Application of a new mathematical function for describing chromatographic peaks

被引:32
作者
Pap, TL [1 ]
Pápai, Z [1 ]
机构
[1] Univ Veszprem, Inst Analyt Chem, H-8201 Veszprem, Hungary
关键词
curve fitting; peak asymmetry; signal processing;
D O I
10.1016/S0021-9673(01)01163-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Curve fitting seems to be one of the best methods for the evaluation of chromatographic signals. As it is known, in this case mathematical function is fitted to digitized measured points. The most important task is to find the best mathematical function, which corresponds perfectly to the peak shape, and then to determine the parameters of the equation using a computerized least-squares method of approximation. In this work, a new mathematical function was sought for with the purpose of describing different chromatographic signals and it was fitted to the digitized measured points. The fitted curve is suitable for a quick evaluation of chromatographic information, noise filtering and correction of baseline drift. The fitting of gas chromatographic and high-performance liquid chromatographic signals were completed. The mathematical function, the generated chromatographic curves, the application of the function for describing real signals and the fitting process will be demonstrated in this study. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:53 / 60
页数:8
相关论文
共 33 条
[1]   EFFECT OF BASELINE ERRORS ON THE CALCULATION OF STATISTICAL MOMENTS OF TAILED CHROMATOGRAPHIC PEAKS [J].
ANDERSON, DJ ;
WALTERS, RR .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1984, 22 (08) :353-359
[2]  
BAUDISCH J, 1970, CHROMATOGRAPHIA, V3, P469
[4]   STATISTICAL MOMENT ANALYSIS AND DECONVOLUTION OF OVERLAPPING CHROMATOGRAPHIC PEAKS [J].
CAI, CP ;
WU, NS .
CHROMATOGRAPHIA, 1991, 31 (11-12) :595-599
[5]  
Crilly P. B., 1987, J CHEMOMETR, V1, P79
[6]   AN EVALUATION OF JANSSON METHOD TO DECONVOLVE OVERLAPPED GAS-CHROMATOGRAPHIC PEAKS [J].
CRILLY, PB .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1988, 93 (03) :413-416
[7]  
CRILLY PB, 1987, J CHEMOMETR, V1, P175
[8]   QUANTITATIVE COMPUTER RESOLUTION OF SEVERELY OVERLAPPING LIQUID-CHROMATOGRAPHIC PEAKS [J].
DALLURA, NJ ;
JUVET, RS .
JOURNAL OF CHROMATOGRAPHY, 1982, 239 (APR) :439-449
[9]   ORIGIN AND CHARACTERIZATION OF DEPARTURES FROM THE STATISTICAL-MODEL OF COMPONENT-PEAK OVERLAP IN CHROMATOGRAPHY [J].
DAVIS, JM ;
GIDDINGS, JC .
JOURNAL OF CHROMATOGRAPHY, 1984, 289 (APR) :277-298
[10]  
DEGEN J, 1985, LABOR PRAXIS, V9, P317