Implementation of eye-lens dosimetry in Poland

被引:1
|
作者
Szumska, Agnieszka [1 ]
Budzanowski, Maciej [1 ]
Milcewicz-Mika, Izabela [1 ]
Kope, Renata [1 ]
机构
[1] Polish Acad Sci, Inst Nucl Phys, PL-31342 Krakow, Poland
关键词
Personnel/individual monitoring; Thermoluminescence; Eye lens doses; INTERVENTIONAL RADIOLOGY; CARDIOLOGY; RADIATION; EXPOSURE; STAFF;
D O I
10.1016/j.radphyschem.2019.108676
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
It has been seven years from the ICRP Statement on tissue reactions containing the recommendations for an equivalent dose limit for the lens of the eye of 20 mSv per year for workers (ICRP, 2012), and has been 7 years since Laboratory of Individual and Environmental Dosimetry (LADIS) introduced in practice eye lens doses measurement. The reduction of the limit for occupational exposure for the lens of the eye needs adequate approaches for eye protection and eye dose monitoring. The most accurate method for monitoring the equivalent dose to the lens of the eye is to measure the personal dose equivalent Hp(3) with a dedicated dosimeter worn as close as practicable to the eye. To measure eye lens doses in terms of this quantity a dosemeter and an appropriate method has been introduced in the largest dosimetry service in Poland. This paper presents historically the introduction of eye lens dosimetry in routine measurements and an analysis of the exposure results of the eye lens dose sl. Results of measurements of Hp(3) from eye lens dose-meters (almost 5000 quarterly readouts), issued in the years 2012-2018 were reported. In measurements EYE-D (TM) dosemeter developed within ORAMED EU project (Vanhavere et al., 2011) and high-sensitivity MCP-N (LiF:Mg, Cu, P) thermoluminescence detectors were used. The frequency distribution of eye lens dose measurements performed using specially dedicated dosemeters, via their Hp(3) operational values, over 3-month periods, after subtraction of natural background in 74% cases are below 0.1 mSv. In the case of the new operational quantity, Hp(3) the number of workers, which exceed the new limit during 7 years monitoring period was 48 (1%). The study showed considerable uncertainties associated with the assessment of eye lens dose from the commonly used whole body dosemeters on the chest in terms of Hp(10) and ring dosemeters on the finger which measures skin doses in terms of Hp(0.07). Therefore, only monitoring of the eyes with specific dosemeters for yearly follow-up can provide accurate annual doses.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] SWELLING AND SHRINKAGE OF BOVINE EYE-LENS CAPSULE AND THEIR EFFECT ON MEMBRANE-PERMEABILITY
    MIYATA, K
    NAKAGAKI, M
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 1978, 98 (06): : 794 - 801
  • [42] 3D TV by eye-lens type electro-holography
    Sato, K
    PRACTICAL HOLOGRAPHY XI AND HOLOGRAPHIC MATERIALS III, 1997, 3011 : 14 - 18
  • [43] Frequency and Diagnostic Implications of Image Artifacts by Eye-Lens Shielding in Head CT
    Schmidt, Stefan A.
    Gruenke, Teresa
    Beer, Meinrad
    Wunderlich, Arthur P.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 212 (03) : 607 - 613
  • [44] Eye-lens bismuth shielding in paediatric head CT: artefact evaluation and reduction
    Maria Raissaki
    Kostas Perisinakis
    John Damilakis
    Nicholas Gourtsoyiannis
    Pediatric Radiology, 2010, 40 : 1748 - 1754
  • [45] EYE-LENS WEIGHT AS AN INDICATOR OF AGE IN ROE DEER (CAPREOLUS-CAPREOLUS)
    HRABE, V
    KOUBEK, P
    FOLIA ZOOLOGICA, 1989, 38 (04) : 299 - 305
  • [47] Possible occurrence of a Fabry-Perot type of interference filter in a fish eye-lens
    Dey, S
    CURRENT SCIENCE, 1997, 72 (11): : 785 - 787
  • [48] QUANTITATIVE INTERPRETATION OF ULTRACENTRIFUGAL AND ELECTROPHORETICAL INVESTIGATIONS ON THE EYE-LENS PROTEIN, ALPHA-CRYSTALLIN
    BON, WF
    RECUEIL DES TRAVAUX CHIMIQUES DES PAYS-BAS-JOURNAL OF THE ROYAL NETHERLANDS CHEMICAL SOCIETY, 1959, 78 (01): : 75 - 82
  • [49] Thermoluminescence measurements of eye-lens dose in a multi-centre stereotactic radiosurgery audit
    Alyahyawi, Amjad
    Dimitriadis, A.
    Jafari, S. M.
    Lohstroh, A.
    Alanazi, A.
    Alsubaie, A.
    Clark, C. H.
    Nisbet, A.
    Bradley, D. A.
    RADIATION PHYSICS AND CHEMISTRY, 2019, 155 : 75 - 81
  • [50] EYE-LENS WEIGHT AS AN INDICATOR OF AGE IN AUSTRALIAN GOATS, CAPRA-HIRCUS L
    HENZELL, R
    AUSTRALIAN WILDLIFE RESEARCH, 1987, 14 (01): : 69 - 79