Bias field correction for improved compressed sensing reconstruction in parallel magnetic resonance imaging

被引:3
|
作者
Wang, Fang [1 ]
Fang, Lei [1 ]
Peng, Xuehua [1 ]
Wu, Min [1 ]
Wang, Wenzhi [1 ]
Zhang, Wenhan [1 ]
Zhu, Baiqu [1 ]
Wan, Miao [1 ]
Hu, Xin [1 ]
Shao, Jianbo [1 ]
机构
[1] Huazhong Univ Sci & Technol, Med Imaging Ctr, Tongji Med Coll, Wuhan Childrens Hosp, Wuhan, Peoples R China
关键词
Bias field correction; Compressed sensing; Parallel imaging; Magnetic resonance imaging; MRI; COIL; ALGORITHM;
D O I
10.1007/s11760-020-01721-4
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Parallel imaging and compressed sensing (PICS) may accelerate magnetic resonance imaging (MRI) acquisition with advanced reconstruction algorithms from under-sampled data set. However, bias field effects are often present in reconstructed MRI images due to hardware limitation and object property, which might lead to reconstruction imperfection with conventional PICS reconstruction due to altered image sparsity. In this paper, the MR signal bias field effects is modeled, and it was found that the bias field effects would induce reconstruction artifacts in the low-signal-intensity area. Then it was proposed to add a bias correction step into the PICS reconstruction framework to improve the reconstruction, and the proposed method was evaluated the proposed method via both simulation and in vivo study. It was then shown that the proposed method leads to improved image reconstruction in the low-signal-intensity area, with little extra computational effort needed compared to standard PICS reconstruction. This method could be readily extended to other signal processing area where the signal inhomogeneity problem is present and signal sparsity is exploited.
引用
收藏
页码:687 / 693
页数:7
相关论文
共 50 条
  • [31] Neural Architecture Search for compressed sensing Magnetic Resonance image reconstruction
    Yan J.
    Chen S.
    Zhang Y.
    Li X.
    Computerized Medical Imaging and Graphics, 2020, 85
  • [32] Efficient Blind Compressed Sensing Using Sparsifying Transforms with Convergence Guarantees and Application to Magnetic Resonance Imaging
    Ravishankar, Saiprasad
    Bresler, Yoram
    SIAM JOURNAL ON IMAGING SCIENCES, 2015, 8 (04): : 2519 - 2557
  • [33] Magnetic resonance image reconstruction using fast interpolated compressed sensing
    Datta S.
    Deka B.
    Journal of Optics (India), 2018, 47 (02): : 154 - 165
  • [34] Neural Architecture Search for compressed sensing Magnetic Resonance image reconstruction
    Yan, Jiangpeng
    Chen, Shou
    Zhang, Yongbing
    Li, Xiu
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2020, 85
  • [35] Field inhomogeneity correction based on gridding reconstruction for magnetic resonance imaging
    Eggers, Holger
    Knopp, Tobias
    Potts, Daniel
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2007, 26 (03) : 374 - 384
  • [36] Compressed sensing sparse reconstruction for coherent field imaging
    曹蓓
    罗秀娟
    张羽
    刘辉
    陈明徕
    Chinese Physics B, 2016, 25 (04) : 83 - 88
  • [37] Accelerated two-dimensional cine DENSE cardiovascular magnetic resonance using compressed sensing and parallel imaging
    Xiao Chen
    Yang Yang
    Xiaoying Cai
    Daniel A. Auger
    Craig H. Meyer
    Michael Salerno
    Frederick H. Epstein
    Journal of Cardiovascular Magnetic Resonance, 18
  • [38] Exponential Wavelet Iterative Shrinkage Thresholding Algorithm for compressed sensing magnetic resonance imaging
    Zhang, Yudong
    Dong, Zhengchao
    Phillips, Preetha
    Wang, Shuihua
    Ji, Genlin
    Yang, Jiquan
    INFORMATION SCIENCES, 2015, 322 : 115 - 132
  • [39] Improved Parallel Magnetic Resonance Imaging Reconstruction with Sampling based on Normal Distribution
    Han, Jijie
    Shen, Xingyu
    Zhang, Yulong
    Huang, Zeqiang
    Sheng, Jinhua
    JOURNAL OF IMAGING SCIENCE AND TECHNOLOGY, 2023, 67 (01)
  • [40] High-Resolution Magnetic Resonance Imaging Using Compressed Sensing for Intracranial and Extracranial Arteries: Comparison with Conventional Parallel Imaging
    Suh, Chong Hyun
    Jung, Seung Chai
    Lee, Ho Beom
    Cho, Se Jin
    KOREAN JOURNAL OF RADIOLOGY, 2019, 20 (03) : 487 - 497