Pulse-power integrated-decay technique for the measurement of thermal conductivity

被引:25
作者
Kharalkar, Nachiket M. [1 ]
Hayes, Linda J. [2 ]
Valvano, Jonathan W. [1 ]
机构
[1] Univ Texas Austin, Dept Elect & Comp Engn, Austin, TX 78712 USA
[2] Univ Texas Austin, Dept Aerosp Engn & Engn Mech, Austin, TX 78712 USA
关键词
3D finite element modeling; thermal conductivity; instrumentation; self-heated thermistor; bioheat transfer;
D O I
10.1088/0957-0233/19/7/075104
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A pulse-power integrated-decay technique for the measurement of thermal conductivity of biological tissues is presented. A self-heated thermistor probe is used to deliver heat and also to measure the temperature response. Three-dimensional finite element analyses are used in this paper to design and optimize the technique. The thermal conductivity measurements from the computer simulations were in close accordance with the experimental data. An empirical calibration process, performed in glycerol and agar-gelled water, provides accurate thermal conductivity measurements. An accuracy analysis evaluated multiple experimental protocols using three solutions of known thermal properties. The results indicate that the thermal decay technique protocol had better accuracy than the constant temperature heating techniques. In vitro measurements demonstrate the variability of tissue thermal conductivity, and the need to perform direct measurements for tissues of interest. The factors that may introduce error in the experimental data are (i) poor thermal/physical contact between the thermistor probe and tissue sample, (ii) water loss from tissue during the course of experimentation and (iii) temperature stability.
引用
收藏
页数:10
相关论文
共 23 条
[1]   SELF-HEATED THERMISTOR MEASUREMENTS OF PERFUSION [J].
ANDERSON, GT ;
VALVANO, JW ;
SANTOS, RR .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (09) :877-885
[2]   A SMALL ARTERY HEAT-TRANSFER MODEL FOR SELF-HEATED THERMISTOR MEASUREMENTS OF PERFUSION IN THE KIDNEY CORTEX [J].
ANDERSON, GT ;
VALVANO, JW .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1994, 116 (01) :71-78
[3]   A SENSITIVITY ANALYSIS OF THE THERMAL PULSE DECAY METHOD FOR MEASUREMENT OF LOCAL TISSUE CONDUCTIVITY AND BLOOD PERFUSION [J].
ARKIN, H ;
HOLMES, KR ;
CHEN, MM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1986, 108 (01) :54-58
[4]   A TECHNIQUE FOR MEASURING THE THERMAL-CONDUCTIVITY AND EVALUATING THE APPARENT CONDUCTIVITY CONCEPT IN BIOMATERIALS [J].
ARKIN, H ;
HOLMES, KR ;
CHEN, MM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1989, 111 (04) :276-282
[5]   Thermophysical properties of swine myocardium [J].
Bhavaraju, NC ;
Valvano, JW .
INTERNATIONAL JOURNAL OF THERMOPHYSICS, 1999, 20 (02) :665-676
[6]   Measurement of directional thermal properties of biomaterials [J].
Bhavaraju, NC ;
Cao, H ;
Yuan, DY ;
Valvano, JW ;
Webster, JG .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (02) :261-267
[7]   NEW TECHNIQUE UTILIZING THERMISTOR PROBES FOR MEASUREMENT OF THERMAL-PROPERTIES OF BIOMATERIALS [J].
BOWMAN, HF ;
BALASUBRAMANIAM, TA .
CRYOBIOLOGY, 1976, 13 (05) :572-580
[8]   PULSE-DECAY METHOD FOR MEASURING THE THERMAL-CONDUCTIVITY OF LIVING TISSUES [J].
CHEN, MM ;
HOLMES, KR ;
RUPINSKAS, V .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1981, 103 (04) :253-260
[9]  
CHEN YJ, 1992, COMP CONSTANT DELTA, P64
[10]   Tissue thermal conductivity by magnetic resonance thermometry and focused ultrasound heating [J].
Cheng, HLM ;
Plewes, DB .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (05) :598-609