Study on phase transition and contrast-enhanced imaging of ultrasound-responsive nanodroplets with polymer shells

被引:14
|
作者
Li, Yaqiong [1 ]
Liu, Ruiqing [2 ]
Liu, Luwen [3 ]
Zhang, Ye [3 ]
Sun, Jun [1 ]
Ma, Peizhi [1 ]
Wu, Yuejin [3 ]
Duan, Shaobo [3 ]
Zhang, Lianzhong [3 ]
机构
[1] Henan Univ, Zhengzhou Univ, Henan Prov Peoples Hosp, Sch Clin Med,Peoples Hosp,Dept Pharm, Zhengzhou 450003, Henan, Peoples R China
[2] Henan Univ, Zhengzhou Univ, Henan Prov Peoples Hosp, Sch Clin Med,Peoples Hosp,Dept Intervent Therapy, Zhengzhou 450003, Henan, Peoples R China
[3] Henan Univ, Zhengzhou Univ, Henan Prov Peoples Hosp, Sch Clin Med,Peoples Hosp,Dept Ultrasound, Zhengzhou 450003, Henan, Peoples R China
关键词
Nanodroplets; Ultrasound; Phase transition; Contrast-enhanced imaging; ACOUSTIC DROPLET VAPORIZATION; PERFLUOROCARBON DROPLETS; DRUG-DELIVERY; CAVITATION; NANOPARTICLES; CHEMOTHERAPY; TUMORS; AGENT;
D O I
10.1016/j.colsurfb.2020.110849
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Ultrasound-responsive nanodroplets show great potential in ultrasound diagnosis and targeted tumour therapy due to their unique phase transition properties. However, the mechanism underlying the phase transition and the properties of contrast-enhanced imaging have not been well elucidated, which impedes the development and application of nanodroplets in clinic. Herein, the phase transition of polymeric nanodroplets with a core of perfluoronpentane (PFP) was studied through the measurement of particle size and in vitro/in vivo contrast-enhanced imaging, and imaging performance was further evaluated by introducing intensity analysis of acoustic signals. The average particle size of nanodroplets increased and became polydispersed when heated at 37 degrees C, which may result from vaporization of a portion of nanodroplets. For imaging in vitro, no acoustic signals were observed at 25 degrees C when the mechanical index (MI) varied from 0.08 to 1.0. At 37 degrees C, acoustic signals were observed for MI >= 0.4, and the intensity was stronger for higher MIs. For imaging in mice livers, the nanodroplets showed similar contrast enhancement behaviours with SonoVue (R) at low MI (0.08), which produced strong acoustic signals immediately and were cleared within 10 min. The acoustic signals at high MI (1.0) were weaker but lasted more than 1 h. These results indicated that the phase transition of polymeric nanodroplets could be induced by diagnostic ultrasound, and contrast-enhanced imaging is closely related to particle size, temperature and MI. This study provides a better understanding of phase transition and contrast-enhanced imaging for ultrasound-responsive nanodroplets with polymer shells.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Contrast-enhanced ultrasound as a valuable imaging modality for characterizing testicular lesions
    Yu, Jie
    Jiang, Xin-Hui
    Du, Lian-Fang
    Bai, Min
    Li, Zhao-Jun
    Shi, Qiu-Sheng
    Jiang, Qi
    Li, Fan
    ASIAN JOURNAL OF ANDROLOGY, 2022, 24 (02) : 201 - +
  • [22] Intravascular Targets for Molecular Contrast-Enhanced Ultrasound Imaging
    Moestue, Siver A.
    Gribbestad, Ingrid S.
    Hansen, Rune
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2012, 13 (06): : 6679 - 6697
  • [23] Solid focal liver lesions indeterminate by contrast-enhanced CT or MR imaging: the added diagnostic value of contrast-enhanced ultrasound
    Quaia, Emilio
    ABDOMINAL IMAGING, 2012, 37 (04): : 580 - 590
  • [24] Accuracy of conventional ultrasound, contrast-enhanced ultrasound and dynamic contrast-enhanced magnetic resonance imaging in assessing the size of breast cancer
    Shi, Xian-Quan
    Dong, Yunyun
    Tan, Xiaoqu
    Yang, Peipei
    Wang, Chunmei
    Feng, Wei
    Lin, Yuxuan
    Qian, Linxue
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2022, 82 (02) : 157 - 168
  • [25] CONTRAST-ENHANCED ULTRASOUND IN THE CHARACTERIZATION OF HEPATOCELLULAR CARCINOMAS TREATED BY ABLATION: COMPARISON WITH CONTRAST-ENHANCED MAGNETIC RESONANCE IMAGING
    Qu, Peng
    Yu, Xiaoling
    Liang, Ping
    Cheng, Zhigang
    Han, Zhiyu
    Liu, Fangyi
    Yu, Jie
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (09): : 1571 - 1579
  • [26] Fusion imaging of contrast-enhanced ultrasound and contrast-enhanced CT or MRI before radiofrequency ablation for liver cancers
    Bo, Xiao-Wan
    Xu, Hui-Xiong
    Wang, Dan
    Guo, Le-Hang
    Sun, Li-Ping
    Li, Xiao-Long
    Zhao, Chong-Ke
    He, Ya-Ping
    Liu, Bo-Ji
    Li, Dan-Dan
    Zhang, Kun
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1067):
  • [27] Contrast-enhanced ultrasound (CEUS) and perfusion imaging using VueBox®
    Wiesinger, Isabel
    Jung, Friedrich
    Jung, Ernst Michael
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2021, 78 (01) : 29 - 40
  • [28] Value of contrast-enhanced ultrasound and elastography in imaging of prostate cancer
    Pallwein, Leo
    Mitterberger, Michael
    Gradl, Johann
    Aigner, Friedrich
    Horninger, Wolfgang
    Strasser, Hannes
    Bartsch, Georg
    zur Nedden, Dieter
    Frauscher, Ferdinand
    CURRENT OPINION IN UROLOGY, 2007, 17 (01) : 39 - 47
  • [29] Gas-generating nanoparticles for contrast-enhanced ultrasound imaging
    Sun, In-Cheol
    Emelianov, Stanislav
    NANOSCALE, 2019, 11 (35) : 16235 - 16240
  • [30] Contrast-Enhanced Ultrasound and Elastography Imaging of the Neonatal Brain: A Review
    Bailey, Christopher
    Huisman, Thierry A. G. M.
    de Jong, Robert M.
    Hwang, Misun
    JOURNAL OF NEUROIMAGING, 2017, 27 (05) : 437 - 441