Experimental and numerical analysis of solar-absorbing metallic facade panel with embedded heat-pipe-array

被引:11
|
作者
Liu, Wenjie [1 ,2 ]
Chow, Tin-Tai [1 ,2 ]
机构
[1] City Univ Hong Kong, Div Bldg Sci & Technol, Hong Kong, Peoples R China
[2] City Univ Hong Kong, Shenzhen Res Inst, Hong Kong, Peoples R China
关键词
Solar-absorbing facade; Heat-pipe technology; Curtain wall; Solar energy utilization; Sustainable building; SEASON PERFORMANCE; ENERGY-CONSUMPTION; HOT-WATER; OPTIMIZATION; APPLICABILITY; COLLECTOR;
D O I
10.1016/j.apenergy.2020.114736
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The integrative performance of advanced building facade is important for sustainable building development. This paper introduces two solar-absorbing curtain-wall panels with embedded straight-heat-pipe and heat-pipe-ring respectively. Taking advantage of the high thermal conductance of heat pipe, the proposed solar-absorbing aluminum panels can preheat cold water, like for the domestic hot water supply. They also reduce the solar transmission to the indoor space. In hot summer, the dual effect leads to considerable energy saving in both the hot-water and the air-conditioning systems. Comparing with the water-tubing collector panel, the heat-pipe type has wider application by eliminating the water-freezing problem. The conceptual design, prototype construction and computer-model development of these two panels are discussed in this paper. Measurements were taken with the two prototypes installed at an outdoor environmental chamber. Dynamic simulation models were then developed through the control volume finite difference method, and validated with the measured data. The simulation models can be used in advanced building simulation tools for transient thermal performance analysis. Further numerical analysis with these models showed that comparatively, the innovative heat-pipe-ring is the more promising design because of the effective increase in solar absorbing surface area. In the studied warm climate scenarios from summer to winter and from sunny to cloudy conditions, the water heat gain efficiency was estimated from 62.5% to 94.9% in all cases with the glazed panel. The estimated room heat gain/loss as well as the electricity saving performance are also attractive.
引用
收藏
页数:13
相关论文
共 14 条
  • [1] Innovative Prefabricated Wall Panel for Solar Utilization and Energy Efficiency: Building-Integrated Heat Pipe-Embedded System for Cooling-Dominant Zones
    Long, Hui
    Xu, Yangguang
    BUILDINGS, 2025, 15 (04)
  • [2] Experimental study of the thermal characteristics of a heat storage wall with micro-heat pipe array (MHPA) and PCM in solar greenhouse
    Guan, Yong
    Meng, Qi
    Ji, Tianxu
    Hu, Wanling
    Li, Wenlong
    Liu, Tianming
    ENERGY, 2023, 264
  • [3] NUMERICAL MODEL AND EXPERIMENTAL VALIDATION OF THE HEAT TRANSFER IN AIR COOLED SOLAR PHOTOVOLTAIC PANEL
    Ranganathan, Senthil Kumar
    Elumalai, Natarajan
    Natarajan, Puja Priyadharshini
    THERMAL SCIENCE, 2016, 20 : S1071 - S1081
  • [4] A numerical and experimental study of micro-channel heat pipe solar photovoltaics thermal system
    Modjinou, Mawufemo
    Ji, Jie
    Li, Jing
    Yuan, Weiqi
    Zhou, Fan
    APPLIED ENERGY, 2017, 206 : 708 - 722
  • [5] Performance analysis of a prototype solar photovoltaic/wickless heat pipe embedded aluminum curtain wall-heat pump water heating system
    Tomar, Vivek
    Tsang, Ernest Kin W.
    Li, Danny H. W.
    ENERGY CONVERSION AND MANAGEMENT, 2022, 258
  • [6] Performance analysis on a solar concentrating thermoelectric generator using the micro-channel heat pipe array
    Li, Guiqiang
    Zhang, Gan
    He, Wei
    Ji, Jie
    Lv, Song
    Chen, Xiao
    Chen, Hongbing
    ENERGY CONVERSION AND MANAGEMENT, 2016, 112 : 191 - 198
  • [7] Experimental study of the thermal performance for the novel flat plate solar water heater with micro heat pipe array absorber
    Deng, Yuechao
    Zhao, Yaohua
    Quan, Zhenhua
    Zhu, Tingting
    INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY, SHC 2014, 2015, 70 : 41 - 48
  • [8] Experimental study and numerical validation on the effect of inclination angle to the thermal performance of solar heat pipe photovoltaic/thermal system
    Zhang, Tao
    Zheng, Wenjie
    Wang, Liuya
    Yan, Zhiwei
    Hu, Mingke
    ENERGY, 2021, 223
  • [9] Assessment on the Efficiency of an Active Solar Thermal Facade: Study of the Effect of Dynamic Parameters and Experimental Analysis When Coupled/Uncoupled to a Heat Pump
    Elguezabal, Peru
    Lopez, Alex
    Maria Blanco, Jesus
    Antonio Chica, Jose
    ENERGIES, 2020, 13 (03)
  • [10] EXPERIMENTAL ANALYSIS OF A SOLAR DESALINATION SYSTEM WITH GRAPHENE NANOPLATELET-EMBEDDED LATENT HEAT THERMAL ENERGY STORAGE UNIT
    Sirin, Ceylin
    Selimefendigil, Fatih