Computer-assisted total-knee arthroplasty.: Comparison of two successive systems.: Learning curve

被引:6
作者
Bove, J. -C. [1 ]
机构
[1] Serv Chirurg Orthoped & Traumatol, F-59600 Maubeuge, France
来源
REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR | 2008年 / 94卷 / 03期
关键词
total-knee arthroplasty; computer-assisted surgery; learning curve;
D O I
10.1016/j.rco.2008.01.002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose of the study. -The increasing popularity of total-knee arthroplasty has led to many technical improvements both in the field of prosthesis design and implanted material and instrumentation. The recent advent of computer-assisted techniques is the fruit of a search for more precision for the bone cuts and better ligament balance. The purpose of the present study was to demonstrate how easy it is to use navigation systems by examining the difficulties encountered by one operator with navigation experience when the material was changed. Material and methods. -The first 30 total-knee arthroplasties implanted with a new navigation system were investigated. Elements specifically related to navigation difficulties were studied. The series was composed of 16 women and 14 men, mean age 65.9 years at the time of surgery (range, 43 to 84). Mean BMI was 30.66 (range, 23.05 to 39.54). All patients were reviewed by the operator using a standard X-ray protocol. Mean follow-up was six months. The 30 arthroplasties were consecutive, with no exclusions excepting revision procedures. Primary or post-traumatic degeneration was the main reason for surgery. This series was compared with two prior series of 30 prostheses each, implanted with a different navigation system. The first 30 and last 30 implantations using the previous navigation system were thus compared in terms of operative time and precision (comparison of postoperative alignment and implant position). The study focused on difficulties encountered when using the new system, on intra- and postoperative complications and on assessment of implant position. Results. -All procedures were totally performed with the navigation system, no interruptions. Operative time was lengthened by an average of 18 min (range, 0 to 45 min). There were no complications specifically related to the navigation system. The position of the implants was assessed in the frontal and sagittal plane on the plain X-rays and with a goniometer. Computed tomography was used to assess femoral component rotation. The overall alignment of the tower limb was within the "ideal" range of 30 in 97% (average 0.1 degrees varus). The position of the femoral implant and the tibial. plate was correct in the frontal and sagittal planes and no internal rotation of the femoral piece was noted on the 27 ct scan studies (mean 1.9 degrees external rotation). Implant accuracy was equivalent to that observed in the series of the last 30 implants using the prior navigation system. The learning curve was shorter. Discussion. -This small series demonstrated the absence of major problems with the new navigation system. The length of the learning curve was acceptable. This study demonstrated that prior experience with navigation is beneficial because the learning curve with the new system was shorter and the accuracy of implantation was equivalent to that achieved with the prior system. Widespread use of computer-assisted surgery should enable continued improvement in ancillary systems in the upcoming years, particularly concerning rotatory position of the femoral implants, which is stilt a problem. Cost containment wilt also be a necessary goal. (c) 2008 Elsevier Masson SAS.
引用
收藏
页码:252 / 260
页数:9
相关论文
共 21 条
  • [1] Barrack RL, 2001, CLIN ORTHOP RELAT R, P46
  • [2] Alignment in total knee arthroplasty -: A comparison of computer-assisted surgery with the conventional technique
    Bäthis, H
    Perlick, L
    Tingart, M
    Lüring, C
    Zurakowski, D
    Grifka, J
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (05): : 682 - 687
  • [3] Computer-assisted knee arthroplasty versus a conventional jig-based technique -: A randomised, prospective trial
    Chauhan, SK
    Scott, RG
    Breidahl, W
    Beaver, RJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (03): : 372 - 377
  • [4] Three-dimensional morphology and kinematics of the distal part of the femur viewed in virtual reality - Part II
    Eckhoff, DG
    Bach, JM
    Spitzer, VM
    Reinig, KD
    Bagur, MM
    Baldini, TH
    Rubinstein, D
    Humphries, S
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A : 97 - 104
  • [5] When computer-assisted knee replacement is the best alternative
    Fehring, Thomas K.
    Mason, J. Bohannon
    Moskal, Joseph
    Pollock, David C.
    Mann, John
    Williams, Vincent J.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (452) : 132 - 136
  • [6] GALAUD B, 2006, REV CHIR ORTHOP S5, V92, P2005
  • [7] Computer-assisted navigation increases precision of component placement in total knee arthroplasty
    Haaker, RG
    Stockheim, M
    Kamp, M
    Proff, G
    Breitenfelder, J
    Ottersbach, A
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (433) : 152 - 159
  • [8] Are systemic emboli reduced in computer-assisted knee surgery? A prospective, randomised, clinical trial
    Kalairajah, Y
    Cossey, AJ
    Verrall, GM
    Ludbrook, G
    Spriggins, AJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (02): : 198 - 202
  • [9] Computer-assisted navigation in TKA -: Where we are and where we are going
    Laskin, Richard S.
    Beksac, Burak
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (452) : 127 - 131
  • [10] Lerat JL, 2006, REV CHIR ORTHOP, V92, P248