Yong-Won
    Jeong, Seo-Young
    Lee, Kyung-Tae
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (18) : 2675 - 2680
  • [28] Simultaneous determination of metformin and rosiglitazone in human plasma by liquid chromatography/tandem mass spectrometry with electrospray ionization: Application to a pharmacokinetic study
    Zhang, Lu
    Tian, Yuan
    Zhang, Zunjian
    Chen, Yun
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 854 (1-2): : 91 - 98
  • [29] Determination of tetrabromobisphenol A in human serum by liquid chromatography-electrospray ionization tandem mass spectrometry
    Hayama, T
    Yoshida, H
    Onimaru, S
    Yonekura, S
    Kuroki, H
    Todoroki, K
    Nohta, H
    Yamaguchi, M
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 809 (01): : 131 - 136
  • [30] Quantification of zolpidem in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry
    Bhatt, Jignesh
    Jangid, Arvind
    Shetty, Raghavendra
    Shah, Bhavin
    Kambli, Sandeep
    Subbaiah, Gunta
    Singh, Sadhana
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (08) : 736 - 742