Deep learning-based segmentation in prostate radiation therapy using Monte Carlo simulated cone-beam computed tomography

被引:8
作者
Abbani, Nelly [1 ]
Baudier, Thomas [1 ]
Rit, Simon [1 ]
di Franco, Francesca [1 ]
Okoli, Franklin [2 ]
Jaouen, Vincent [2 ]
Tilquin, Florian [3 ]
Barateau, Anais [3 ]
Simon, Antoine [3 ]
de Crevoisier, Renaud [3 ]
Bert, Julien [2 ]
Sarrut, David [1 ]
机构
[1] Univ Claude Bernard Lyon 1, Univ Lyon, INSERM, CNRS,INSA Lyon, Lyon, France
[2] Univ Bretagne Occidentale, INSERM, LaTIM, Brest, France
[3] Univ Rennes, INSERM, CLCC Eugene Marquis, Rennes, France
关键词
cancer; CBCT; deep learning; Monte Carlo simulation; prostate; segmentation; DEFORMABLE IMAGE REGISTRATION; CONTOUR PROPAGATION; SCATTER CORRECTION; CT; ALGORITHM; RADIOTHERAPY;
D O I
10.1002/mp.15946
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Segmenting organs in cone-beam CT (CBCT) images would allow to adapt the radiotherapy based on the organ deformations that may occur between treatment fractions. However, this is a difficult task because of the relative lack of contrast in CBCT images, leading to high inter-observer variability. Deformable image registration (DIR) and deep-learning based automatic segmentation approaches have shown interesting results for this task in the past years. However, they are either sensitive to large organ deformations, or require to train a convolutional neural network (CNN) from a database of delineated CBCT images, which is difficult to do without improvement of image quality. In this work, we propose an alternative approach: to train a CNN (using a deep learning-based segmentation tool called nnU-Net) from a database of artificial CBCT images simulated from planning CT, for which it is easier to obtain the organ contours. Methods Pseudo-CBCT (pCBCT) images were simulated from readily available segmented planning CT images, using the GATE Monte Carlo simulation. CT reference delineations were copied onto the pCBCT, resulting in a database of segmented images used to train the neural network. The studied segmentation contours were: bladder, rectum, and prostate contours. We trained multiple nnU-Net models using different training: (1) segmented real CBCT, (2) pCBCT, (3) segmented real CT and tested on pseudo-CT (pCT) generated from CBCT with cycleGAN, and (4) a combination of (2) and (3). The evaluation was performed on different datasets of segmented CBCT or pCT by comparing predicted segmentations with reference ones thanks to Dice similarity score and Hausdorff distance. A qualitative evaluation was also performed to compare DIR-based and nnU-Net-based segmentations. Results Training with pCBCT was found to lead to comparable results to using real CBCT images. When evaluated on CBCT obtained from the same hospital as the CT images used in the simulation of the pCBCT, the model trained with pCBCT scored mean DSCs of 0.92 +/- 0.05, 0.87 +/- 0.02, and 0.85 +/- 0.04 and mean Hausdorff distance 4.67 +/- 3.01, 3.91 +/- 0.98, and 5.00 +/- 1.32 for the bladder, rectum, and prostate contours respectively, while the model trained with real CBCT scored mean DSCs of 0.91 +/- 0.06, 0.83 +/- 0.07, and 0.81 +/- 0.05 and mean Hausdorff distance 5.62 +/- 3.24, 6.43 +/- 5.11, and 6.19 +/- 1.14 for the bladder, rectum, and prostate contours, respectively. It was also found to outperform models using pCT or a combination of both, except for the prostate contour when tested on a dataset from a different hospital. Moreover, the resulting segmentations demonstrated a clinical acceptability, where 78% of bladder segmentations, 98% of rectum segmentations, and 93% of prostate segmentations required minor or no corrections, and for 76% of the patients, all structures of the patient required minor or no corrections. Conclusion We proposed to use simulated CBCT images to train a nnU-Net segmentation model, avoiding the need to gather complex and time-consuming reference delineations on CBCT images.
引用
收藏
页码:6930 / 6944
页数:15
相关论文
共 50 条
  • [41] Imaging dose from cone beam computed tomography in radiation therapy
    Alaei, Parham
    Spezi, Emiliano
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (07): : 647 - 658
  • [42] Cross-Domain Data Augmentation for Deep-Learning-Based Male Pelvic Organ Segmentation in Cone Beam CT
    Leger, Jean
    Brion, Eliott
    Desbordes, Paul
    De Vleeschouwer, Christophe
    Lee, John A.
    Macq, Benoit
    APPLIED SCIENCES-BASEL, 2020, 10 (03):
  • [43] Deep Learning-Based Internal Target Volume (ITV) Prediction Using Cone-Beam CT Images in Lung Stereotactic Body Radiotherapy
    Li, Zhen
    Zhang, Shujun
    Zhang, Libo
    Li, Ya
    Zheng, Xiangpeng
    Fu, Jie
    Qiu, Jianjian
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2022, 21
  • [44] Imaging dose of cone-beam computed tomography in nanoparticle-enhanced image-guided radiotherapy: A Monte Carlo phantom study
    Mututantri-Bastiyange, Dewmini
    Chow, James C. L.
    AIMS BIOENGINEERING, 2020, 7 (01): : 1 - 11
  • [45] Scatter correction for kilovoltage cone-beam computed tomography (CBCT) images using Monte Carlo simulations - art. no. 614254
    Jarry, G.
    Graham, S. A.
    Jaffray, D. A.
    Moseley, D. J.
    Verhaegen, F.
    Medical Imaging 2006: Physics of Medical Imaging, Pts 1-3, 2006, 6142 : 14254 - 14254
  • [46] Deep Learning Based Projection Domain Metal Segmentation for Metal Artifact Reduction in Cone Beam Computed Tomography
    Agrawal, Harshit
    Hietanen, Ari
    Sarkka, Simo
    IEEE ACCESS, 2023, 11 : 100371 - 100382
  • [47] Deep learning-based enhancement of ultra-low-dose cone-beam CT image using simulated data
    Kim, Sunjung
    Lee, Hyunwoo
    Yi, Won-Jin
    Cho, Min Kook
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [48] A Simple Scatter Reduction Method in Cone-Beam Computed Tomography for Dental and Maxillofacial Applications Based on Monte Carlo Simulation
    Thanasupsombat, Chalinee
    Thongvigitmanee, Saowapak S.
    Aootaphao, Sorapong
    Thajchayapong, Pairash
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [49] Generating missing patient anatomy from partially acquired cone-beam computed tomography images using deep learning: a proof of concept
    Shields, Benjamin
    Ramachandran, Prabhakar
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (03) : 1321 - 1330
  • [50] Characterization of lung tumors motion baseline using cone-beam computed tomography
    Gauthier, Jean-Francois
    Varfalvy, Nicolas
    Tremblay, Daniel
    Cyr, Marc-Francois
    Archambault, Louis
    MEDICAL PHYSICS, 2012, 39 (11) : 7062 - 7070