Improved Model Predictive Control for H-bridge Cascaded STATCOM

被引:0
作者
Xu Rong [1 ]
Yu Yong [1 ]
Wu Jian [1 ]
Yang Rongfeng [1 ]
Xu Dianguo [1 ]
Chen He [1 ]
Yu Yannan [1 ]
Ni Ronggang [1 ]
机构
[1] Harbin Inst Technol, Dept Elect Engn, Harbin, Peoples R China
来源
2015 9TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND ECCE ASIA (ICPE-ECCE ASIA) | 2015年
关键词
H-bridge cascaded; static synchronous compensator; model predictive control; repetitive control; POWER; PERFORMANCE; DESIGN;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
H-bridge cascaded static synchronous compensator (STATCOM) is often used to compensate the harmonic and reactive current derived from non-linear load. In order to improve the performance of STATCOM, an improved model predictive control (MPC) method is put forward in this paper. In the proposed MPC, the difference equations which are derived from the transfer functions of controlling variables and controlled variables in STATCOM are used as the predictive control model, the error between the output of STATCOM and predictive model is used to design feedback correction controller and rolling optimization controller. Meanwhile, the introduced repetitive controller is used to eliminate the inherent steady error. The actual H-bridge cascaded STATCOM is constructed and a series of verification tests are executed. The experimental results prove that the output voltage and current of H-bridge cascaded STATCOM with the proposed MPC have smaller distortion and better sinusoidal shape than those of the traditional Proportion Integral (PI) control. Moreover, the performance of H-bridge cascaded STATCOM is great in high power experiment.
引用
收藏
页码:2545 / 2550
页数:6
相关论文
共 15 条
[1]   New trends in active filters for power conditioning [J].
Akagi, H .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1996, 32 (06) :1312-1322
[2]   Control and performance of a transformerless cascade PWM STATCOM with star configuration [J].
Akagi, Hirofumi ;
Inoue, Shigenori ;
Yoshii, Tsurugi .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2007, 43 (04) :1041-1049
[3]   A series active power filter based on a sinusoidal current-controlled voltage-source inverter [J].
Dixon, JW ;
Venegas, G ;
Moran, LA .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1997, 44 (05) :612-620
[4]  
Ganesh SNV, 2009, INT J ELEC POWER, V3, P208
[5]   A linear decoupling multiple-loops control scheme applied to a three-phase series active power filter for voltage harmonic cancellation and reactive power compensation [J].
Kanaan, HY ;
Al-Haddad, K .
2004 11TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER, 2004, :299-304
[6]  
Kumar S, 2007, AUSTRALAS PLANT DIS, V2, P7, DOI 10.1071/DN07004
[7]   Design of a Self-Tuning PI Controller for a STATCOM Using Particle Swarm Optimization [J].
Liu, Chien-Hung ;
Hsu, Yuan-Yih .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (02) :702-715
[8]   A proportional-integrator type adaptive critic design-based neurocontroller for a static compensator in a multimachine power system [J].
Mohagheghi, Salman ;
del Valle, Yamille ;
Venayagamoorthy, Ganesh Kumar ;
Harley, Ronald G. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2007, 54 (01) :86-96
[9]  
Ned Mohan T.M.U, 1995, POWER ELECT CONVERTE
[10]   Two control schemes to enhance the dynamic performance of the STATCOM and SSSC [J].
Norouzi, AH ;
Sharaf, AM .
IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (01) :435-442