Concentration and Preservation of Very Low Abundance Biomarkers in Urine, such as Human Growth Hormone (hGH), by Cibacron Blue F3G-A Loaded Hydrogel Particles

被引:45
作者
Fredolini, Claudia [1 ,2 ,3 ]
Meani, Francesco [1 ,4 ]
Reeder, K. Alex [1 ]
Rucker, Sally [1 ]
Patanarut, Alexis [6 ]
Botterell, Palma J. [6 ]
Bishop, Barney [6 ]
Longo, Caterina [1 ,5 ]
Espina, Virginia [1 ]
Petricoin, Emanuel F., III [1 ]
Liotta, Lance A. [1 ]
Luchini, Alessandra [1 ]
机构
[1] George Mason Univ, Ctr Appl Prote & Mol Med, Manassas, VA 20110 USA
[2] S Giovanni Bosco Hosp, Dept Urol, I-10154 Turin, Italy
[3] Univ Turin, Dept Med & Expt Oncol, I-10126 Turin, Italy
[4] Univ Brescia, Dept Gynecol & Obstet, I-25100 Brescia, Italy
[5] Univ Modena & Reggio Emilia, Dept Dermatol & Venereol, I-41100 Modena, Italy
[6] George Mason Univ, Dept Chem & Biochem, Manassas, VA 20110 USA
关键词
Urine proteomics; Cibacron Blue F3G-A; human growth hormone; hydrogel nanoparticles; N-isopropylacrylamide;
D O I
10.1007/s12274-008-8054-z
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Urine is a potential source of diagnostic biomarkers for detection of diseases, and is a very attractive means of non-invasive biospecimen collection. Nonetheless, proteomic measurement in urine is very challenging because diagnostic biomarkers exist in very low concentration (usually below the sensitivity of common immunoassays) and may be subject to rapid degradation. Hydrogel nanoparticles functionalized with Cibacron Blue F3G-A (CB) have been applied to address these challenges for urine biomarker measurement. We chose one of the most difficult low abundance, but medically relevant, hormones in the urine: human growth hormone (hGH). The normal range of hGH in serum is 1 to 10 ng/mL but the urine concentration is suspected to be a thousand times less, well below the detection limit (50 pg/mL) of sensitive clinical hGH immunoassays. We demonstrate that CB particles can capture, preserve and concentrate hGH in urine at physiological salt and urea concentrations, so that hGH can be measured in the linear range of a clinical immunometric assay. Recombinant and cadaveric hGH were captured from synthetic and human urine, concentrated and measured with an Immulite chemiluminescent immunoassay. Values of hGH less than 0.05 ng/mL (the Immulite detection limit) were concentrated to 2 ng/mL, with a urine volume of 1 mL. Dose response studies using 10 mL of urine demonstrated that the concentration of hGH in the particle eluate was linearly dependent on the concentration of hGH in the starting solution, and that all hGH was removed from solution. Thus if the starting urine volume is 100 mL, the detection limit will be 0.1 pg/mL. Urine from a healthy donor whose serum hGH concentration was 1.34 ng/mL was studied in order detect endogenous hGH. Starting from a volume of 33 mL, the particle eluate had an hGH concentration of 58 pg/mL, giving an estimated initial concentration of hGH in urine of 0.175 pg/mL. The nanotechnology described here appears to have the desired precision, accuracy and sensitivity to support large scale clinical studies of urine hGH levels.
引用
收藏
页码:502 / 518
页数:17
相关论文
共 43 条
[1]   DIAGNOSTIC-SIGNIFICANCE OF URINARY GROWTH-HORMONE MEASUREMENTS IN CHILDREN WITH GROWTH FAILURE - CORRELATION BETWEEN SERUM AND URINE GROWTH-HORMONE [J].
ALBINI, CH ;
SOTOS, J ;
SHERMAN, B ;
JOHANSON, A ;
CELNIKER, A ;
HOPWOOD, N ;
QUATTRIN, T ;
MILLS, BJ ;
MACGILLIVRAY, MH .
PEDIATRIC RESEARCH, 1991, 29 (06) :619-622
[2]   Urine proteomics: the present and future of measuring urinary protein components in disease [J].
Barratt, Jonathan ;
Topham, Peter .
CANADIAN MEDICAL ASSOCIATION JOURNAL, 2007, 177 (04) :361-368
[3]   Hormone abuse, in sports: the antidoping perspective [J].
Barroso, Osquel ;
Mazzoni, Irene ;
Rabin, Olivier .
ASIAN JOURNAL OF ANDROLOGY, 2008, 10 (03) :391-402
[4]   Growth hormone assays: current methodologies and their limitations [J].
Bidlingmaier, Martin ;
Strasburger, Christian J. .
PITUITARY, 2007, 10 (02) :115-119
[5]   Enantioseparation of dopa and related compounds by cyclodextrin-modified microemulsion electrokinetic chromatography [J].
Borst, Claudia ;
Holzgrabe, Ulrike .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1204 (02) :191-196
[6]   Urinary growth hormone: a screening test for growth hormone sufficiency [J].
Butt, DA ;
Sochett, EB .
CLINICAL ENDOCRINOLOGY, 1997, 47 (04) :447-454
[7]   Bimodal complexations of steroids with cyclodextrins by a flexible docking algorithm [J].
Cai, WS ;
Yao, XX ;
Shao, XG ;
Pan, ZX .
JOURNAL OF INCLUSION PHENOMENA AND MACROCYCLIC CHEMISTRY, 2005, 51 (1-2) :41-51
[8]  
Carroll MF, 2000, AM FAM PHYSICIAN, V62, P1333
[9]   Novel PVA-based hydrogel microparticles for doxorubicin delivery [J].
Cavalieri, Francesca ;
Chiessi, Ester ;
Villa, Raffaella ;
Vigano, Lucia ;
Zaffaroni, Nadia ;
Telling, Mark F. ;
Paradossi, Gaio .
BIOMACROMOLECULES, 2008, 9 (07) :1967-1973
[10]   Dye-ligand affinity systems [J].
Denizli, A ;
Piskin, E .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2001, 49 (1-3) :391-416